background image

Page 4.4

4

Air  Conditionin

g

  &  Heatin

g

6 Conductor 18 gauge 
unshielded cable from the 
thermostat to the equipment.

Residential Heat Pump with O Reversing 
Valve 1 Stage Cooling, with 2 stage Heat 

6 Wire, 1 Stage Cooling, 2 Stage Heat

HP

GAS

B

O

ELEC

GAS

(F

A

N

)

24 vac return 

fan relay

compressor relay

Reversing Valve

O

W

2

 

G

R

C

Y

1

24 vac common

2nd stage heat circuit 

4

Y1

G

R
C

W1/O/B

RS+5

RSGND

W2

OUT

HP

GAS

B

O

ELEC

GAS

(F

A

N

)

H

U

M

N

O

 H

U

M

W1

Y1

G

R

C

W2

OUT

RSGND

RS+5

CTRL

Summary of Contents for TSTATG2111

Page 1: ...ng up to 2 Heat 1 Cool up to 2 Heat 1 Cool CONFIGURABLE IN SETUP Auto or Manual changeover Programmable or Non Programmable Aux Heat Indicator Outdoor Sensor Ready with High Low Readouts for the Day A...

Page 2: ...ce must accept any interference received including interference that may cause undesired operation Follow the Installation Instructions before proceeding Set the thermostat mode to OFF prior to changi...

Page 3: ...4 5 Preparation Remove Replace the Old Thermostat Sample Wiring Diagrams Calibrating the Thermostat Sensors Test Operation TroubleShooting Page iii Table of Contents Wire Connections Air Conditioning...

Page 4: ...ng Air Conditioning system at the main fuse panel Most residential systems have a separate breaker for disconnecting power to the furnace Proper installation of the thermostat will be accomplished by...

Page 5: ...eep the old thermostat for reference purposes until your new thermostat is functioning properly Disconnect the wires from the old thermostat Tape the ends of the wires as you disconnect them and mark...

Page 6: ...structions on connecting these terminals see page 4 6 Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked G or F Fan G Y1 Y or C Cooling Y1 W1 W or H H...

Page 7: ...Page 4 1 Section 4 Contents HVAC Equipment Wiring 4 2 Installing the Outdoor Sensor 4 6 SECTION 4 Sample Wiring Diagrams 4 Air Conditioning Heating...

Page 8: ...return fan relay compressor relay 1st stage heat circuit W1 W2 G R C Y1 5 Wire 1 Stage Cooling 1 Stage Heat 24 vac common 2nd stage heat circuit HP GAS B O ELEC GAS FAN Residential Commercial 1 Stage...

Page 9: ...tial Commercial 1 Stage Cooling with 1st stage Electric Heat 5 Wire 1 Stage Cooling 1 Stage Electric Heat HP GAS B O ELEC GAS FAN 24 vac return fan relay compressor relay 1st stage heat circuit W1 G R...

Page 10: ...with O Reversing Valve 1 Stage Cooling with 2 stage Heat 6 Wire 1 Stage Cooling 2 Stage Heat HP GAS B O ELEC GAS FAN 24 vac return fan relay compressor relay Reversing Valve O W2 G R C Y1 24 vac comm...

Page 11: ...Pump with b Reversing Valve 1 Stage Cooling with 2 stage Heat 6 Wire 1 Stage Cooling 2 Stage Heat HP GAS B O ELEC GAS FAN 24 vac return fan relay compressor relay Reversing Valve b W2 G R C Y1 24 vac...

Page 12: ...This is an unshielded cable with four twisted pairs of 24 gauge solid wire DO NOT use stranded cable The cable length should not exceed 250 feet If less than 75 feet of cable is required to connect t...

Page 13: ...re The air conditioner should turn on Press the UP Turn the power on to the Heating Air Conditioning system Press the UP button until the setpoint is equal to the room temperature Press the FAN button...

Page 14: ...rocedure MODE Place the thermostat in the OFF mode MODE Press button While holding the MODE button press and hold the FAN button for 5 seconds All icons will appear on the display and hold the MODE CA...

Page 15: ...d on to the furnace and that you have 24vac between R W and 24vac between R C SYMPTOM The air conditioning does not attempt to turn on CAUSE The cooling setpoint is set too high REMEDY Consult the Own...

Page 16: ...set for b REMEDY Set the reversing valve jumper for O See pages 4 4 and 4 5 SYMPTOM When calling for cooling both the heat and cool come on CAUSE The thermostat equipment jumper is configured for HP a...