3.4.2 DC Side Connection

Cable specification of AC side is showed as Figure 3.4.1-2.

(

1

)

damage the unit.

(

2

)

The open circuit voltage of the PV strings cannot exceed the maximum input voltage of the inverter.

(

3

)

Only DC connectors provided by us are permitted to use.

 

(

4

)

The positive and negative pole is forbid to connect PE wire (Ground wire), otherwise, it will damage the unit.

(

5

)

Don't connect positive or negative pole of PV string to PE wire. Otherwise, it will cause damage to inverter.

Before connecting the PV strings, please ensure the plug connectors have the correct polarity. Incorrect polarity could permanently 

05

06

A

B

3.4 Electrical Connection

3.4.1 Connection to grid (AC side Connection)

(

1) Check the grid voltage and frequency if it can comply with the required voltage and frequency of inverter connection.

(

2) It

 

is suggested that the breaker or fuse will be added in the AC side, its current should be over 1.25 times of rated current.

(

3)

 

Measure the impedance of neutral wire and ground wire to make sure it’s less than 10 ohm.

(

4)

 

Disconnect the breaker or fuse between the inverter and the utility.

(

5

Connect the inverter to the grid as follows:

Put the

 

AC cable through the components in this order: screw cap, one-hole sealing ring, insulation body and sheet metal parts.

 

The

 

way

 

of

 

connecting

 

the

 

AC

 

cable

 

can

 

be

 

shown

 

as

 

Figure

 

3

.

4

.

1

-

1

.     

E

C

Figure

 

3.4.1-1

Screwdriver

T

he

 

Insulator

AC

 

output

 

board

AC

 

wire

M3X8

 

screw

AC

 

connector

Single

 

hole

 

seal

 

ring

Screw

 

cap

Grade

   

Description

  

A

       

O

.

D

.

  

B

       

  

C

       

Bare Wire Length

Conductor Material
Sectional Area

Value

4~5mm

2

2.5~4mm

7mm around

3.4.3 USB Communication

USB cable should be connected as Figure 3.4.3-1.

Figure 3.4.3-1

If you need USB monitoring solution, please download EzExplorer software at www.goodwe.com.cn.

Installation instruction of the DC connector

 

refer to Figure 3.4.2-1.

Figure

 

3.4.2-1

DC Cable specification is showed as Figure 3.4.2-3.

Figure

 

3.4.2-3

A

B

C

7mm

7mm

2

2

.

5

~

4mm

2

2

.

5

~

4mm

PV

connector

(

Standard

 

Accessories

)

PV

connector

(

Standard

 

Accessories

)

inverter

 

side

1

.

open

 

the

 

UBS

 

cover

2

.

insert

 

the

 

US

 

data

 

cable

B

Make

 

sure

 

the

 

cable

 

is

 

connected

 

well

 

and

 

can

'

t

 

be

 

plugged

 

out

 

after

 

connecting

 

with

 

AC

 

terminals

.

For GW2500-NS and GW3000-NS, if use 

 please connect the Branch Socket to the DC connector of the inverter first, 

refer to Figure 3.4.2-2.

Branch Socket,

Figure 3.4.2-2

Summary of Contents for GW1000-NS

Page 1: ...NS SERIES USER MANUAL 350 00092 03 SOLAR INVERTER Official Website Company Wechat...

Page 2: ...s 7 Certificates 3 1 Mounting Instructions 3 2 Inverter Overview and Package 3 3 Inverter Installation 3 4 Electrical Connection 4 1 Indicator Lights 4 2 User Interface and Use of the Display 4 3 Erro...

Page 3: ...lectro magnetic equipment should be kept away from installation site Product label and warning symbol shall be clear to read after installation Please install inverter in the place where is not expose...

Page 4: ...s Refer to Figure 3 3 1 1 Upward 300mm Downward 500mm Front 300mm Both sides 200mm Figure 3 3 1 1 3 3 Inverter Installation MAX 15 3 3 2 Mounting Procedure 1 Use the wall mounted bracket as a template...

Page 5: ...to make sure it s less than 10 ohm 4 Disconnect the breaker or fuse between the inverter and the utility 5 Connect the inverter to the grid as follows Put the AC cable through the components in this...

Page 6: ...S checking time is based on safety and varies from country to country indicates the inverter is self checking counting down and preparing for power generation Normal indicates the inverter is generat...

Page 7: ...is something wrong with the system an error message is shown Please refer to chapter 5 View PV voltage PV current grid voltage current and frequency Short press the key to enter the E Today menu whic...

Page 8: ...onfigure the Wi Fi again as 3 4 5 after using the function Press the key until the LCD displays Wi Fi Reset then long press 2S until the LCD displays Wi Fi Resetting Stop pressing and wait for the scr...

Page 9: ...1500 NS DC input Data Max DC power W Max DC voltage V MPPT voltage range V Starting voltage V Max DC current A DC overcurrent protection A No of DC connectors No of MPPTs DC overvoltage category DC co...

Page 10: ...occurs The pollution has no influence Pollution degree 2 Normally only non conductive pollution occurs Occasionally however a temporary conductivity caused by condensation must be expected Pollution...

Reviews: