HIGH VOLTAGE!

 DISCONNECT ALL POWER BEFORE SERVICING.

MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

WARNING

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

ASPF Wiring Diagram

BK

BL

B K

L1

L2

B K

BK

HTR 1

TL

HTR1

RD

9

8

7

R

W H

B L

PU

TL

B K

5

6

3

4

B K

R D

1

2

W H

RD

L2

L1

B K

B K

RD

B K

RD

R

HTR2

T L

L1

BK

6

8

9

7

2

RD

PU

4

5

3

BK

RD

1

BK

L2

L1

L2

RD

YL

M1

M2

BK

RD

YL

RD

R 1

M4

RD

BK

M3

HTR3

TL

HTR2

HTR1

TL

TL

PU

M2

R2

YL

M1

BL

WH

BR

BL

RD

BK

RD

BK

TL

HTR1

BK

HTR4

HTR3

HTR2

BK

RD

9

7

8

L2

L1

L1

L2

2

5

6

3

4

1

RD

M1

YL

BK

M2

BL

WH

6

BL

RD

BK

YL

8

9

7

M6

M5

M3

R1

M4

RD

PU

M7

R2

M8

BL

TL

TL

TL

YL

BL

RD

BK

RD

BL

BR

4

5

3

2

BK

1

ONE (1) ELEMENT ROWS

TWO (2) ELEMENT ROWS

THREE (3) ELEMENT ROWS

FOUR (4) ELEMENT ROWS

FL

M1

M2

FL

FL

M1

M2

M3

M4

FL

FL

FL

FL

FL

FL

FL

COPPER POWER SUPPLY

(USE RATING PLATE)

USE MIN. 75° C FIELD WIRE

0140A00063-B

PLM

PLF

TR

FACTORY WIRING

FIELD WIRING

NOTES:

1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON
TERMINAL "2" FOR 208 VOLTS.
2) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR
PROPER LOW VOLTAGE WIRING CONNECTIONS.
3) CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF
SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4
OF CR RELAY TO APPROPRIATE TAP AT TB
4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY.
5) FUSE: 3A, 250V, 3AG CARTRIDGE FUSE.

RELAY

EVAPORATOR MOTOR

TERMINAL BOARD

 R

EM

TB

BK

RD

BL

YL

BLUE

BLACK

RED

YELLOW

COMPONENT CODE

BROWN

PURPLE

GREEN

PU
BR

GR

FEMALE PLUG CONNECTOR
MALE PLUG CONNECTOR

TRANSFORMER

   HIGH VOLTAGE
   LOW VOLTAGE

   HIGH VOLTAGE
   LOW VOLTAGE

PLF

2

COLOR CODE

TR

6

5

PL M

4

4

2 4V

5

1

2

3

EM

WIRING CODE

208/240 V OLTS

1

1

PLF

PLM

L1

PLM

2

L2

IF REPLACEMENT OF THE ORIGINAL WIRES
SUPPLIED WITH THIS ASSEMBLY IS NECESSARY,
USE WIRE THAT CONFORMS TO THE NATIONAL
ELECTRIC CODE.

FL

FUSE LINK

TL

THERMAL LIMIT

HTR

HEAT ELEMENTS

CR

CONTROL RELAY

NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEAT ER KIT COMBINATION ON THIS
UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT,  MARK A "X" IN THE BOX PROVIDED ABOVE.  MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK
INDICATES NO HEAT KIT INSTALLED.

WHITE

WH

L G N

W 2

R

W 1

C G

4

Y1

O

Y 2

1

DH

3

2

5

A

B

1

C

EM

2

4

3

5

4

7

CR

FUSE
HOLDER
(OP TIONAL)

1

SEE NOTE 1

USE COPPER WIR E

EQUIPMEN T GROUND

BL

EM

YL

BL

5

BK

C

BK

PLF

BK

1

RD

2

3

240

24V

4

1

2

3

TR

RD

BL

BR

4

5

WH

6

7

8

9

PLM

GRD

1

2

3

4

5

6

7

8

9

A

B

1

7

4

CR

SEE

 

