background image

Scuka Enterprises Ltd
881 Highway 33 E
Kelowna, BC , V1X 6V1

Submittal

Submittal 27.2: PKHS # 27.2 Cooling Units DS-1

APPROVERS (ASSIGNEES):

CREATED BY:

Brett Sichello (Philip Mac Donald Architect Inc.)

Lisa Duckworth

PROJECT:

ISSUE DATE:

Penticton Kiwanis
150 Van Horne Street
Penticton, BC, V2A 4K2
Canada

07/16/10

PROJECT NUMBER:

SUBMITTAL NO / REVISION:

SC-415

27.2 / 0

COST CODE:

STATUS:

Closed

SUBMITTAL TYPE:

BALL IN COURT:

Shop Drawing

SPEC SECTION:

RECEIVED FROM:

RECEIVED DATE:

Lisa Duckworth (Scuka Enterprises Ltd)

07/16/10

COPIES TO:

REQUESTED REPLY DATE:

Ben Duckworth
Lisa Duckworth
Joe Dees

07/21/10

DESCRIPTION:

7/20 email from supplier:

DS-1

Originally specified TKU09VM which we do not carry and crossed over to 9CQ Fujitsu.

Hello!

Attached are the PKHS shop drawings for the cooling units DS-1 (office) for you and the consultant to review.

If you require any further information, please do not hesitate to contact me at 250-765-0136 or 250-859-5891.

Thank you! Lisa

REFERENCES / ATTACHMENTS

415 2010-07-16 SD 27.2 Room AC Wall Mounted.pdf

APPROVER RESPONSES

APPROVER NAME

DATE SENT

DATE
RETURNED

STATUS

ATTACHMENTS

COMMENTS

Brett Sichello

07/16/10

08/13/10

Approved As
Noted

415 2010-08-11 SD 27 2
Room AC Wall Mounted
DS-1.pdf

2010-08-13

Summary of Contents for PACKAGE TERMINAL AIR CONDITIONER/HEAT PUMP

Page 1: ...IES TO REQUESTED REPLY DATE Ben Duckworth Lisa Duckworth Joe Dees 07 21 10 DESCRIPTION 7 20 email from supplier DS 1 Originally specified TKU09VM which we do not carry and crossed over to 9CQ Fujitsu...

Page 2: ...Email from Brett on Aug 12 BY DATE COPIES TO...

Page 3: ...ion Remember it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use Safety is a matter ofcommon sense a matter of thinking...

Page 4: ...ct between existing practices and the content of this manual the precautions listed here take precedence A RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION AWARNING GOODMAN WILL NOT BE RESPONSIBLE FOR ANY...

Page 5: ...tus The LEOs next to the selections OFF COOL and HEATindicate which operational mode is active The LED located in the lower left corner is a status LED This LED indicates the status of the unit See Di...

Page 6: ...he event of damage the consignee must 1 Make notation on delivery receipt of any visible damage to shipment or container 2 Notify carrier promptly and request an inspection 3 In case of concealed dama...

Page 7: ...he rear closure panel pull the entire panel out diagonally from one side DRAIN KIT INSTALLATION OPTIONAL ACCESSORy During normal reverse cycle heating operation condensate water will drain out of the...

Page 8: ...ive to determine if the new chassis should be used with the non standard specialized grille An improper outdoor grille can decrease cooling or heating capacity increase energy usage and shorten compre...

Page 9: ...SHOCK DO NOT USE AN EXTENSION CORD WITH THIS UNIT A CAUTION To AVOID THE RISK OF PROPERTY DAMAGE PERSONAL INJURY OR FIRE USE ONLY COPPER CONDUCTORS A CAUTION To AVOID THE RISK OF PROPERTY DAMAGE PERS...

Page 10: ...e available if a fan speed is selected without COOL or Heat selection Fan Operation HIGH or LOW with HEAT or COOL mode selected The selected fan speed shall run in the selected speed Fan Operation AUT...

Page 11: ...for wired unrented setback energy management see Configuration Settings section c2 EH and IN terminals are used instead of FD1 and FD2 If EH and IN are shorted the unit will go into setback temperatur...

Page 12: ...o operate this unit with a manufacturer approved remote thermostat configure the control to be operated by the remote thermostat Enter configuration mode C1 and then select option Code L5 see Configur...

Page 13: ...Heat F Jrrp Thermostat Input Electric Heat Thermostat Input RTermnal to RTermnal to OFF NONE NONE HEATI Stage 1 I Stage 2 GL Y1W1 B O GL W2 GL YIW1 B or GL W2 0 nfa OOOL GL Y1W1 B 0 GL YIW1 or GH dep...

Page 14: ...inlet air filters be cleaned once per month or more often if operated in dusty or dirty locations or conditions The intake air filters are con structed of durable polypropylene The air intake air filt...

Page 15: ...he wall sleeve while cleaning the unit The caulking around the sleeve should be checked to make sure that any potential air and water openings around the sleeve are properly sealed The wall sleeve s l...

Page 16: ...er is applied in this mode In the AUTO position the fan will cycle on and off with the compressor or electric heater Starting delay You may notice a few minutes delay in the starting if you try to res...

Page 17: ...ired Occupancy O Off 1 On 18 18 Hour Automatic Entry C8 Temp Limiting Cool 60 n 60 n C9 Temp Limiting Heat 68 90 80 68 90 80 Cd English I Metric Temp F Fahrenheit Scale C Celsius Scale d6 Sensorless U...

Page 18: ...iagnostic Status Report mode press and hold the up and down arrows and while holding quickly press the COOL key twice ACTIVE FAILURES If there are no active failures or lockouts the display will show...

Page 19: ...N N Replace Wireless Thermostat F3 IndoorAmbient Thermistor reeds Y N Replace black Indoor Ambient Thermistor outsile the range 20 F to 200 F F4 Indoor Col Thermistor either above N Y Replace Red Ind...

Page 20: ...THIS PAGE INTENTIONALLY LEFT BLANK 18...

Page 21: ...THIS PAGE INTENTIONALLY LEFT BLANK 19...

Page 22: ...registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company loP Houston TX AU rights reserved 5151 San Felipe Suite 500 Houston TX77056 www amana...

Page 23: ...YearWarranry Pans Labor Second through Filth Year Parts Labor on certai e led system components Second througn Fifth veaL on cerlain unctior 1 pans only t Complete warranrydetai s availabte at l lV W...

Page 24: ...ertain sealed system components 2nd through 5th year on certain functional parts only For complete warranty details visit www amana ptac com 100 Run Tested All units are 100 run tested at our plant in...

Page 25: ...eless remote thermostat is set up both the remote thermostat and unit control panel continue to control the unit providing flexibility and home like system control Installation requires no more than p...

Page 26: ...and Thermostat connect at the press of a button and are permanently linked The thermostat and PTAC work in sync to display accurate temperature The DigiSmartWireless Antenna installs inside the PTAC w...

Page 27: ...es System Verification A lBft _lMl l_tmr Global Setbacks EMS Configuration Site Statistics Battery Notices Email Reporting Unit Health Unit Code Alerts Temp Limiting Each PTAC can be configured with a...

Page 28: ...ELEnRI HEAT 230 208 VOLTS 265 277 VOLTS Approximately 95 CFM with optional power vent kit Actual vent CFM performance will vary due to application and installation conditions See Notes on following pa...

Page 29: ...09 B A 7 Specify two digit heater kW size to complete model number S Total amps for 12 000 and 15 000 BTU h models subtract 0 2 amps for PT0710gosoA 9 R 410A refrigerant used in all systems 10 All uni...

Page 30: ...EAT PUMP ELEnRI HEAT 230208 VOLTS 265 277 VOLTS Approximately 95 CFM with optional power vent kit Actual vent CFM performance will vary due to application and installation conditions See Notes on prev...

Page 31: ...le NEMA 6fDnfi uralion I I 30amp 15 amp 20 amp 2mRating Power ord Plugs HEMA7 onfiguralion 20 amp 30amp Power Re eptacle Configuration NEMA6 15R 250V receptacie used en 230120BV units NEMAS 20R 250V r...

Page 32: ...units controlled Via awi ed remote thermostat Covers control touch pad for wired thermostat insrallations SUBBASE KIT The fully skirred subbase conceals wiring while proViding strong support If needed...

Page 33: ...O IA allows fOI the new S series I mit to work with the A series duct kits MDK02B I Main Duct R 22 MDK02E I M inDuct R 410A EDK02B IExtension Duct TDK02 PTDKOIA PTDKOIE POWER VENT Krr In lallation of...

Page 34: ...ss with a kit installed Unit must be connected to and operated bya wall thermostat Hydronic Heat Kit Rl9ht View HWK038 HydronicWater Kit R 22 HVK038 Hydronic Steam Kit R 22 HWK03E Hydronk Water Kit R...

Page 35: ...ed into the cabinet front using the cabinet filter guides Before cleaning the intake filters turn the unit off by setting the mode switch to the OFF position Filters should be cleaned as requiredThe f...

Page 36: ...t MAX y Ifo 40 3 4 CQ CENTRJC l5 n CKOUTS SACK J ilL BenOM Of SUBBASE ELECTRICAL oHLy j I RIGHT 0 ID 18 CORD SET 285V UNIT RlfiHI YIEW AIR DI CHARGE GRILLE IS RSlBlE TO PROlilDE EITHER 718 15 OR W Dl...

Page 37: ...n from a finished wall See Note 4 if using hydronic units 2 Drain Kit DK900D shipped separately Can be mounted either right side left side or bottom of sleeve If mounted to bottom of sleeve allow 2 he...

Page 38: ...th Year Parts labor on certaiii sealed system component S Second through Fifth Year on certai 1 funcrior al parts only Complete warranty derails 3V Jllabie at www amana orac com Amana is a trademark o...

Page 39: ...RFI INFORMATION COST CODE REFERENCE LOCATION DRAWING NUMBER M 03 SPECIFICATION SECTION RFI DESCRIPTION QUESTION 1 Fully describe the question or type of information requested Posted by Joe Dees Hi All...

Page 40: ...ng machine drain Regards Brett Sichello B Arch Sci LEEDR AP 326 Uplands Drive Kelowna B C V1W 4J7 T 250 764 4157 F 250 764 4857 E brett pma architect ca _____ Attachments image001 jpg Response From Cu...

Reviews: