SERVICING
37
NOTE:
External static is for blower @ 230 Volts. It does not include Coil, Air Filter or Electric Heaters.
S-16E BLOWER PERFORMANCE DATA
SPEED
STATIC
MBR800**-*
SCFM
MBR1200**-*
SCFM
MBR1600**-*
SCFM
MBR2000**-*
SCFM
0.1
1,240
1,500
1,800
2,160
0.2
1,170
1,460
1,740
2,080
0.3
1,120
1,360
1,680
1,990
0.4
1,060
1,280
1,610
1,890
0.5
980
1,200
1,520
1,790
0.6
900
1,110
1,430
1,690
0.1
900
1,380
1,540
1,730
0.2
850
1,320
1,490
1,670
0.3
790
1,270
1,450
1,590
0.4
740
1,200
1,400
1,520
0.5
680
1,140
13,560
1,420
0.6
605
1,040
1,280
1,320
0.1
650
1,170
1,130
1,520
0.2
590
1,130
1,100
1,450
0.3
540
1,080
1,070
1,360
0.4
500
1,020
1,030
1,290
0.5
430
950
990
1,200
0.6
330
830
930
1,090
HIGH
MEDIUM
LOW
THERMOSTAT “FAN ONLY” MODE
During Fan Only Operations, the CFM output is 30% of the
cooling setting.
CFM TRIM ADJUST
Minor adjustments can be made through the dip switch
combination of 7-8.
Table 4
shows the switch position for this
feature.
NOTE:
The airflow will not make the decreasing adjustment
in Electric Heat mode.
C FM
S w it c h 7
S w it c h 8
+ 1 0 %
O N
O F F
- 1 5 %
O F F
O N
Table 4
HUMIDITY CONTROL
When using a Humidstat (normally closed), cut jumper PJ6
on the control board. The Humidstat will only affect cooling
airflow by adjusting the Airflow to 85%.
TWO STAGE HEATING
When using staged electric heat, cut jumper PJ4 on the
control board.
Model
Switch 1
Switch 2
EMERGENCY
BACKUP CFM
HEAT PUMP CFM
WITH BACKUP
OFF
OFF
1
1100
1210
AEPF1830
ON
OFF
850
935
OFF
ON
700
770
OFF
OFF
2050
2150
ON
OFF
1750
1835
OFF
ON
1600
1680
ON
ON
1200
1260
ON
ON
1020
1020
Model
Switch 5
Switch 6
EMERGENCY
BACKUP CFM
HEAT PUMP CFM
WITH BACKUP
OFF
OFF
1100
1100
AEPF1830
ON
OFF
850
850
OFF
ON
700
600
OFF
OFF
1800
1800
ON
OFF
1580
1580
OFF
ON
1480
1480
ON
ON
1200
1200
ON
ON
1020
1020
AEPF3036/4260
AEPF3036/4260
Table 5
Table 6
AEPF DIPSWITCH FUNCTIONS
1
7 - 8 shall be OFF-ON for 2.5 ton applications