NOTE 2

2

1

4

3

5

N

C

G

L

RD

PU

BL

BR

WH

BL

RD

GR

RD or BK

BL

RD

BK

RD

W2

R

W1

C G

4

Y1

O

Y2

1

DH

3

2

5

RD or BK

PU

BR

WH

OR

W H

WH

BL

GR

RD or BK

BL

FUSE
HOLD ER
(OPTIONAL)

L2

L1

SEE 
NOTE 1

SEE 
NOTE 4

1

3

5

4

2

ALTERNATE HEAT RELAY

BL

PU

RD

GR

WH

BL

1

3

2

4

CR

5

ALTERNATE HEAT RELAY

Summary of Contents for ASPF Series

Page 1: ...4 Electric Heat 4 HKR Installation 4 Electrical Supply Wire and MOP 4 Building Electrical Service Inspection 5 Wire Sizing 5 Maximum Overcurrent Protection MOP 5 Electrical Connections Supply Voltage...

Page 2: ...ng Areas Carbon monoxide producing devices such as an automobile space heater gas water heater etc should not be operated in enclosed areas such as unventilated garages utility rooms or parking areas...

Page 3: ...tion of your nearest distributor consult the white business pages the yellow page section of the local telephone book or contact CONSUMER AFFAIRS GOODMAN MANUFACTURING COMPANY L P 7401 SECURITY WAY HO...

Page 4: ...19 28 37 41 2000 5 8 11 12 17 25 34 37 HEAT KIT NOMINAL kW CFM Table 2 230 1 60 Supply Voltage Temperature Rise Table F 3 5 6 8 10 15 20 21 600 17 27 34 39 800 13 20 25 30 40 1000 10 16 20 24 32 48 12...

Page 5: ...314 235 188 157 134 118 110 Based on NEC 1996 Maximum Allowable Length in Feet to Limit Voltage Drop to 2 Minimum Circuit Ampacity MCA Wire Size AWG Table 6 Maximum Overcurrent Protection MOP Every i...

Page 6: ...tched applications a flowrator piston change may be required See the Goodman piston kit chart or consult your local distributor for details regarding mix matched piston sizing If the mix match applica...

Page 7: ...rain pan NOTE The filter provision is not applicable in THIS downflow application ACCESS PANEL RETURN AIR SIDE OF UNIT REAR CHANNEL BRACKET ZEE COIL SUPPORT BRACKET COIL RETAINING BRACKET TIE BRACKET...

Page 8: ...the enclosure for external connections 1 Ensure drain pan hole is NOT obstructed 2 To prevent potential sweating and dripping on to finished space it may be necessary to insulate the condensate drain...

Page 9: ...Delivery Table 9 shows the CFM speed tap settings for the ASPF Start Up Procedure Prior to start up ensure that all electrical connections are properly sized and tightened All panels must be in place...

Page 10: ...owing composite wiring diagrams detail various con figurations in which the ASPF air handlers can be used Ex amples include single stage cooling and heat pump with single or two stage electric heating...

Page 11: ...B YL BL CONDENSING UNIT 24V CONNECTION BL YL GR RD 18 GA 5 WIRES WITH COOLING 4 WIRES WITHOUT WH YL BR BR BR YL G C R HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW C W1 W2 Y2 Y1 O G R TB 1...

Page 12: ...IT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE C W1 W2 Y2 Y1 O G R TB 18 GA 7 WIRE O Y C W2 R Y O W2 E RD GR BL OR YL YL BL OR WH BR WH BL WH WH RD BR RD WH GR YL OR OR RD OR NOTES 1 OUTDOOR THERMOSTAT...

Page 13: ...OF CR RELAY TOAPPROPRIATE TAP AT TB 4 BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY 5 FUSE 3A 250V 3AG CARTRIDGE FUSE RELAY EVAPORATOR MOTOR TERMINALBOARD R EM TB BK RD BL YL BLUE BLACK RED YELLOW...

Page 14: ...14 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 15: ...e airflow If cleaning of the outdoor coil becomes necessary hire a qualified servicer Inexperienced people could easily puncture the tubing in the coil Even a small hole in the tubing could eventually...

Page 16: ...2 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com or www amana hac com NOTE SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITH...

Reviews: