5

COMPONENT IDENTIFICATION

Upflow/Horizontal

1

Gas Valve

2

Gas Line Entrance (Alternate)

3

Pressure Switch

4

Gas Manifold

5

Combustion Air Intake Connection / “Coupling”

6

Hot Surface Igniter

7

Rollout Limit

8

Burners

9

Flame Sensor

10

Flue Pipe Connection / “Coupling”

11

Flue Pipe (Internal)

12

Primary Limit

13

Gas Line Entrance

14

Flue Pipe Connection (Alternate)

15

Rubber Elbow

16

Induced Draft Blower

17

Electrical Connection Inlets (Alternate)

18

Coil Front Cover Pressure Tap

19

Coil Front Cover Drain Port

20

Drain Line Penetrations

21

Drain Trap

22

Blower Door Interlock Switch

23

Integrated Control Module

(with fuse and diagnostic LED)

24

24-Volt Thermostat Connections

25

Transformer (40 VA)

26

Circulator Blower

27

Auxiliary Limit

28

Junction Box

29

Electrical Connection Inlets

30

Coil Front Cover

Summary of Contents for GME95

Page 1: ...alog for part number information Model numbers listed on page 3 Copyright 2011 2013 Goodman Manufacturing Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL...

Page 2: ...e responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you assume responsibility for any personal injury or...

Page 3: ...lations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise contact your local EPA office WARNING WARNING Do...

Page 4: ...ountered This light can be viewed through the observation window in the blower access door Refer to the Troubleshooting Chart for further explanation of the LED codes and Abnormal Operation Integrated...

Page 5: ...t 13 Gas Line Entrance 14 Flue Pipe Connection Alternate 15 Rubber Elbow 16 Induced Draft Blower 17 Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Po...

Page 6: ...GAS SUPPLY HOLE DRAIN TRAP 19 3 4 AIR INTAKE PIPE 2 PVC LEFT SIDE DRAIN LINE HOLES 1 5 8 RIGHT SIDE VIEW CONDENSATE DRAIN TRAP w 3 4 PVC DISCHARGE RIGHT OR LEFT SIDE 2 C B FRONT VIEW A DISCHARGE 1 1...

Page 7: ...A N A N A GME951005DXA 1 50 1 35 0 25 0 10 0 10 20197308 1 35 0130F00110 N A N A N A NEGATIVE PRESSURE COIL COVER WITH FLUE FIRING TYPICAL SEA LEVE DATA 2 NEGATIVE PRESSURE COIL COVER WITH FLUE NOT F...

Page 8: ...XA 1 GME951005DXA 1 AUXILIARY LIMIT SWITCHES Part Number 10123533 10123517 Open Setting F 200 210 GME950403BXA 1 GME950603BXA 2 GME950805CXA 2 GME951005DXA 2 ROLLOUT LIMIT SWITCHES Part Number 0130M00...

Page 9: ...C D heights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C...

Page 10: ...g airflow requirement Permanent Minimum Filter Area in2 Based on 600 ft min filter face velocity Minimum filter area dictated by heating airflow requirement Cabinet Width in Nominal Filter Size in App...

Page 11: ...ter length and number of elbows NOTE This data is provided as a guide it is important to electrically connect the unit and properly size fuses circuit breakers and wires in accordance with all nationa...

Page 12: ...RANGE 2 5 1121 31 1074 33 1039 34 998 35 959 37 923 882 839 T4 BLUE 3 0 1274 28 1239 28 1199 29 1166 30 1129 31 1096 1059 1021 T5 BLACK 3 0 1306 27 1261 28 1232 29 1195 29 1162 30 1132 1090 1057 T1 YE...

Page 13: ...0 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULA...

Page 14: ...the wiring diagram on the unit for the most up to date wiring GME95 XA HIGH VOLTAGE DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO S...

Reviews: