GVC-1502-VAC 0920
7
Description
GVC-1502-VAC
Stainless steel boiler capacity
(continuous filling)
0.6 gallon (2,3 liters)
Water tank capacity
1.3 gallons (5 liters)
Heating time
5 minutes
Pressure in use (kinetic energy)
90 psi (6 bar)
Maximum temperature
320°F (160°C)
Maximum power
1500 W
Power requirement
115V 50/60 Hz
Steam production
8 lbs/hour
(3,6 kg/hour)
SPECIFICATION
OPERATING INSTRUCTIONS
1.
Lift the protective cover and plug the steam hose into the steam hose
connecting socket. When the plug is located correctly it will click into place.
2.
Unscrew the filler cap and carefully fill the tank with water.
DO NOT ADD ANY KIND OF CLEANING CHEMICAL TO THE WATER TANK.
3.
Plug unit into appropriate supply.
4.
Turn main switch ON to start the machine. The ON/OFF indicator light
will illuminate.
5.
The green light flashing indicate that boiler is being filled with water. Wait until
the pump stops filling the boiler (ready light goes on.).
6.
Switch ON the boiler at the ON/OFF switch. After approximately 5 minutes
from cold fill, the machine reaches 90 ± 5 psi (6 bar) steam pressure and a
temperature of 320°F (160°C) inside the boiler.
7.
The green indicator light will illuminate when the machine is ready.
8.
Choose the accessory that you wish to use. Connect it to the pistol grip by
clicking into place. Before you start cleaning, direct the nozzle into a suitable
receptacle and depress the trigger on the handle to blow out residual
condensation from the steam hose.
9.
Now direct the steam jet onto the surface you wish to clean and depress
the trigger.
Summary of Contents for GVC-1502-VAC
Page 11: ...GVC 1502 VAC 0920 11 NOTES...