III Technical data
Characteristics
Hood type
DVG 8640 X / DVG 6640 AX
Supply voltage
AC 230V 50Hz
Fan motor
1
Lighting
2 x 20 W
Number of grease filters
1
Fan speeds
4
Width [cm]
80
Depth [cm]
Height [cm]
Outlet [ø mm]
150 or 120
Capacity [m
3
/h]
Max 700
Power consumption [W]
240
Noise level [dBA]
Max 54
Operational mode
Extractor or absorber
Colour
INOX stainless steel, mat
IV Operating conditions
1. SAFETY PRECAUTION
Take care when the cooker hood is operating simultaneously with an open fireplace or burner that depend
on the air in the environment and are supplied
by other than electrical energy, as the cooker hood removes the air from the environment which a burner or
fireplace need for combustion. The negative pressure in the environment must not exceed 4Pa (4x10 -5
bar). Provide adequate ventilation in the environment for a safe operation of the cooker hood. Follow the
local laws applicable for exter nal air evacuation.
2. The kitchen hood was designed for removal of kitchen fumes to the outside. It should be connected to an
appropriate ventilation duct (do not connect the hood to any chimney, smoke or flue-gas ducts which are in
use).
3. The device shall be installed at the distance of at least 450 mm above the working top of an electric
cooker and 550 mm - of a gas cooker.
4. Do not leave open flame under the hood. When removing pots from the burners set the flame to its
minimum level.
5. Any food cooked in fat shall be constantly monitored, since overheated fat can ignite very easily.
6. The grease filter of your kitchen hood should be cleaned at least every 2 months, because a filter soaked
with grease becomes easily flammable.
7. Pull the plug of the power cord from a wall socket before any cleaning, filter replacement or repair
operation.
8. If any other non-electric devices are used in the same room as the hood (e.g. liquid fuel ovens, flow-
through or volumetric water heaters), it is necessary to provide appropriate ventilation (air supply). Safe
operation is possible when during simultaneous operation of the hood and combustion devices dependent
on air supply the negative pressure of not more than 0.004 milibar is maintained at the location of these
devices inside the room (this point does not apply when the hood is used as an odour absorber).
9. When connecting to 230V power supply network use an electric socket in working order