BLOWER PERFORMANCE DATA

20

ARUF

Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4%  (208V/240V)

0.1"

0.2"

0.3"

0.4"

0.5"

High

1155

1090

1025

950

895

ARUF172916

M ed.

940

890

860

815

755

Low

695

665

650

610

550

High

1155

1090

1025

950

895

ARUF182416

M ed.

940

890

860

815

755

Low

695

665

650

610

550

High

1135

1085

1025

965

915

ARUF193116

M ed.

860

825

780

750

680

Low

600

570

545

500

465

High

1385

1315

1240

1155

1065

ARUF303016

M ed.

1340

1290

1230

1140

1050

Low

1075

1030

980

910

840

High

1310

1240

1155

1090

1020

ARUF363616

M ed.

1270

1210

1140

1075

980

Low

1045

1005

955

885

805

High

1700

1660

1625

1545

1505

ARUF364216

M ed.

1500

1440

1400

1350

1345

Low

1330

1300

1250

1230

1220

High

2065

2000

1925

1860

1780

ARUF374316

M ed.

1685

1635

1550

1470

1410

Low

1490

1425

1345

1280

1205

High

2150

2120

2070

2000

1940

ARUF486016

M ed.

1940

1930

1905

1860

1790

Low

1610

1600

1590

1575

1550

High

2150

2105

2040

1970

1880

ARUF496116

M ed.

1960

1935

1895

1825

1750

Low

1670

1625

1585

1525

1455

CFM  deliverd against External Static Pressure

M odel

Speed

Summary of Contents for ACNF

Page 1: ...ge 3 TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL AL RT6121000r19 November2012 Copyright 2007 2012 Goodman Company L P This manual is to be used by qualified p...

Page 2: ...1 2 Tons 1830 1 1 2 3 1 2 Tons 10 SEER 1729 1 1 2 2 1 2 Tons for export systems The model number is used for positive identification of component parts used in manufacturing Please use this number whe...

Page 3: ...TUF363616 ATUF364216 ATUF374316 ATUF486016 The United States Environmental Protection Agency EPA has issued various regulations re garding the introduction and disposal of refrigerants introduced into...

Page 4: ...appliance can be installed in the vertical or right horizon tal position without modification The horizontal left and downflow positions require product modification This product is designed for zero...

Page 5: ...multi position multi speed with di rect drive motors They are available in 1 1 2 to 5 ton sizes with optional 3 kW to 21kW electric heat kits available for field installation See note below ARUF is a...

Page 6: ...PRODUCT DIMENSIONS 6 ACNF DIMENSIONS Model A B C D ACNF18 37 3411 16 30 6 ACNF24 43 4011 16 36 6 ACNF30 49 4611 16 42 6 AC18 37 3411 16 30 6 AC30 43 4011 16 36 6 AC36 49 4611 16 42 6...

Page 7: ...1 4 1 4 1 4 1 4 1 4 1 4 Ship Weight lbs 59 59 59 59 69 69 69 69 69 79 79 79 79 79 ACNF DA with aluminum coils ACNF AA AB copper coils ACNF180016 ACNF180516 ACNF180616 ACNF180816 ACNF240016 ACNF240516...

Page 8: ...051 High 935 880 810 735 675 Low 720 680 630 565 490 ACNF24061 High 935 880 810 735 675 Low 720 680 630 565 490 ACNF24081 High 935 880 810 735 675 Low 720 680 630 565 490 ACNF24101 High 935 880 810 73...

Page 9: ...860 800 725 670 Low 850 800 725 680 600 High 1 060 985 895 805 720 Low 905 845 780 710 625 High 1 060 985 895 805 720 Low 905 845 780 710 625 High 1 060 985 895 805 720 Low 905 845 780 710 625 High 1...

Page 10: ...NS 10 ADPF 2 Model A B C D E F G H I L M ADPF18241 16 42 22 13 15 10 3 61 16 13 1715 16 15 155 16 ADPF30421 16 53 24 20 22 12 9 1113 16 19 1915 16 217 16 21 ADPF48601 16 53 24 20 22 12 9 1113 16 19 19...

Page 11: ...53 253 Blower Motor FLA 1 70 2 95 4 30 HP 1 3 1 2 3 4 Ship Weight lbs 100 131 160 208V 240V ADPF Note Assumes dry coil with filter in place SCFM correction for wet coil 4 208V 240V 0 1 0 2 0 3 0 4 0 5...

Page 12: ...46 3 4 22 17 1 2 19 1 2 10 14 1 2 11 15 16 17 1 8 17 15 16 2 AEPF30361 16 53 1 4 24 20 22 12 19 5 8 11 15 16 19 5 8 19 15 16 1 13 16 AEPF31371 16 53 1 4 24 20 22 12 19 5 8 11 15 16 19 5 8 19 15 16 1...

Page 13: ...4 3 4 Lineset Connection Size Liquid 3 8 3 8 3 8 3 8 Suction 3 4 7 8 7 8 7 8 Electrical Data Voltage 208 240 208 240 208 240 208 240 Min Circuit Ampacity 2 5 2 5 3 1 3 1 3 1 3 1 7 8 7 8 Max Overcurre...

Page 14: ...ement ON OFF Increases selected Cool Heat Pump airflow by 10 OFF ON Decreases selected cool Heat Pump airflow by 15 NOTE Other setting have no effect on the set airflow 8 Trim CFM Adjust Mode Trim CFM...

Page 15: ...8 17 15 16 2 ARPF36361 46 3 4 22 17 1 2 19 1 2 10 14 1 2 11 15 16 17 1 8 17 15 16 2 ARPF36421 53 1 4 24 20 22 12 14 1 2 11 15 16 19 5 8 19 15 16 1 13 16 ARPF37431 53 1 4 24 20 22 12 14 1 2 11 15 16 19...

Page 16: ...3 253 253 253 Blower Motor FLA 1 70 1 48 2 64 2 64 HP 1 3 1 4 1 3 1 3 Ship Weight lbs 120 155 144 164 ARPF36421 ARPF37431 ARPF48601 ARPF49611 Blower Diam eter 10 5 8 11 15 16 10 5 8 10 5 8 W idth 8 10...

Page 17: ...50 Low 1075 1030 980 910 840 High 1310 1240 1155 1090 1020 ARPF36361 M ed 1270 1210 1140 1075 980 Low 1045 1005 955 885 805 High 1700 1660 1625 1545 1505 ARPF36421 M ed 1500 1440 1400 1350 1345 Low 13...

Page 18: ...2 11 15 16 17 1 8 17 15 16 2 ARUF303016 46 3 4 22 17 1 2 19 1 2 10 14 1 2 11 15 16 17 1 8 17 15 16 2 ARUF363616 46 3 4 22 17 1 2 19 1 2 10 14 1 2 11 15 16 17 1 8 17 15 16 2 ARUF364216 53 1 4 24 20 22...

Page 19: ...1 70 1 48 2 64 HP 1 3 1 3 1 4 1 3 Ship Weight lbs 110 120 155 144 ARUF363616 ARUF364216 ARUF374316 ARUF486016 ARUF496116 Blower Diameter 9 1 2 10 5 8 11 15 16 10 5 8 10 5 8 Width 6 8 10 11 16 10 5 8...

Page 20: ...1065 ARUF303016 M ed 1340 1290 1230 1140 1050 Low 1075 1030 980 910 840 High 1310 1240 1155 1090 1020 ARUF363616 M ed 1270 1210 1140 1075 980 Low 1045 1005 955 885 805 High 1700 1660 1625 1545 1505 AR...

Page 21: ...16 46 3 4 22 17 1 2 19 1 2 10 14 1 2 11 15 16 17 1 8 17 15 16 2 ASPF303616 53 1 4 24 20 22 12 19 5 8 11 15 16 19 5 8 19 15 16 1 13 16 ASPF313716 53 1 4 24 20 22 12 19 5 8 11 15 16 19 5 8 19 15 16 1 13...

Page 22: ...3 4 3 4 Lineset Connection Size Liquid 3 8 3 8 3 8 3 8 Suction 3 4 7 8 7 8 7 8 Electrical Data Voltage 208 230 208 230 208 230 208 230 Min Circuit Am pacity 3 6 3 6 3 8 3 8 3 9 3 9 6 4 6 4 Max Overcu...

Page 23: ...820 785 765 745 705 ASPF183016 3 920 900 850 840 815 4 1075 1055 1015 975 960 5 1130 1115 1085 1040 1000 1 1060 865 600 515 420 2 1105 910 795 745 690 ASPF303616 3 1165 1070 1020 960 915 4 1285 1240...

Page 24: ...11 15 16 17 1 8 17 15 16 2 ATUF303016 46 3 4 22 17 1 2 19 1 2 10 14 1 2 11 15 16 17 1 8 17 15 16 2 ATUF363616 46 3 4 22 17 1 2 19 1 2 10 14 1 2 11 15 16 17 1 8 17 15 16 2 ATUF364216 53 1 4 24 20 22 1...

Page 25: ...um VAC 197 197 197 197 Maximum VAC 253 253 253 253 Blower Motor FLA 1 70 1 48 2 64 2 64 HP 1 3 1 4 1 3 1 3 Ship Weight lbs 120 155 144 164 ATUF364216 ATUF374316 ATUF486016 Blower Diameter 10 5 8 11 15...

Page 26: ...1 070 ATUF363616 Med 1 270 1 210 1 140 1 075 980 Low 1 045 1 005 955 885 805 High 1 700 1 680 1 645 1 610 1 535 ATUF364216 Med 1 500 1 480 1 440 1 380 1 325 Low 135 1 320 1 275 1 230 1 195 High 2 065...

Page 27: ...6 A 36 B 20 3 8 B 24 C 16 1 8 C 21 D 16 D 19 7 8 E 11 E 15 7 8 FILTER 14 X 18 X 1 FILTER 16 X 20 X 1 Small Chassis AWUF 18 24 Large Chassis AWUF 30 36 A 36 B 24 C 21 D 19 7 8 E 15 7 8 FILTER 18 X 20 X...

Page 28: ...253 253 253 253 253 Blower Motor FLA 1 30 1 35 1 35 1 30 1 35 1 35 1 35 1 58 1 58 1 58 1 58 HP 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 3 1 3 1 3 1 3 Ship Weight lbs 84 84 84 84 84 84 84 93 93 93 93 240V 208V AW...

Page 29: ...l Drain Connection FPT 3 4 3 4 3 4 3 4 3 4 3 4 Lineset Connection Size Liquid 3 8 3 8 3 8 3 8 3 8 3 8 Suction 5 8 5 8 5 8 5 8 5 8 5 8 Electrical Data Min Circuit Ampacity 26 6 23 3 39 6 34 6 15 1 17 3...

Page 30: ...785 745 700 T2 645 615 550 500 445 T1 645 615 550 500 445 T5 1090 1065 1040 1015 985 T4 1005 975 945 920 890 T3 840 795 785 745 700 T2 645 615 550 500 445 T1 645 615 550 500 445 High 1280 1190 1110 10...

Page 31: ...NSTALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH WIRING DIAGRAMS 31 Wiring is subject to change Always refer to the wiring...

Page 32: ...structions for proper low voltage wiring connections Notes DELAY RELAY STRAIN RELIEF EVAPORATOR MOTOR ELECTRONIC BLOWER TIME RUN CAPACITOR SR EM EBTDR RC BK RD BL YL BLUE BLACK RED YELLOW COMPONENT CO...

Page 33: ...TL TL TL YL BL RD BK RD BL BR 4 5 3 2 BK 1 TWO 2 ELEMENT ROWS THREE 3 ELEMENT ROWS FOUR 4 ELEMENT ROWS FL FL M1 M2 M3 M4 FL FL FL FL FL FL FL USE COPPER WIRE EQUIPMENT GROUND BL SEE NOTE 3 BR BR RC EM...

Page 34: ...HEAT CUT PJ2 ADD OT18 60 TO OTC OT2 2 FOR TWO STAGE ELECTRIC HEAT APPLICATIONS CUT PJ4 USE ONLY ON 15 20 KW MODELS 4 FOR SINGLE STAGE COOLING APPLICATIONS CONNECT THERMOSTAT TO Y Y2 ONLY TAPE OR REMO...

Page 35: ...ONNECTTHERMOSTATTOY Y2ONLY TAPEORREMOVEY1CONNECTION CONNECTCONDENSINGUNITTOYCON C 6 REDWIRESTOBEONTRANSFORMERTERMINAL3FOR240VOLTSANDONTERMINAL2FOR208VOLTS 1 FORHEATPUMPAPPLICATIONSREMOVEORANGEJUMPERWI...

Page 36: ...s for proper low voltage wiring connections Notes DELAY RELAY RELAY EVAPORATOR MOTOR ELECTRONIC BLOWER TIME TERMINAL BOARD R EM EBTDR TB BK RD BL YL BLUE BLACK RED YELLOW COMPONENT CODE BROWN PURPLE G...

Page 37: ...ing diagrams in installation instructions for proper low voltage wiring connections Notes DELAY RELAY RELAY EVAPORATOR MOTOR ELECTRONIC BLOWER TIME TERMINAL BOARD R EM EBTDR TB BK RD BL YL BLUE BLACK...

Page 38: ...NSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS 3 CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION IF SPEED TAP NEEDS TOBE CHANGED CONNECT PURPLE WIRE FROM TERMINAL 4 OF C...

Page 39: ...NAL 4 OF CR RELAY TO APPROPRIATE TAP AT TB 4 BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY 5 FUSE 3A 250V 3AG CARTRIDGE FUSE RELAY EVAPORATOR MOTOR TERMINAL BOARD R EM TB BK RD BL YL BLUE BLACK RE...

Page 40: ...DS RD BK BR RD WH BR RD RD PU NOTE SEE 3 RD RD RD DISC EQUIPMENT GROUND RD R1 M1 M2 BR BK BK BK BL M3 M4 RD DISC BL 3 5 RD 1 2 TR BK HTR2 HTR1 BK BK TL1 TL1 RD RD TL2 TL2 COLOR CODE WIRING CODE BT1493...

Page 41: ...ALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH WIRING DIAGRAMS 41 Wiring is subject to change Always refer to the wiring dia...

Page 42: ...NG CONNECTIONS 4 ASTERISK INDICATES THAT HEATING ELEMENT THERMAL LIMIT RELAY SEQUENCER AND INTERCONNECTING W IRES AND JUMPERS OF HEATER 2 AR E DELETED WITH SINGLE ELEMENT UNITS 5 COLOR CODE W H W HITE...

Reviews: