![Goodwe Lynx Home LX U5.4-L User Manual Download Page 15](http://html1.mh-extra.com/html/goodwe/lynx-home-lx-u5-4-l/lynx-home-lx-u5-4-l_user-manual_2244292015.webp)
12
Power Cable Connection
1. Crimp the power cable.
2. Put the rubber seal ring.
3. Secure the back shell.
• Connect the red power cable to the red wire harness, and the black power
cable to the black wire harness. The cross-sectional area of the crimping part is
25mm².
• Withstand Voltage: DC1500V; Temperature: -40℃~200℃.
• Stripped conductor length: 18±1mm.
• Secure the back shell and check whether there is any gap.
• Recommended tool: manual hydraulic press plier(mould:25mm²)
• Drawing force after crimping≥1200N.
• If a single battery is applied, you are suggested to connect any one of the two
power ports and cover the other port using the protective cover.
• Connect power cables between multi batteries in parallel, which means
connect postive pole of one battery to the positive pole of the next battery,
and negative pole to negative pole. Cover and protect the reserved power
port of the last battery.
• The power cable between the batteries should be as short as it can be and meet
installation requirements.
Length:7.5±0.2mm
Height:7.5±0.2mm
4. Connect the power cable.
1
2
3
Click