28
www.goodmanmfg.com
SS-GSZ14
SS-GSZ14
www.goodmanmfg.com
29
Expanded Heating Data
GSZ140181K* - ARUF25B14** + TXV
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
MBh
23.71
22.11
20.54
18.99
18.00
17.25
15.37
13.65
12.25
11.21
10.42
10.00
9.47
8.13
6.80
5.47
4.13
T/R
36.0
33.6
31.2
28.8
27.3
26.2
23.3
20.7
18.6
17.0
15.8
15.2
14.4
12.3
10.3
8.3
6.3
kW
1.51
1.48
1.45
1.42
1.40
1.39
1.36
1.33
1.30
1.27
1.24
1.22
1.21
1.18
1.15
1.12
1.09
Amps
7.2
6.6
6.1
5.7
5.5
5.3
5.0
4.7
4.4
4.2
4.0
3.8
3.8
3.5
3.3
3.0
2.7
COP
4.60
4.37
4.15
3.92
3.76
3.63
3.31
3.01
2.76
2.59
2.46
2.40
2.29
2.02
1.74
1.43
1.11
GSZ140191A* - ARUTXV
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
MBh
23.71
22.11
20.54
18.99
18.00
17.25
15.37
13.65
12.25
11.21
10.42
10.00
9.47
8.13
6.80
5.47
4.13
T/R
35.99
33.56
31.17
28.82
27.32
26.18
23.33
20.72
18.60
17.01
15.82
15.18
14.37
12.35
10.32
8.30
6.27
kW
1.63
1.57
1.50
1.44
1.40
1.37
1.30
1.24
1.17
1.11
1.04
1.00
0.98
0.91
0.85
0.78
0.71
Amps
7.1
6.6
6.1
5.7
5.4
5.3
5.0
4.7
4.4
4.2
4.0
3.8
3.7
3.5
3.3
3.0
2.7
COP
4.26
4.13
4.01
3.88
3.78
3.69
3.45
3.23
3.06
2.96
2.93
2.92
2.84
2.62
2.36
2.05
1.70
GSZ140241K* / ARUFTXV
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
MBh
30.74
28.63
26.55
24.50
23.20
22.20
19.70
17.43
15.59
14.20
13.16
12.60
11.89
10.13
8.36
6.59
4.83
T/R
32.7
30.5
28.3
26.1
24.7
23.6
21.0
18.6
16.6
15.1
14.0
13.4
12.7
10.8
8.9
7.0
5.1
kW
1.97
1.93
1.88
1.84
1.81
1.79
1.75
1.70
1.66
1.61
1.57
1.54
1.52
1.48
1.43
1.39
1.34
Amps
9.1
8.4
7.8
7.2
6.9
6.7
6.3
5.9
5.6
5.3
5.0
4.8
4.7
4.4
4.1
3.7
3.3
COP
4.57
4.36
4.14
3.91
3.76
3.63
3.31
3.00
2.76
2.58
2.46
2.40
2.29
2.01
1.71
1.39
1.05
GSZ140251A* - ARUTXV
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
MBh
29.87
28.00
26.17
24.36
23.20
22.36
20.21
18.21
16.57
15.36
14.48
14.00
13.39
11.85
10.32
8.79
7.25
T/R
32.16
30.15
28.17
26.23
24.98
24.07
21.76
19.60
17.84
16.54
15.58
15.07
14.41
12.76
11.11
9.46
7.81
kW
1.85
1.82
1.79
1.75
1.74
1.72
1.69
1.66
1.63
1.59
1.56
1.54
1.53
1.50
1.46
1.43
1.40
Amps
8.7
8.0
7.4
6.9
6.6
6.4
6.0
5.6
5.3
5.0
4.7
4.6
4.5
4.2
3.9
3.5
3.2
COP
4.73
4.51
4.29
4.07
3.92
3.80
3.50
3.22
2.99
2.83
2.72
2.66
2.57
2.32
2.07
1.80
1.52
Calculations are based on nominal CFM and 70°F indoor dry bulb.
Amps = Outdoor unit amps (comp.+fan)
Note: Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature.
kW = Total system power