GVC-72000
7
Function of the P1 and P2 Buttons:
The buttons are used to read out the total hours run by the machine. To read out do
as follows:
1.
Press P2 (5.6) to visualize the hours run up to 999 – the display shows 3 digits.
2.
Press P1 (5.8) to visualize the hours up to 99000 – the display shows 2 digits.
Now sum up both, for example if you press P2 and read 317 and then press P1 and
read 04 then you have a total of 4317 hours which the machine has run.
Hand-grip (Pic.4)
3.1
3.2
3.1
Trigger
3.2
Hot Water Injection On/Off
3.3
Steam Lance Nozzle
SET – UP
1.
Remove from packaging and inspect unit. Report any discrepancies to
Goodway Technologies Corporation’s Customer Service at (800) 370-2855.
2.
Attach handle to the front of the unit using four included fasteners.
3.
Position this vapor-steam cleaner in the area it will be used.
4.
Connect the unit to the plant’s wiring. See nameplate for power requirements.
It is imperative that the ground connection is properly made. See grounding
instructions for more information.
5.
Connect water supply hose to connector on rear of unit. Water supply pressure
must be between 1.5 psi and 100 psi.
6.
Insert the Steam Hose into Connection Socket (1, 2, or 9) on front of machine,
especially when using the 72kW steam gun (note - pull back slightly on ring of
hose connector to allow insertion into socket for the 72kW gun).
7.
Connect output end of hose to accessory or nozzle for cleaning application.