TECHNINĖS VANDENS ŠILDYTUVŲ CHARAKTERISTIKOS

Tipas

GBF 50

GBF 80

GBF 100

GBF 120

GBF 150

Modelis

GBFU 50 

EDD/V6

GBFU 80 

EDD/V6

GBFU 100 

EDD/V6

GBFU 120 

EDD/V6

GBFU E150 

EDD/V6

Tūris                                     [ l ]

50

80

100

120

150

Nominalus slėgis            [ MPa ]

0,6

Svoris tuščio / pripildyto    [ kg ]

24/74

30/110

34/134

38/158

44/194

Antikorozinė bako apsauga                                   

emaliuotas/ Mg anodas

Kaitinimo elemento galingumas   

                                          [ W ]

2000

Poèet a výkon ohrievacích 

telies                                  [ W ]

2 x 1000

Įtampa                               [ V~ ]

230

Apsaugos klasė 

I

Apsaugos laipsnis

IP 25 

Sušildymo iki 75°C laikas

1) 

          

                                         [val.]

1

55

3

05

3

55

4

35

5

45

Sumaišyto iki 40°C vandens kie

kis                                    [ l ]

96/80

151/130

199/174

238/210

296/260

Šilumos nuostoliai

2)

                                          

 [ KWh per 24h ]

1,32/1,45

1,85/2,10

2,20/2,45

2,60/2,90

3,20/3,60

1) Vandens sušildymo laikas skaičiuojamas, kai įtekančio šalto vandens temperatūra 10°C.

2)  Šilumos  nuostoliai  skaičiuojami  kai  šildytuve  palaikoma  pastovi  65  0C  temperatūra,  kai  aplinkos 

temperatūra siekia 20°C. Matavimai atlikti pagal EN 60379.

PRIJUNGIMAS PRIE VANDENTIEKIO TINKLO

Vandens privedimo ir karšto vandens nuvedimo antgaliai pažymėti skirtingomis spalvomis : 

mėlynas-šaltas vanduo, raudonas-karštas.

Vandens  šildytuvas  prie  vandentiekio  tinklo  gali  jungtis  dvejopai.  Uždara  (kaupiamoji) 

vandens pajungimo sistema aprūpina vandeniu kelis vartojimo taškus, o atvira (pratekanti) 

– tik viename taške. Priklausomai nuo pasirinktos sistemos turi būti montuojami atatinkami 

vandens maišytuvai. Atviroje vandens pajungimo sistemoje prieš šildytuvą būtina pastatyti 

atbulinį  vožtuvą,kuris  neleis  karštam  vandeniui  patekti  į  šalto  vandens  vamzdį.  Tokioje 

sistemoje reikia naudoti pratekančio srauto maišytuvą. Vandens šildytuve dėl temperatūros 

padidėjimo, keičiasi vandens tūris. Dėl šios priežasties gali iš aukščiau minėto maišytuvo gali 

lašėti vanduo. Nesistenkite sustabdyti vandens stipriai užsukdami kraną, nes galite pažeisti 

maišytuvą.  Apsauginio vožtuvo išvadas privalo turėti išėjimą į atmosferos slėgį.

Uždaroje  vandens  pajungimo  sistemoje  būtina  naudoti  maišytuvus  vandens  paėmimo 

taškuose. Ant šalto vandens padavimo vamzdžio būtina pastatyti apsauginį/atbulinį vožtuvą, 

kuris nustatytas 0,1 MPa (1 bar) slėgiui arba apsauginę grupę, kuri apsaugotų apsaugotų 

nuo viršslėgio susidarymo bake.  Vandeniui šylant, slėgis šildytuve kyla iki nustatyto 0,1 MPa 

(1 bar). Vandens perteklius gali lašėti iš apsauginio vožtuvo angos, todėl rekomenduojama 

nuo  apsauginio  vožtuvo  iki  nuotėkynes  nuvesti  lankstų  vamzdelį  ar  šlangą.  Ji  turėtų  būti 

nukreipta tiesiai žemyn ir būtų apsaugota nuo  užšalimo. 

Jei esama vandentiekio sistema neleidþia leisti varvanèio vandens ið gráþtamojo apsauginio 

voþtuvo á kanalizacijos vamzdá, Jûs galite iðvengti varvëjimo, suinstaliuodami 3 litrø talpos 

rezervuarà ant boilerio vandens áleidimo vamzdþio.

Kad apsauginis vožtuvas dirbtų teisingai, turite jį patys periodiškai tikrinti. Kad patikrintumëte 

LIT

Summary of Contents for GBFU 100 EDD/V6

Page 1: ...GBFU 50 150EDD V6...

Page 2: ...2...

Page 3: ...3 Instructions for use 16 Instrukcij 22 Instrukcija 28 4 10...

Page 4: ...4 8 GBFU 50EDD V6 GBFU 80 EDD V6 GBFU 100 EDD V6 GBFU 120 EDD V6 GBFU 150 EDD V6 A 583 803 948 1103 1318 B 365 565 715 865 1065 C 185 205 200 205 220 D 145 345 495 645 845 UA...

Page 5: ...EDD V6 GBFU 120 EDD V6 GBFU E150 EDD V6 50 80 100 120 150 0 6 24 74 30 110 34 134 38 158 44 194 2000 2 x 1000 230 I IP 25 75 1 155 305 355 435 545 40 96 80 151 130 199 174 238 210 296 260 2 24 1 32 1...

Page 6: ...6 1 2 3 4 5 H T 1 5 2 1 2 3 1000 5 L N 35 C 75 C 1 C 1 C UA...

Page 7: ...7 2 7 C 55 C 35 C 75 C 1 C 7 C 55 C 55 C 35 C UA...

Page 8: ...8 1 C 3 Mg LED 0 C o 75 C 0 C 75 C E1 E2 E3 E4 UA...

Page 9: ...9 E5 100 C 7 C UA...

Page 10: ...c o IEC 60364 7 701 VDE 0100 701 K c 8 GBFU 50EDD V6 GBFU 80 EDD V6 GBFU 100 EDD V6 GBFU 120 EDD V6 GBFU 150 EDD V6 A 583 803 948 1103 1318 B 365 565 715 865 1065 C 185 205 200 205 220 D 145 345 495 6...

Page 11: ...V6 GBFU 120 EDD V6 GBFU E150 EDD V6 50 80 100 120 150 0 6 24 74 30 110 34 134 38 158 44 194 Mg 2000 2 x 1000 230 I IP 25 75 C1 155 305 355 435 545 40 C 96 80 151 130 199 174 238 210 296 260 2 24 1 32...

Page 12: ...12 c B c 3 1 2 3 4 5 K 1 5 2 H05VV F 3G1 5 2 1 2 1000 5 L N RUS...

Page 13: ...13 35 C 75 C 2s 7 55 C 35 C 75 C 1 C 7 C RUS...

Page 14: ...14 55 C 35 C 1 C Mg 0 C 75 C 0 C 75 C E1 RUS...

Page 15: ...15 E2 E3 E4 E5 100 C ry c o ry a RUS...

Page 16: ...must be carried out by qualified staff All repairs and maintenance work within the water heater e g lime removal or inspection replacement of the protective anti corrosion anode must be carried out by...

Page 17: ...he open circuit gravity system enables a single point of use only The mixer taps must also be purchased in accordance with the selected installation mode The open circuit gravity system requires the i...

Page 18: ...without reduction valve if the pressure in the network is lower than 0 5 MPa 5 bar If the pressure exceeds 0 5 MPa 5 bar a reduction valve must be installed Prior to the electric connection the water...

Page 19: ...hows the current temperature of water in water heater OPERATION CONTROL The heater is switched ON and OFF by pressing the key for 2s Continue pressing the key and select the three operating modes prot...

Page 20: ...lamp the lamp is off anode is active the lamp is on anode may be worn out Warning When the water heater is out of use for longer period of time the signal lamp may indicate that the Mg anode is worn...

Page 21: ...n the hot water on the connected mixer tap After discharging through the inlet pipe there is still some water left in the water heater The remaining water will be discharged after removing the heating...

Page 22: ...orizuota tarnyba ar galiotas specialistas Garantin ir pogarantin aptarnavim ir remont nuovir pa alinim antikorozinio anodo patikrinim ar pakeitim gali atlikti tik gamintojo galiota serviso tarnyba MON...

Page 23: ...ke Priklausomai nuo pasirinktos sistemos turi b ti montuojami atatinkami vandens mai ytuvai Atviroje vandens pajungimo sistemoje prie ildytuv b tina pastatyti atbulin vo tuv kuris neleis kar tam vande...

Page 24: ...kti kar to vandens padavimo iaup ildytuvas bus pilnai u pildytas kai i kar to vandens iaupo prad s b gti vanduo PAJUNGIMAS PRIE ELEKTROS TINKLO D mesio is renginys skirtas prijungimui prie kintamos sr...

Page 25: ...at r ildytuve VALDYMAS ildytuvas jungiamas arba i jungiamas paspaudus mygtuk ilgiau nei 2 s Spaudydami programin mygtuk pasirenkame tarp trij galimybi apsaugos prie vandens u alim pasirinkimas i ankst...

Page 26: ...lin lemput vie ia kaitinimo elementas neveikia kontrolin lemput ne vie ia Mg anodo veikimas su alia kontroline lempute kontrolin lemput ne vie ia anodas veikia kontrolin lemput vie ia anodas gali b ti...

Page 27: ...jungti i elektros tinklo ir tada jungti ilto vandens ranken l ant prijungto mai ytuvo I tu tinus ildytuv per nutekam j vamzd ildytuve lieka nedidelis kiekis vandens kuris i teka nu mus ildytuvo priju...

Page 28: ...un densvadam dr kst tikai pilnvarots speci lists Iek jo ier u apkalpo anu katlakmens no em anu p rbaudi vai pretkorozijas aizsardz bas anoda nomai u ar dr kst veikt tikai pilnvarots servisa dienests...

Page 29: ...ist mas Atkl taj caurteces sist m pirms dens sild t ja j uzst da pretv rsts kas nov rs s dens nopl di no katla gad jum ja densvad neb s dens Izmantojot t du piesl g anas sist mu j uzst da caurteces ma...

Page 30: ...ju elektrot klam tas oblig ti j piepilda ar deni Pie pirm s uzpild anas pagrieziet karst dens rokturi uz mais t ja Sild t js ir piepild ts kad dens s k tec t no mais t ja izpl des caurules PIESL G AN...

Page 31: ...s un izsl gts nospie ot tausti u un turot to nospiestu 2s Turpiniet nospiest tausti u un izv lieties tr s darb bas re mus Aizsardz ba pret sald anu r pn c iestat ta dens temperat ra ir noregul ta l dz...

Page 32: ...ta anoda ir akt va Lampa ir iesl gta anoda var b t izdilusi Uzman bu Kad dens sild t js nav izmantots ilg ku laiku sign llampa var liecin t ka Mg anoda ir izdilusi neskatoties uz to ka Mg anoda joproj...

Page 33: ...sild t ja apak jo atloku dens sild t ja r jas da as j t ra ar v ju mazg anas l dzek a dumu Nek d gad jum neizmantojiet nek dus din t jus un agres vas t r anas vielas Ieteicam regul ri veikt dens sild...

Page 34: ...34...

Page 35: ...35...

Page 36: ...03 2010 270067...

Reviews: