Goodman SSZ16 Product Specifications Download Page 1

P

roduct

 S

PecificationS

SS-SSZ16

www.goodmanmfg.com

1/10

Supersedes 8/09

SSZ16

to

 5 t

onS

UP

 

TO

 16 SEER

The  Goodman

®

  brand  SSZ16  Heat  Pump  uses  the 

chlorine-free  refrigerant  R-410A.  In  addition,  the 
SSZ16  features  energy  effi

  ciencies  and  operating 

sound levels that are among the best in the heating 
and cooling industry.

c

ooling

 c

aPacitY

24,000 

to

 57,000 Btu/

H

H

eating

 c

aPacitY

24,000 

to

 57,000 Btu/

H

Standard Features

•  R-410A chlorine-free refrigerant
•  High-effi

  ciency Copeland® scroll compressor

Single-Stage — 2 through 4 tons; Two-Stage — 5 tons

•  High- and low-pressure switches
•  High-quality compressor sound blanket
•  850 RPM condenser fan motor
•  Liquid refrigerant return protection
•  Factory-installed, bi-fl ow liquid line fi lter dryer
•  Service valves with sweat connections and 

gauge ports

•  Copper tube/enhanced aluminum fi n coil
•  Reliable time-initiated, temperature-terminated 

defrost control

•  Contactor with lug connection
•  Ground lug connection
•  AHRI Certifi ed; ETL Listed

Cabinet Features

•  Goodman brand sound control top design
•  Steel louver coil guard
•  Heavy-gauge galvanized-steel cabinet 
•  Attractive Architectural Gray powder-paint fi nish 

with 500-hour salt-spray approval

•  Top and side compressor and tubing access
•  Service ports and controls are accessible while 

unit is operating

•  When properly anchored, meets the 2001 Florida Build-

ing Code unit integrity requirements for hurricane-type 
winds. (Anchor bracket kits available.)

Contents

Nomenclature ................................................................................... 2
Product Specifi cations ................................................................... 3
Expanded Cooling Data ................................................................ 4
Expanded Heating Data .............................................................. 12
AHRI Performance Ratings ......................................................... 13
Wiring Diagrams ............................................................................ 16
Dimensions ...................................................................................... 20
Accessories ...................................................................................... 20

H

igH

-e

fficiencY

 r-410a

S

Plit

 S

YStem

 H

eat

 P

umP

        

        

*  To receive the Lifetime Compressor Limited Warranty and 10-Year Parts Limited Warranty, online regis-
tration must be completed within 60 days of installation. Online registration is not required in California 
or Québec. Full warranty details available at www.goodmanmfg.com.

Summary of Contents for SSZ16

Page 1: ...terminated defrost control Contactor with lug connection Ground lug connection AHRI Certified ETL Listed Cabinet Features Goodman brand sound control top design Steel louver coil guard Heavy gauge ga...

Page 2: ...R 410A Nominal Capacity Efficiency 018 1 Tons 048 4 Tons 13 13 SEER 024 2 Tons 060 5 Tons 14 14 SEER 030 2 Tons 090 7 tons 16 16 SEER 036 3 Tons 120 10 Tons 042 3 Tons Neither used for order entry or...

Page 3: ...inimum Circuit Ampacity 17 9 18 7 25 9 33 Max Overcurrent Protection 30 30 40 50 Min Max Volts 197 253 197 253 197 253 197 253 Electrical Conduit Size or or or or Ship Weight lbs 282 282 282 296 Teste...

Page 4: ...0 62 0 40 0 94 0 85 0 64 0 41 0 98 0 87 0 66 0 42 1 00 0 91 0 69 0 44 1 00 0 91 0 69 0 44 T 20 18 15 10 20 19 15 10 20 19 15 10 20 19 15 11 20 18 15 10 18 17 14 10 kW 1 45 1 48 1 53 1 58 1 56 1 59 1...

Page 5: ...429 448 Lo PR 109 116 127 135 115 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 145 159 169 85 984 MBh 24 8 25 2 26 4 28 2 24 2 24 7 25 8 27 6 23 6 24 1 25 2 26 9 23 0 23 5 24 6 26 2...

Page 6: ...0 39 0 92 0 82 0 62 0 40 0 95 0 85 0 64 0 41 0 98 0 88 0 67 0 43 0 99 0 89 0 67 0 43 T 20 19 15 11 21 19 15 11 21 19 15 11 21 19 16 11 20 19 15 11 19 18 14 10 kW 2 00 2 04 2 11 2 18 2 16 2 20 2 28 2...

Page 7: ...R 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 158 133 141 154 164 85 1350 MBh 35 71 36 40 38 12 40 67 34 88 35 55 37 23 39 72 34 04 34 70 36 35 38 78 33 21 33 86 35 46...

Page 8: ...40 0 93 0 83 0 63 0 41 0 96 0 86 0 65 0 42 1 00 0 89 0 68 0 44 1 00 0 90 0 68 0 44 T 22 20 17 11 22 20 17 12 22 20 17 12 22 21 17 12 22 20 17 11 20 19 16 11 kW 2 70 2 76 2 84 2 93 2 90 2 97 3 06 3 16...

Page 9: ...428 447 Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 156 167 85 1744 MBh 49 0 50 0 52 3 55 8 47 9 48 8 51 1 54 5 46 7 47 6 49 9 53 2 45 6 46 5 48 7 51...

Page 10: ...38 0 90 0 80 0 61 0 39 0 92 0 83 0 63 0 40 0 96 0 86 0 65 0 42 0 97 0 87 0 65 0 42 T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 12 22 20 16 11 20 19 15 11 kW 3 60 3 68 3 80 3 93 3 89 3 97 4 10 4 24...

Page 11: ...430 449 Lo PR 99 105 115 122 104 111 121 129 109 115 126 134 114 121 132 141 119 127 139 148 124 131 144 153 85 2025 MBh 58 8 60 0 62 8 67 0 57 5 58 6 61 3 65 4 56 1 57 2 59 9 63 9 54 7 55 8 58 4 62...

Page 12: ...0 1 Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 5 10 MBh 59 1 55 9 52 6 49 2 47 0 45 5 42 3 39 0 35 4 32 6 30 1 28 4 27 3 24 5 21 7 19 0 16 2 13 3 T 35 3 33 4 31 4 29 4 2...

Page 13: ...0 16 13 22 200 18 400 23 000 9 5 15 000 3598988 CA F3636 6C TXV A VC950704CXA 24 000 18 700 16 13 22 200 18 400 23 000 9 5 15 000 3598998 CA F3636 6C TXV G VC90704CXA 23 400 18 300 16 13 21 600 17 900...

Page 14: ...743 6A TXV G VC951155DXA 34 600 26 300 16 13 32 000 25 900 34 400 9 5 21 000 3599483 CA F3743 6A TXV A VC80704CXA 34 000 25 800 15 12 5 31 500 25 500 34 600 9 5 21 000 3629731 CA F3743 6A TXV A VC8090...

Page 15: ...90905DXA 36 000 27 400 16 13 33 300 27 000 34 600 9 5 23 000 3599085 CT F4860 6A TXV G VC950704CXA 36 000 27 400 15 5 12 5 33 300 27 000 34 600 9 5 23 000 3599313 CT F4860 6A TXV G VC950905DXA 34 600...

Page 16: ...34 000 3599421 CT F4860 6A TXV G VC951155DXA 46 000 35 400 16 13 42 600 34 900 46 000 9 5 34 000 3599573 SSZ16 0601A AEPF426016C TXV 57 000 42 200 15 11 5 52 700 41 600 57 000 9 34 600 1492641 CA F496...

Page 17: ...SA START ASSIST SC START CAPACITOR FOR COMPRESSOR OPTIONAL S R START RELAY FOR COMPRESSOR OPTIONAL CONTROLS SHOWN WITH THERMOSTAT IN OFF POSITION T1 L1 T2 L2 ALTERNATE DOUBLE POLE CONTACTOR OUTDOOR PO...

Page 18: ...AL S R START RELAY FOR COMPRESSOR OPTIONAL CONTROLS SHOWN WITH THERMOSTAT IN OFF POSITION OUTDOOR POWER SUPPLY SEE RATING PLATE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAG...

Page 19: ...IN OFF POSITION OUTDOOR POWER SUPPLY SEE RATING PLATE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE RD SA IF USED NOTE 2 LVJB CONTROL...

Page 20: ...e Protection Kit X X X X OT18 60A Outdoor Thermostat w Lockout Stat X X X X TX2N4 TXV Kit X TX3N4 TXV Kit X TX5N4 TXV Kit X X Contains 20 brackets four brackets needed to anchor unit to pad Installed...

Reviews: