ELECTRICAL ADJUSTMENTS
1.
2.
3.
4.
5.
Receive the monoscope pattern.
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (1) on the remote control.
The Fig. 2-6 appears on the display.
Press the channel button (1) on the remote control to
select "H. PHASE".
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on right and
left becomes minimum.
2-11: HORIZONTAL PHASE
1.
2.
3.
4.
5.
2-15: OSD HORIZONTAL
Receive monoscope pattern.
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (5) on the remote control.
The Fig. 2-2 appears on the display.
Press the channel button (4) on the remote control to
select "OSD H".
Press the VOL. UP/DOWN button on the remote control
until the difference of A and B becomes minimum.
(Refer to Fig. 2-7)
Fig. 2-6
1. H. PHASE
2. H. BLK
3. V. SIZE
4. V. POSI
5. V. LIN
6. V. SC
7. V. COMP
8. (H FREQ) 0. RETURN
2-12: VERTICAL SIZE
1.
2.
3.
4.
5.
Receive the monoscope pattern.
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (1) on the remote control.
The Fig. 2-6 appears on the display.
Press the channel button (3) on the remote control to
select "V. SIZE".
Press the VOL. UP/DOWN button on the remote control
until the horizontal over scan is equal to the vertical over
scan.
2-13: VERTICAL LINEARITY
1.
2.
3.
4.
5.
Receive the monoscope pattern.
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (1) on the remote control.
The Fig. 2-6 appears on the display.
Press the channel button (5) on the remote control to
select "V. LIN".
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on upside
and downside becomes minimum.
2-14: VERTICAL POSITION
1.
2.
3.
4.
5.
Receive the monoscope pattern.
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (1) on the remote control.
The Fig. 2-6 appears on the display.
Press the channel button (4) on the remote control to
select "V. POSI".
Press the VOL. UP/DOWN button on the remote control
until the horizontal line of the monoscope comes to
approximate center of the CRT.
[ TV ]
OSD H
A
B
Fig. 2-7
2-16: VERTICAL LINEARITY 60 (AV)
1.
2.
3.
4.
5.
Receive the monoscope pattern (Audio Video Input).
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (1) on the remote control.
The Fig. 2-6 appears on the display.
Press the channel button (5) on the remote control to
select "V. LIN".
Press the VOL. UP/DOWN button on the remote control
until the horizontal line of the colour bar comes to
approximate center of the CRT.
D2-3