47
User Manual V1.0-2022-10-30
11 Appendix
Max. Output Fault
Current (Peak and
Duration) (A/ms)
25@5ms
25@5ms
25@5ms
25@5ms
Inrush Current (Peak
and Duration) (A/us)
50@2us
50@2us
50@2us
50@2us
Nominal Output Current
(A)
3.0
4.3
6.5
8.7
Power Factor
~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic
Distortion
<3%
Maximum Output
Overcurrent Protection
(A)
22.3
22.3
22.3
22.3
Efficiency
Max. Efficiency
97.2%
97.2%
97.3%
97.5%
European Efficiency
96.0%
96.4%
96.6%
97.0%
Protection
PV Insulation Resistance
Detection
Integrated
Residual Current
Monitoring
Integrated
Anti-islanding Protection
Integrated
AC Overcurrent
Protection
Integrated
AC Short Circuit
Protection
Integrated
AC Overvoltage
Protection
Integrated
DC Switch
Integrated
DC Surge Protection
Type III (Type II Optional)
AC Surge Protection
Type III
AFCI
Optional
Emergency Power Off
Optional
Remote Shutdown
Optional
Remote Shutdown
Optional
General Data
Operating Temperature
Range (℃)
-25~+60
Relative Humidity
0~100%
Max. Operating Altitude
(m)
3000