9
Conversion to another
type of gas
(only with some models)
x
The appliance should not be removed from the worktop.
x
Before converting, disconnect the appliance from the power mains and close the gas
supply valve.
x
Remove the support grid and burner covers with respective crowns.
x
Replace the existing nozzles for nominal thermal load with corresponding nozzles for
the new gas type and supplied provided (see Nozzle table). In double burners,
adjustment elements are accessible behind the main nozzle protective plate.
x
After finishing this sequence, replace the old setting label with the new one provided for
the new injectors.
x
The category with the related types of gas can be used are included in
ފ
Conversion to a
different type of gas
ފ
table.
Minimum flow adjustment
Instructions for town (G110, G120, G150.1) and methane gas (G20, G25)
1. Light the burner and bring it to the minimum position.
2. Remove the control knobs, including the gaskets.
3. Turn the adjustment screw on the side of the tap rod until a regular minimum flame is
obtained:
x
anti-clockwise to increase the gas flow;
x
clockwise to reduce the gas flow.
4. Re-assemble the knob and verify burner flame stability (when quickly rotating the hand
from maximum to minimum position the flame must not shut off).
5. Repeat the operation on all gas taps.
Instructions for liquid gas (LPG: G30, G31)
Tighten the screw on the side of the tap, rod clockwise completely.
TECHNICAL INFORMATIONS
426150
429254
429253
439193
426152
426160
426167
439192
426164 - 426162
426166 - 450420
426153 - 567006
426149
A
: Auxiliary
SR
: Semirapid
R
: Rapid
MW
: Mini-Wok
TC
: Triple Crown
Operating voltage
220-240 V~ ; 50/60 Hz
Regulated for gas
G20=20mbar
G30=30mbar
G30=30mbar
G30=30mbar
G20=20mbar
Qn
TOT
7500 W
7800 W
11300 W
11300 W
7500 W
426147
426158 - 453969
453969 - 429255
439422
439421
439427
439425
A
: Auxiliary
SR
: Semirapid
R
: Rapid
MW
: Mini-Wok
TC
: Triple Crown
Operating voltage
220-240 V~ ; 50/60 Hz
Regulated for gas
G30=30mbar
G20=20mbar
G20=13mbar
G20=13mbar
G20=13mbar
Qn
TOT
7500 W
11300 W
7500 W
7800 W
7500 W
426159
663459 - 663463
A
: Auxiliary
SR
: Semirapid
R
: Rapid
MW
: Mini-Wok
TC
: Triple Crown
Operating voltage
220-240 V~ ; 50/60 Hz
Regulated for gas
G20=20mbar
G30=50mbar
Qn
TOT
11300 W
11300 W