61
586310
Gas type, pressure
Oven burner
Infra burner
max
min
Natural gas H
Wo=45,7÷54,7 MJ/ m
3
,
Natural gas E,
Natural gas E+
Wo=40,9÷54,7 MJ/m
3
G20,
p=20mbar
Nominal heat load
(kW)
3
0,8
2,2
Consumption (l/h)
286
76
210
Nozzle type (1/100
mm)
117
33
108
Nozzle ID
568171
568173
Liquefied gas
3+, B/P
Wo=72,9÷87,3MJ/m
3
G30
p=30 mbar
Nominal heat load
(kW)
3
0,8
2,2
Consumption
(g/h)
218
58
160
Nozzle type (1/100
mm)
82
33
75
Nozzle ID
568177
568178
• Regulation screws for liquefi ed gas are installed and set in factory to the gas type for
which the factory default settings apply.
• When modifying the appliance for use with a diff erent type of gas, the regulation screw
has to be tightened or undone to set the required gas fl ow (do not undo the regulation
screw by more than 1.5 turns).
Burner power is indicated by observing the upper Hs caloric value.
Connection to gas supply and adjustment to a different type of
gas may only be carried out by an expert authorized by the gas
distributor or an authorized service technician!