CONDENSING UNIT SPECIFICATIONS
6
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
GSX130[18-60]1A*
GSX130181A*
GSX130241A*
GSX130301A*
GSX130361A*
Cooling Capacity, BTUH
18,000
24,000
30,000
36,000
Compressor
R.L. Amps
9.00
13.4
12.8
16.6
L.R. Amps
48.0
58.3
64.0
79.0
High Pressure Switch
Open
610 PSIG
610 PSIG
610 PSIG
610 PSIG
Close
420 PSIG
420 PSIG
420 PSIG
420 PSIG
Condenser Fan Motor
Horsepower
1/6
1/6
1/6
1/6
F.L. Amps
1.10
1.10
1.10
1.10
Liquid Line, Inches O.D.*
3/8"
3/8"
3/8"
3/8"
Suction Line, Inches O.D.*
3/4"
3/4"
3/4"
3/4"
Refrigerant Charge
120.0
116.0
129.0
131.0
Power Supply
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
Minimum Circuit Ampacity
(1)
12.3
17.9
17.1
21.9
Maximum Overcurr ent Device
(2)
20
30
30
35
Electrical Conduit Size
Power Supply (Inches)
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
Approxim ate Shipping Weight
178
178
180
197
GSX130421A*
GSX130481A*
GSX130601A*
Cooling Capacity, BTUH
42,000
48,000
60,000
Compressor
R.L. Amps
17.9
19.8
26.4
L.R. Amps
112.0
109.0
134.0
High Pressure Switch
Open
610 PSIG
610 PSIG
610 PSIG
Close
420 PSIG
420 PSIG
420 PSIG
Condenser Fan Motor
Horsepower
1/6
1/4
1/4
F.L. Amps
1.10
1.50
1.50
Liquid Line, Inches O.D.*
3/8"
3/8"
3/8"
Suction Line, Inches O.D.*
7/8"
7/8"
7/8"
Refrigerant Charge
151.0
166.0
184.0
Power Supply
208/230-60-1
208/230-60-1
208/230-60-1
Minimum Circuit Ampacity
(1)
23.5
26.3
34.5
Maximum Overcurr ent Device
(2)
40
45
60
Electrical Conduit Size
Power Supply (Inches)
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
Approxim ate Shipping Weight
219
225
240
(1)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device:
MUST
use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
* Line sizes denoted for less than 25' line sets, tested and rated in accordance with AHRI Standard 210/240. For other line-set lengths or sizes, refer to
the Installation and Operating Instructions and/or the long line-set guidelines.