SS-GPH14H
www.goodmanmfg.com
3
s
Pecifications
GPH14
24H41A*
GPH14
30H41A*
GPH14
36H41A*
GPH14
42H41A*
GPH14
48H41A*
GPH14
60H41A*
C
oolinG
C
APACity
AHRI Cooling Capacity (BTU/h)
24,000
28,400
36,000
40,500
46,000
57,000
Sensible BTU/h
18,200
23,400
27,400
29,600
35,400
40,500
SEER / EER
14.5 / 12.0
14.0 / 12.0
14.0 / 11.5
14.0 / 12.0
14.0 / 12.0
14.0 / 12
Decibels
76
76
78
78
80
80
AHRI Numbers
4385132
4385133
4385134
4385135
4385136
4385137
H
eAtinG
C
APACity
BTU/h (47°F)
22,800
27,600
32,200
37,600
44,000
54,500
C.O.P. (47°F)
3.8
3.8
3.7
3.8
3.8
3.6
BTU/h (17°F)
13,000
15,400
20,400
21,600
26,000
33,800
C.O.P. (17°F)
2.4
2.5
2.4
2.4
2.4
2.5
HSPF
8.0
8.0
8.0
8.0
8.0
8.0
e
vAPorAtor
M
otor
Type
EEM
EEM
EEM
EEM
EEM
EEM
Wheel (D x W)
10 x 8
10 x 8
10 x 8
10 x 8
10 x 8
11 x 8
Cooling CFM
875
1,050
1,200
1,300
1,600
1,700
Fan-Only CFM
800
950
1,100
1,200
1,400
1,600
RLA
1.5
1.86
1.86
2.9
2.9
2.9
No. of Speeds
5
5
5
5
5
5
Horsepower - RPM
½ - 1,050
½ - 1,050
½ - 1,050
½ - 1,050
¾ - 1,050
¾ - 1,050
e
vAPorAtor
C
oil
Face Area (ft
2
)
5.25
4.67
5.2
6.2
6.2
7.0
Rows Deep/ Fins per Inch
3/ 16
4/ 16
3/ 14
4/ 14
4/ 14
4/ 14
Indoor Metering Device Size
0.057
0.065
0.068
0.072
0.076
0.088
Filter Size (ft
2
)
20 x 20 x 1
20 x 25 x 1
25 x 25 x 1
(2) 20 x 20 x 1
(2) 20 x 20 x 1
(2) 20 x 25 x 1
Drain Size (NPT)
¾"
¾"
¾"
¾"
¾"
¾"
Refrigerant Charge (oz.)
85
105
125
150
190
200
C
ondenser
F
An
/ C
oil
Horsepower - RPM
1/6 - 815
1/6 - 815
¼ - 1075
¼ - 1075
¼ - 1075
¼ - 1075
RLA/LRA
1.1 / 1.7
1.1 / 1.7
1.5 /3.0
1.4 / 2.9
1.4 / 2.9
1.4 / 2.9
Fan Diameter / # Fan Blades
22 / 3
22 / 3
22 / 4
22 / 4
22 / 4
22 / 4
Face Area (ft
2
)
13.4
13.4
17
17
19.1
19.1
Outdoor Metering Device Size
0.049
0.047
0.067
0.065
0.065
0.071
Rows Deep/ Fins per Inch
1 / 24
1 / 24
1 / 24
1 / 24
2 / 16
2 / 16
C
oMPressor
Quantity
1
1
1
1
1
1
Type
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Stage
Single
Single
Single
Single
Single
Single
e
leCtriCAl
d
AtA
Voltage/Phase/ Frequency
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
Compressor RLA/LRA
12.8 / 58.3
14.1 / 73
16.7 / 79
17.9 / 112
19.9 / 109
26.4 / 134
Indoor Blower FLA
1.5
1.86
1.86
2.9
2.9
2.9
Outdoor Fan RLA
1.1
1.1
1.4
1.4
1.4
1.4
Total Unit Amps
15.4
17.06
19.96
22.2
24.2
30.7
Min. Circuit Ampacity¹
18.6
20.6
24.2
26.6
29.2
40.2
Min. Overcurrent Protection (amps)²
30
30
40
40
45
60
s
HiP
W
eiGHt
(
lbs
)
325
325
385
385
415
415
o
PerAtinG
W
eiGHt
(
lbs
)
315
315
375
375
405
405
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Note:
Always check the S&R plate for electrical data on the unit being installed.