Main Menu Buttons -
Settings
The right column of the ADR configuration page is where the
occupant adjusts the operational parameters for ADR. The utility
may send up to 3 types of ADR signals to Skyport. These are:
1) Pricing for the cost of energy, 2) An Offset to the occupants’
comfort setpoints, and 3) a signal to enforce discrete or Static
setpoints.
The Maximum Cooling Setpoint and Minimum Heating Setpoints
for ADR events are adjusted here.
The Static Settings are applied when the utility sends a signal
to allow the occupant to enforce their own discrete temperature
settings during an ADR event.
The Offset Settings allow the utility to modify the Cool or Heat
setpoints by the value set here during an ADR event.
A Price Trigger setting allows the occupant to set the maximum
cost of energy threshold. When this threshold is exceeded
the Price dependent action is enforced. This Price Trigger and
Dependent action is enforced independent of an ADR event, as
long as the utility sends ‘real-time’ pricing.
Summary of Contents for GT4273
Page 1: ...Owner s Manual Installation Guide RESIDENTIAL model GT4273...
Page 19: ...11 Main Menu Buttons Schedule Schedule View My Schedule Edit My Schedule...
Page 54: ...46 Main Menu Buttons Settings The user may limit the maximum Cooling Setpoint...
Page 55: ...47 Main Menu Buttons Settings The user may limit the minimum Heating Setpoint...
Page 56: ...48 Main Menu Buttons Settings The user may adjust the ADR Cooling static Setpoint...
Page 57: ...49 Main Menu Buttons Settings The user may adjust the ADR Heating static Setpoint...
Page 95: ...Printed on recycled paper P N 88 1143 Rev 2 11 15 Patents Issued Pending...