background image

CC-400HF HI-FLO 0121

4

16.

   The unit is equipped with an automatic by-pass valve that recirculates water inside 

the pump when the spray gun trigger is released. Although the unit has a thermal 

discharge valve for protection, avoid leaving the unit running in by-pass mode for 

more than five (5) minutes.

17.

  

IMPORTANT:

 Do not carry the unit by the pump guard as it is not designed to be 

used as a handle!!!

18.

  

DO NOT ADJUST BYPASS PRESSURE:

 The bypass pressure is factory set – 

adjustments may damage unit!

Electrical Precautions

1.

   Make certain that the power source conforms to the requirements of  

the equipment.

2.

   Keep all connections dry and off the ground. Do not handle the unit or electrical 

plug with wet hands.

3.

   Unplug the power cord when servicing the unit or leaving the machine unattended.

4.

   Do not pull on the power cord or pull the cord around sharp corners. Keep the cord 

away from hot surfaces. When unplugging the power cord, grasp the plug – not  

the cord.

5

  

WARNING:

 The cords, wires, and/or cables supplied with this product may contain 

chemicals, including lead or lead compounds, known to the State of California to 

cause cancer and birth defects or other reproductive harm. Always wash hands 

thoroughly after handling the unit.

6.

  

GROUNDING INSTRUCTIONS:

 For proper protection this product must be 

grounded. Always plug the power cord into a properly grounded receptacle. Never 

remove the grounding prong from the power cord plug or use an adapter that 

eliminates ground.

7.

  

GROUND FAULT CIRCUIT INTERRUPTER:

 This unit is provided with a Ground 

Fault Circuit Interrupter built into the power cord plug to prevent electrocution. DO 

NOT RUN THE UNIT WITHOUT THIS DEVICE!! If replacement of the plug or cord 

becomes necessary, use only identical replacement parts that include  

GFCI protection.

8.

  

EXTENSION CORDS:

 Use only extension cords that are intended for outdoor 

use. These extension cords are identified by a marking “Acceptable for use with 

outdoor appliances; store indoors while not in use.” Use only extension cords having 

an electrical rating not less than the rating of the product. Do not use damaged 

extension cords. Examine extension cord before using and replace if damaged. Do 

not abuse extension cord and do not yank on any cord to disconnect. Keep cord 

away from heat and sharp edges. Always disconnect the extension cord from the 

receptacle before disconnecting the product from the extension cord.

SAVE THESE INSTRUCTIONS

Summary of Contents for Hi-Flo CC-400HF

Page 1: ...CC 400HF Hi Flo COIL CLEANER Operating and Maintenance Instructions Read before operating...

Page 2: ...eciate your business and look forward to serving you in the future As with all Goodway products you can be assured that the finest quality components and workmanship have gone into this machine Please...

Page 3: ...ng this unit 7 Do not use while tired or under the influence of drugs alcohol or medication 8 Do not overreach or stand on unstable support Keep proper footing and balance at all times 9 Wear rubber g...

Page 4: ...to cause cancer and birth defects or other reproductive harm Always wash hands thoroughly after handling the unit 6 GROUNDING INSTRUCTIONS For proper protection this product must be grounded Always p...

Page 5: ...to remove loose debris 4 Remove Yellow Rinsing Nozzle from Spray Gun Lance 5 Attach Soap Nozzle Stainless Steel size 1520 6 Make sure chemical pickup hose is in chemical container and the tip is at t...

Page 6: ...WWSS HF Replacement Water Seal Kit for Pump RCC 10 SK 90 Brass Tip WWSS 60 90DEG Motor Power Requirements 1HPAC Motor 1 115VAC 15 0Amps Water Requirements 3 0 GPM 11 4LPM Maximum Inlet Water Pressure...

Page 7: ...03 2509 RCC 15 1 808 842 RCC 02 G RCC 04 684 2X 9008 2X RCC 12 RCC 19 RCC 16 2 HWN 252 2X 802 RCC 07 1 BSL 45EL50FX50M 9527 RCC 10 HWN 37L 4X RCC 16 935 2 ft RCC 18 2X X2 05 03 2X 2509 HWN 252 2X HWS...

Page 8: ...HWS 2520 125P Screw 1 4 20 Panhead 1 25 8 HWW 252 Washer 1 4 4 RCC 01 G Mounting Plate Molded Front 1 RCC 02 G Mounting Plate Molded Rear 1 RCC 03 G Cover Tube 1 RCC 04 Baffle Rear 1 RCC 06 1 Tube 3 4...

Page 9: ...CC 400HF HI FLO 0121 9 ON OFF Switch DO NOT LAY UNIT DOWN ON THIS END DO NOT LIFT OR CARRY BY PUMP GUARD Lift by handle only Hoist point Hoist point Thermal Relief Valve Chemical Hose...

Page 10: ...CC 400HF HI FLO 0121 1 0 NOTES...

Page 11: ...CC 400HF HI FLO 0121 1 1 NOTES...

Page 12: ...tamford CT USA Effective date January 12 2021 Goodway is a Trademark of Crossford International Goodway reserves the right to improve products contact the factory for the latest configuration and uses...

Reviews: