1

01

Safety and Warning

•  The documentation may be updated from time to time due to product upgrades or other 

reasons. Unless otherwise specified, information in the documentation do not replace safety 

cautions in the labels. All descriptions in the documentation are used for guidance only.

•  Please read the user manual carefully to acquire knowledge about product features and 

safety precautions before installing the equipment. GoodWe will not be liable for any 

equipment damages or personnel injuries caused by failure to install, operate or configure 

the inverter in accordance with this document or corresponding user manual.

•  Please follow local laws and regulations, and safety cautions in this manual during the 

installation, operation, and maintenance. Improper operation or misuse may result in 

personal injuries or property losses.

•  All installation, operation, and maintenance must be carried out by trained professionals 

who meet the following requirements:

•  read through this manual

•  be familiar with various safety precautions

•  operate properly

•  acquaint with local laws, regulations, and standards.

•   To ensure safety, please use insulated tools and wear personal protective equipment when 

operating the equipment.

•  Always comply with electrostatic protection rules. To protect the inverter from being 

damaged, please wear anti-static gloves, wrist strap and clothes when touching printed 

circuit board or other electrostatic sensitive components during operation. 

•  Power off the equipment before any cable connection or electrical operation.

•  Residual high voltage exists after the equipment is powered off. To avoid electric shock, please 

wait for 5minutes for the equipment to discharge to safe voltage.

•  Do not plug or pull DC/AC terminals when the equipment is running.

•  PV negative (PV-) and battery negative (BAT-) on inverter side is not grounded by default. 

Connecting PV- or BAT- to EARTH is strictly forbidden.

General safety cautions

Operation Safety Precautions

•  Destroying the labels without authorization will void the guarantee of corresponding modules.

•  Do not install the inverter when it is snowing or raining. If you have to, pay attention to the 

waterproof and moisture-proof of the inverter and distribution box.

•  Avoid drilling holes in walls which with cables inside or on the back.

•  The polarity of PV strings or on the inverter cannot be connected by reversely, otherwise 

inverter could be damaged.

•  PV cable must be tightly crimped in to the connectors.

Summary of Contents for EHB Series

Page 1: ...EHB Series Quick Installation Guide Ver 1 0 2020 12 30...

Page 2: ...e insulated tools and wear personal protective equipment when operating the equipment Always comply with electrostatic protection rules To protect the inverter from being damaged please wear anti stat...

Page 3: ...ic shock or chemical hazard Please following Cments and steps bellow strictly Use improper wire may cause bad contact and high impedance which is dangerous to the system The equipment damage caused by...

Page 4: ...the Inverter Packing List Smart Meter 1 CT 1 Wall Mounted Bracket 1 Wall Mounted Bracket 1 6 Pin Terminal 2 Positive PV Plug 1 Negative PV Plug 2 Positive BAT Plug 1 Negative BAT Plug 1 WiFi module 1...

Page 5: ...4 140 mm 106 mm 120 182 mm 120 110 192 mm 415 mm 791 mm 150 mm 395 mm 175 mm Dimension Angle Space 15 200mm 300mm 500mm 200mm 300mm...

Page 6: ...ation locating plate 2 Install the wall mounted bracket 3 Install the inverter 4 Secure the inverter with a lock 5 Ensure that the switch is on OFF position and locked during installation and maintena...

Page 7: ...ery AC Breaker AC Breaker Model PV Cable BAT Cable AC Cable PE Cable GW5000 EHB 3 4mm 12 13mm 5 6mm 5 6mm GW6500 EHB 3 4mm 12 13mm 8 10mm 8 10mm GW8600 EHB 3 4mm 12 13mm 10 12mm 10 12mm GW0010 EHB 3 4...

Page 8: ...3 1 Use the right plugs in the accessory box Prepare cables and plugs 2 Connect cables to connectors 3 Screw the cap on and plug onto inverter side 1 Use the right plugs in the accessory box Prepare...

Page 9: ...ver and screw up the terminal cap 4 Connect the assambled AC terminals onto inverter 13 22mm 10 15mm 12 14mm 1 2 Make sure terminal cover is locked up here 3 4 AC breaker AC breaker Load breaker Load...

Page 10: ...down Connection NO DRED port definition Reserved port definition RS485 port definition 1 DRM1 5 CANL2 RS485_B2 2 2 DRM2 6 CANH2 RS485_A2 2 3 DRM3 7 GND S LG_EN 3 4 DRM4 8 12V S LG_EN 3 5 REFGEN Remote...

Page 11: ...nnect the data monitoring device The RS485 port shall be connected in the same way as the DRED port If the DRED and Remote Shutdown functions are not used make sure that the Resistance is inserted int...

Page 12: ...P PV Master app is an external monitoring configuration application for the hybrid inverters Please download PV Master app from GoodWe o cial website www goodwe com Connect to the WiFi Bluetooth port...

Page 13: ...tting Long press REST button longer than 3s WiFi LED on inverter will blink until doing WiFi configuration again WiFi Reset Reload function is only used when 1 WiFi lost connection to internet or cann...

Page 14: ...on algorithm Pleas e ent er t he wireles s net work pas s word Password 8 63 bytes show psk Back Next WiFi Test WPA WPA2 PSK AES hellogoodwe Not e case sensitive for SSID and password Please make sure...

Page 15: ...ON Grid is active and connected BLINK Grid is active but not connected OFF Grid is not active ON Consuming energy from grid buying BLINK 1 Supplying energy to grid zeroing BLINK 2 Supplying energy to...

Page 16: ...SUPPLY TECHNOLOGY CO LTD No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com PV Master APP SEMS Portal APP SEMS Portal website www semsportal com LinkedIn Company s o cal...

Reviews: