4
www.goodmanmfg.com
SS-GSX14
SS-GSX14
www.goodmanmfg.com
5
Product Specifications (cont.)
GSX14
0361K*
GSX14
0371K*
GSX14
0421K*
GSX14
0431K*
GSX14
0481K*
GSX14
0601K*
Capacities
Nom Cool (BTU/h)
36,000
36,000
42,000
42,000
48,000
60,000
SEER/EER
14 / 12
14 / 12.2
14 / 12
14 / 12.2
14 / 11.7
14 / 11.7
Decibels
73
73
73
73
74
75
Compressor
RLA
14.1
14.1
16.7
16.7
19.9
25.0
LRA
77
72.2
79
79
109
134
Condenser Fan Motor
Hp
1/6
1/6
1/6
1/6
1/4
1/4
FLA
0.95
0.95
0.95
0.95
1.3
1.3
Refrigeration System
Refrigerant Line Size ¹
Liquid Line Size (“O.D.)
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
Suction Line Size (“O.D.)
⅞"
⅞"
1⅛"
1⅛"
1⅛"
1⅛"
Refrigerant Connection Size
Liquid Valve Size (“O.D.)
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
Suction Valve Size (“O.D.) ² ³
¾"
¾"
⅞"
⅞"
⅞"
⅞"
Valve Type
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Charge
81
81
93
93
101
120
Included piston:
0.068
0.071
0.074
0.074
0.078
0.088
Electrical Data
Voltage-Phase (60 Hz)
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
208/230-1
Minimum Circuit Ampacity ⁴
18.6
18.6
21.8
21.8
26.2
32.6
Max. Overcurrent Protection ⁵
30 amps
30 amps
35 amps
35 amps
45 amps
50 amps
Min/Max Volts
197/253
197/253
197/253
197/253
197/253
197/253
Conduit
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
Equipment Weight
162
162
189
189
220
260
Shipping Weight
180
180
207
207
242
280
¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with AHRI Standard 210/240.
For other line-set lengths or sizes, refer to the installation & Operating instructions and/or the long line-set guidelines.
² Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
⁴ Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
⁵ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
•
Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.