background image

8

After connecting the gas hob, check the joints for any leaks.

 

 

Gas supply connection plug 

ISO7-1 R1/2 connection plug 

Non-metal gasket with thickness of 2 mm 

Pipe adapter for liquid gas (depending on the model) 

 

Only use pipes and seals in accordance with the Standards

. These pipes must be 

installed so that, when fully extended, their length does not exceed 2000 mm. For easier 
installation and to prevent gas leaks, attach the swivel coupling to the cook top first, and then 
to the gas mains pipe. Inverting this sequence may hamper the gas seal between the pipe 
and the cook top.  

Important: when the installation is complete, check that all couplings are completely 
sealed by using a soapy solution. Never use a flame. Also ensure that the flexible pipe 
cannot come into contact with any moving part of the cook top (e.g. drawer) and that it 
is not in a position where it could be damaged.  

 

After the connection, check the burners for correct operation. 
The flames must be clearly visible, and should be blue and green at the center. If the flame is 
unstable, increase the minimum power.  

 

Adaptation to a 
different type of gas

 

• The procedure or adaptation of the cooker to another type of gas does not require removal 
of the appliance from the worktop. 
• Before adapting, disconnect the appliance from the power mains and close the gas supply 
valve. 
• Replace the existing nozzles for nominal thermal load with corresponding nozzles for the 
new gas type and supplied provided (see table below). 
• After finishing this sequence, replace the old setting label with the new one provided for the 
new injectors. 
 

Adjustment elements

 

 

To leave the adjustment elements accessible, please observe the following instructions: 
• Remove the support grid and burner covers with respective crowns. 
• In double burners, adjustment elements are accessible behind the main nozzle protective 
plate. 
• Remove the control knobs. Be carefull when removing knobs with time control function 
(both left knobs). Inside these knobs is interconnection cable, do not try to remove the cable. 

Gas valve 

Minimum thermal load regulation valve 

 

Minimum flow 
adjustment  

Instructions for town (G110, G120, G150.1) and methane gas (G20, G25) 

1. Light the burner and bring it to the minimum position. 
2. Remove the gas tap knob and turn the adjustment screw on the side of the tap rod: 

x

 

anti-clockwise to increase the gas flow 

x

 

clockwise to reduce the gas flow  

until a regular minimum flame is obtained. 
3. Re-assemble the knob and verify burner flame stability (when quickly rotating the hand 
from maximum to minimum position the flame must not shut off). 
4. Repeat the operation on all gas taps. 

 

Instructions for liquid gas (LPG: G30, G31) 

Tighten the screw on the side of the tap, rod clockwise completely. 

 
 

Warning: these tasks may only be carried out by a qualified technician, authorized by the gas distributing 
company or authorized service center! 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 499602

Page 1: ...1...

Page 2: ...2...

Page 3: ...functions that your particular appliance may not have These instructions are only valid of the country symbol is indicated on the appliance If there is NO county symbol in the appliance technical inst...

Page 4: ...he cooking surfaces WARNING If the surface is cracked switch off the appliance to avoid the possibility of electric shock Do not use high pressure steam cleaner or hot steam to clean the appliance Nev...

Page 5: ...no less than 150mm Use of massive wood decoration plates or boards on the worktops behind the cooking hob is permitted if the minimum distance remains the same as indicated in the installation drawin...

Page 6: ...lower side of the hob The appliance is manufactured for use with the power supply voltage 220 240 V In order to make a fixed connection to the mains insert an all pole circuit breaker between the app...

Page 7: ...ncluded in Table ADAPTATION TO A DIFFERENT TYPE OF GAS The version of this appliance is indicated on the rating plate This appliance is not suitable for connection to a burning fumes exhaust system i...

Page 8: ...alve Replace the existing nozzles for nominal thermal load with corresponding nozzles for the new gas type and supplied provided see table below After finishing this sequence replace the old setting l...

Page 9: ...YPE OF GAS pg84 ENERGY EFFICIENCY 499602 499604 499606 TYPE OF HOB BUILT IN N BURNERS 4 4 5 EEGAS HOB 60 3 62 4 61 7 BURNER EEBURNER A SR 61 9 R 63 4 MW 57 3 TC 59 7 Important warnings The gas burners...

Page 10: ...before using the appliance Stainless steel working table can burnish when subjected to excessive heat Therefore we don t recommend prolonged cooking with soapstone earthenware pans or cast iron plates...

Page 11: ...level Any setting between 0 and the large flame is not recommended as the flame is not stable in this interval and may be extinguished WARNING once the cook top has been cleaned ensure that the burner...

Page 12: ...ning dry all surfaces with a clean cloth Make sure that the flame slits are clean and completely dry The surface of the burner crown cover will become more matt with time This is quite normal and will...

Page 13: ...ctions should also be included Following is some advice on rectifying some common problems PIJKLMN PJOOQKLM RSUOM FLQNQVSWQJV The flame is uneven unstable Wrong gas power setting Have an expert check...

Page 14: ...ci nienia HU Cikksz m C lorsz gban Kateg ri k Gas s a nyom st HR Art br Zemlja odredi ta Kategorija Plinom i pritisci SK Artiklu Krajiny ur enia Kateg rie Plynu a tlaky SL Art No Namembna dr ava Kate...

Reviews: