background image

PRODUCT IDENTIFICATION

2

The model and manufacturing number are used for positive identification of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.

G

M

V

M

9

6

060

3

B

X

A

A

   

   

SU

PPL

Y T

Y

PE

M

: U

p

fl

o

w

/H

o

ri

z

o

n

ta

l

C

:  D

o

w

n

fl

o

w

/H

o

ri

z

o

n

ta

l

F

U

R

N

A

C

E T

Y

PE

V

: T

w

o S

ta

ge/

  

   Va

ri

a

b

le

-S

p

e

e

d

AF

U

E

96

: 96

%

NO

M

IN

A

L

 I

N

P

U

T

0

60

  6

0

,0

00

 B

tuh

0

80

  8

0

,000

 B

tuh

100

 100

,0

00 B

tuh

115

 115

,0

00 B

tuh

  

 AI

R

F

L

O

W

 

CA

P

A

BI

L

IT

Y

 @ 0

.5

E

S

P

  

3:

 1

2

00

  

4:

 1

6

00

  

5:

 2

0

00

CA

BI

NE

T

 WID

T

H

 B:

 1

7

-1

/2

"

 C:

 2

1

"

 D

2

4

-1

/2

"

 AD

D

IT

IO

N

AL

  

F

E

AT

URE

S

N:

 N

a

tu

ra

l G

a

s

X:

  

L

o

w

 N

O

x

  

P

R

O

DUC

T

  

  

T

YPE

:

G:

 G

o

o

d

m

a

n

A

: A

m

a

n

a

®

  

  

Bra

n

d

  

    

M

A

J

O

R

  

  R

E

VI

SI

O

N

 A

: I

n

it

ia

l Re

le

a

s

e

   

   

 M

IN

O

R

   

 R

E

VI

SI

O

N

 A

In

it

ia

R

e

le

a

s

e

   

  CO

M

M

UN

IC

AT

IO

N

 F

E

A

T

UR

E

M:

 Mo

d

u

la

tin

g

 F

u

rn

a

c

e

   

  4-

W

ir

e

 C

o

m

m

u

n

ic

a

ti

o

n

 R

ead

y

Summary of Contents for CVM96 Series

Page 1: ...Catalog for part number information Model numbers listed on page 3 Copyright 2011 Goodman Manufacturing Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL A...

Page 2: ...ntal C Downflow Horizontal FURNACE TYPE V Two Stage Variable Speed AFUE 96 96 NOMINAL INPUT 060 60 000 Btuh 080 80 000 Btuh 100 100 000 Btuh 115 115 000 Btuh AIRFLOW CAPABILITY 0 5 ESP 3 1200 4 1600 5...

Page 3: ...which may result Many jurisdictions require a license to install or service heating and air conditioning equipment WARNING WARNING WARNING WARNING The United States Environmental Protection Agency EP...

Page 4: ...hen paired with a compatible communicating indoor unit and a CTK0 AA communicating thermostat these models can support 4 wire communication protocol and provide more troubleshooting information These...

Page 5: ...ITION THIS IS ALSO THE CORRECT POSITION WHEN USING A NON COMMUNICATING SINGLE STAGE THERMOSTAT U IMPORTANT NOTE As a two stage non communicating furnace the furnace inte gratedcontrolmoduleprovidester...

Page 6: ...Integrated Control Module Remote Condensing Unit Single Stage Cooling Dehumidistat Optional NEU R Thermostat Two Stage Heating with Single Stage Cooling Thermostat The modulating line of furnaces may...

Page 7: ...p 19 Coil Front Cover Drain Port 20 Drain Line Penetrations 21 Drain Trap 22 Blower Door Interlock Switch 23 Inductor Not All Models 24 Two Stage Integrated Control Module with fuse and diagnostic LED...

Page 8: ...HOLE RIGHT SIDE DRAIN LINE HOLES STANDARD GAS SUPPLY HOLE DRAIN TRAP 19 3 4 AIR INTAKE PIPE 2 PVC LEFT SIDE DRAIN LINE HOLES 1 3 4 DRAIN TRAP 1 1 2 1 5 8 30 1 4 11 3 4 19 3 16 BOTTOM KNOCK OUT 23 9 16...

Page 9: ...VOLTAGE ELECTRICAL HOLE 20 5 32 2 UNFOLDED FLANGES DISCHARGE AIR E CONDENSATE DRAIN TRAP w 3 4 PVC DISCHARGE RIGHT OR LEFT SIDE FOLDED FLANGES RETURN AIR A HIGH VOLTAGE ELECTRICAL HOLE LOW VOLTAGE ELE...

Page 10: ...156 A GCVM960805DX 0 96 0 81 0 25 0 10 0 10 0130F00070 0 81 0130F00155 GCVM961005DX 0 85 0 70 0 25 0 10 0 10 0130F00070 0 70 0130F00154 PRESSURE SWITCH TRIP POINTS AND USAGE CHART 1 Data given is leas...

Page 11: ...1 GCVM961005DX 1 PRIMARY LIMIT Part Number 0130F00038 Open Setting F 120 A GMVM960603BX 1 A GMVM960805CX 1 A GMVM961005DX 1 A GMVM961155DX 1 A GCVM960604CX 1 A GCVM960805DX 1 GCVM961005DX 1 AUXILIARY...

Page 12: ...C D heights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C...

Page 13: ...inal Filter Size in Approx Flow Area in 2 Cabinet Width in Nominal Filter Size in Approx Flow Area in 2 All 16 x 25 x 1 400 17 1 2 14 x 25 x 1 350 21 16 x 25 x 1 400 24 1 2 20 x 25 x 1 500 BOTTOM RETU...

Page 14: ...t Width Filter Area in 2 Qty Filter Size in Dimension A in 17 1 2 14 2 21 13 0 24 1 2 11 3 17 1 2 19 7 21 18 8 24 1 2 17 7 17 1 2 25 0 21 24 3 24 1 2 23 4 800 2 20 X 20 X 1 1000 2 25 X 20 X 1 Counterf...

Page 15: ...A MVM96115 5DXA CVM960604 CXA CVM960805 DXA GCVM96100 5DXA Btuh Input US 60 000 80 000 100 000 115 000 60 000 80 000 100 000 Output US 57 600 76 800 96 000 109 250 57 600 76 800 96 000 Input CAN 60 00...

Page 16: ...34 1 5 w c ESP Heating Speed Tap Adjust Tap Low Stage CFM 70 High Stage CFM Rise F Heating Speed Tap Adjust Tap Low Stage CFM 70 High Stage CFM Rise F Minus 1 107 1 629 54 Minus 1 107 1 629 62 Normal...

Page 17: ...Normal 510 Plus 869 Plus 561 Plus 869 Plus 561 Minus 990 Minus 639 Minus 990 Minus 639 Normal 1100 Normal 710 Normal 1100 Normal 710 Plus 1210 Plus 781 Plus 1210 Plus 781 Minus 1269 Minus 819 Minus 1...

Page 18: ...s 1177 Minus 1035 Minus 1287 Minus 1242 Normal 1150 Normal 1430 Normal 1380 Plus 1265 Plus 1573 Plus 1518 Minus 1323 Minus 1692 Minus 1602 Normal 1470 Normal 1880 Normal 1780 Plus 1617 Plus 2068 Plus...

Page 19: ...Minus 711 Minus 837 Minus 828 Normal 790 Normal 930 Normal 920 Plus 869 Plus 1023 Plus 1012 Minus 882 Minus 1098 Minus 1044 Normal 980 Normal 1220 Normal 1160 Plus 1078 Plus 1342 Plus 1276 1 8 w c ES...

Page 20: ...37 Plus 1 232 1 749 30 Plus 1 463 2 101 34 Heating Speed Tap Adjust Tap Low Stage CFM 70 High Stage CFM Rise F Minus 1 098 1 557 56 Normal 1 220 1 730 51 Plus 1 342 1 903 46 Minus 1 125 1 593 55 Norma...

Page 21: ...tor blower to operate at a slightly lower speed 85 of desired speed during a combined thermostat call for cooling and dehumidistat call for dehumidification This can be done through an independent deh...

Page 22: ...PPLIED WITH THE USED WHEN SERVICING 2 M ANUFACTURER S SPECIFIED REPLACEMENT PARTS MUST BE 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS BK BLACK PU PURPLE YL YELLOW BL BLUE WH WHITE BR BROWN P...

Reviews: