5.3 Setting the parameters of SECU-A5.4L On PV Master app
5.4 Observing the indicator status.
LED Indication
SOC Indicator
Operation
Indicator
Green, Blink 1s
Green, Blink 10s
Green, Blink 3s
Red, Blink 3s
Standby
Normal
Warning
Error
Operation Indicator
SOC < 5%
5%≤ SOC ≤25%
25%≤ SOC ≤50%
50%≤ SOC ≤75%
75%≤ SOC ≤95%
95%≤ SOC ≤100%
Operation Indicator
Operation LED
Green Blink
3 seconds
SOC LED
Warning Description
Cell Temperature Difference
Battery High Temperature
Discharge Under Low Temperature
Charge Overcurrent
Discharge Overcurrent
Battery Over Voltage
Battery Under Voltage
Charge Under Low Temperature
Operation LED
Red
Blink
3 seconds
SOC LED
To make sure the battery communicates to inverter unit successfully, users have to use PV
Master to choose the right battery option on PV Master:
APP Installation And Connection:
Connect phone & Inverter
Wi-Fi SSID: Solar-WiFi***
Password: 12345678
Download
and install
PV Master
Note: If Battery Under Voltage happens during working status, by pressing battery switch for 5
times in 10 seconds, BMS will compulsively close MOS, so that inverter will detect battery open
circuit voltage to charge battery.
Select “SECU-A5.4L” on battery page in PV
Master Application
Notes:
1. Select wrong battery will lead to BMS
communication failure
2. Select wrong number of batteries the
input and output current will be limited
and the parameter indicated by the
converter is inconsistent with the actual
value of the battery.
3. For the complete commissioning of the
whole ESA system, please go to ESA
instruction.
Select Battery on PV master
6. Error Code and Warning Code
Warning Status
Select Battery Model
GoodWe
BYD
GCL
LG
PYLON
DYNESS
AlpahESS
eSTORE
Temperature Sensor
Failure
MOS Fault
Breaker Open
NO SN
Firmware Inconsistency
Multi Master Unit
MOS Over temperature
Error Description
Solution
Reboot battery or contact aftersales
Reconnect communicatioin cable
Contact aftersales
Reconnect communication cable
Contact aftersales
Turn off battery for 2 hours
DIP Switch Status
difference
Turn Off battery and contact
aftersales
Keep same of DIP switch status and
reboot battery
Turn off and reboot all batteries in
30s
Slave Communication
Loss
Master Communication
Loss
play
App Store
Error Status
SECU-A5.4L*1
SECU-A5.4L*2
SECU-A5.4L*3
SECU-A5.4L*4
SECU-A5.4L*5
SECU-A5.4L*6
08
07