    Consult the Goodway catalog for heavy-duty water supply hose. Turn on 

water supply. 

DO NOT RUN PUMP DRY.

  2.  Plug the electric cord into a grounded outlet of proper voltage for the  

machine. Make sure the outlet is fused for a minimum Amps listed on the 

units nameplate. Any additional extension cord must be grounded and be 

a minimum of 10-3 gauge wire. Goodway offers a 20 Amp, 10-3 gauge, 50' 

(15.2m) cord – see catalog.

  3.  Fill built-in chemical container with soap solution or other chemical.

  4.  Turn unit on, green light will illuminate (watertight switch and light are 

located on side of power unit). Pull trigger on spray gun to activate unit.

CHEMICAL OR SOAP INJECTION: ALL MODELS

  

It is recommended that liquid chemical or soap be used whenever possible as 

powders may not be completely dissolved and may clog the siphon injector.   

The chemical dip tube is supplied with a strainer to minimize contamination  

of the siphon injector.

The dip tube may be placed in the tank supplied or in a drum of solution if  

prolonged application of solution is required. The dip tube may have to be  

lengthened when using 30 or 55 gallon (114 or 208 liter) drums of solution.

CHEMICAL OR SOAP INJECTION: GPW-1200

  1.  Fill plastic container with chemical or soap.

  2.  Connect plastic dip tube and turn machine on. A dip tube strainer is  

provided and should be attached to dip tube.

  3.  The GPW-1200 is supplied with the standard adjustable spray nozzle [P/N 5812  

(High-Lo Nozzle)]. The nozzle will draw chemical or soap at low pressure  

(approx. 150 PSI/10BAR). The following describes their features and operation.

 

Adjustable High-Low Pressure Nozzle (P/N 5812)  

 

 

Pressure  is regulated by turning collar on spray nozzle.  

 

Turn the collar fully counterclockwise (as viewed from  

 

spray handle) for maximum pressure. One full turn clockwise  

 

will decrease pressure to 150 PSI (10 BAR) at which point  

 

chemical or soap will be injected in the spray. 

 

 

 

Summary of Contents for GPW-1000

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS 1 00 PRESSURE WASHERS GPW 1200 GPW 1000 GPW 1000 P GPW 2003 GPW 2502...

Page 2: ...A Copyright 2004 Goodway Technologies Corporation Stamford CT U S A Goodway is a Trademark of Per K Reichborn Goodway reserves the right to improve products Contact the factory for the latest con gur...

Page 3: ...local water utility to see if a back ow preventer is required WARNING Risk of Injection or Severe Injury Keep Clear of Nozzle Do Not Direct Discharge Stream at Humans or Animal This Product Is to be...

Page 4: ...ating of the product Do not use damaged extension cords Examine extension cord before using and replace if damaged Do not abuse extension cord and do not yank on any cord disconnect Keep cord away fro...

Page 5: ...a maximum of 160 F 71 C to improve cleaning action See MAINTENANCE for further information regarding warm water operation 4 Since the high pressure spray is very powerful DO NOT AIM AT OR SPRAY HUMANS...

Page 6: ...004 Tighten securely 3 Place chemical container if used on top of unit inside the retaining bail and place dip tube inside container Make sure dip tube strainer is attached to dip tube 4 Connect the h...

Page 7: ...of proper voltage for the machine Make sure the outlet is fused for a minimum of 15 Amps Any additional extension cord must be grounded and be a minimum of 12 3 gauge wire Goodway offers a 20 Amp 10 3...

Page 8: ...AVOID DAMAGING THE FITTINGS NOTE Either control hose can be connected to either valve OPERATION 1 Connect water hose capable of delivering a minimum of 2 5 GPM 13 LPM to inlet and turn on faucet Cons...

Page 9: ...e is supplied with a strainer to minimize contamination of the siphon injector The dip tube may be placed in the tank supplied or in a drum of solution if prolonged application of solution is required...

Page 10: ...0 P The GPW 1000 and GPW 1000 P utilize quick disconnect nozzles To initiate chemical soap injection install the nozzle with the large ori ce This nozzle delivers low pressure 200 PSI 13 8 BAR and aut...

Page 11: ...ds to a ratio of 100 1 of the undiluted chemical For mix ratio of 1 tablespoon per gallon of water prepare a premix solution of 1 part chemical to 10 parts of water For mix ratio of 1 teaspoon per gal...

Page 12: ...ong Let cool down Motor Electric Models run without spraying protector will reset automatically and motor can be started Extension cord too long or Change extension cord inadequate size Fuse blown Plu...

Page 13: ...n or plugged relief Clean reset and valve on pump replace worn parts Cavitation Check suction lines on inlet of pump for restrictions Water in crankcase High humidity Reduce oil change interval Noisy...

Page 14: ...the cover as marked Use simple push type grease gun lled with Moly Lithium No 2 grease wheel bearing grease MAINTENANCE GPW 2003 GPW 2502 CRANKCASE LUBRICATION The GPW 2003 and GPW 2502 are shipped wi...

Page 15: ...plumbing assembly out of housing DISASSEMBLY GPW 2003 GPW 2502 Access to the internal parts is gained by removing the front cover allowing for pump lubrication and component repair replacement REPAIR...

Page 16: ...14 GPW 1200...

Page 17: ...15 GPW 1000...

Page 18: ...16 GPW 1000 P...

Page 19: ...17 GPW 2003 GPW 2502...

Page 20: ...9 9625 E Mail goodway goodway com Internet www goodway com Goodway Technologies Corporation manufactures and distributes a complete line of Tube Pipe Cleaning Systems Duct Cleaning Systems Vacuums Ste...

Reviews: