Goodman 36F22 User'S Information Manual Download Page 2

S

IGNAL

 W

ORDS

Dear Homeowner, please recognize the following safety informa-
tion.  This information will alert you to the potential for personal
injury.

WARNING

 - Indicate hazards or unsafe practices which 

COULD

result in severe personal injury or death.

T

HIS PRODUCT CONTAINS OR PRODUCES A CHEMICAL OR CHEMICALS WHICH

MAY CAUSE SERIOUS ILLNESS OR DEATH AND WHICH ARE KNOWN TO THE

S

TATE OF 

C

ALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER

REPRODUCTIVE HARM.

 

WARNING

WARNING

T

O AVOID POSSIBLE EQUIPMENT DAMAGE, PERSONAL INJURY, FIRE OR

DEATH, THE FOLLOWING INSTRUCTIONS MUST BE OBSERVED REGARDING UNIT

LOCATION, AIR REQUIREMENTS AND OPERATING PROCEDURES. 

Before using this manual, check the serial plate for proper

model identification.

The installation and servicing of this equipment must be

performed by qualified, experienced technicians only.

G

ENERAL

 I

NFORMATION

U

NIT

 L

OCATION

This unit is approved only for an outdoor installation. See the
installation instructions for the required clearances to the unit. It is
important that safety measures are taken in the surrounding area
of the unit.

Gutters or deflectors must be installed on the roof to prevent water
from shedding on the unit.

1. An area must be available to reach the unit in a clear and unob-

structed path.

2. The unit area and the vicinity of any other gas appliances must

be kept clear and free of combustible materials, gasoline, and
other flammable vapors and liquids. Also, do not store or use
flammable items such as paint, varnish, or lacquer in the area.

3. The combustion air supply must not be contaminated by prod-

ucts containing chlorine or fluorine, as they could corrode the
heat exchanger. If you need further information on this subject,
contact your installing dealer or another qualified servicer.

4. Familiarize yourself with the controls that turn off the gas and

electrical power to the unit.

5. Establish a regular service and maintenance schedule to en-

sure efficient and safe operation of the unit.

6. The unit must be placed where no runoff water from higher

ground can collect in the unit.

U

NIT

 I

NSTALLATION

Examine the unit installation to determine the following:

1. The flue hood connector is in place and is physically sound

without holes or excessive corrosion.

2. The mounting pad support of the unit is sound.

3. There are no obvious signs of deterioration of the unit.

4. The burner flames are stable, soft and blue, (dust may cause

orange tips but must not be yellow). The flames should extend
directly outward from the burner without curling, floating, or lift-
ing off.  To examine, turn on the electrical power and gas.  Set
the room temperature to the maximum setting.

Check the burner flames for: 
1. Good adjustment
2. Stable, soft and blue 
3. Not curling, floating, or lifting off. 

Burner

NOTE:

  If a strong wind is blowing, it may not be possible to perform

the flame inspection.

Summary of Contents for 36F22

Page 1: ...Installer Affix this manual Installation Guide and Warranty adjacent to the appliance Owner Read and keep all product literature in a safe place for future reference WARNING SHOULD OVERHEATING OCCUR O...

Page 2: ...es must be kept clear and free of combustible materials gasoline and other flammable vapors and liquids Also do not store or use flammable items such as paint varnish or lacquer in the area 3 The comb...

Page 3: ...safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vacinity of this or any other appliance nstal...

Page 4: ...est utilise un incendie ou une explosion peut se produire II faut avoir recours a une entreprise d entretien qualifiee pour faire inspecter l appareil de chauffage et remplacer toutes les commandes de...

Page 5: ...ure HEATING SHUT DOWN To shut down operation follow the steps listed below 1 Set the thermostat to the lowest setting 2 Turn OFF electrical power to the unit 3 Remove the heat exchanger door on the si...

Page 6: ...cket and monitors the burner flame If there is an improper draw of burner flames into the heat exchanger the rollout limit will detect it and shut off gas flowing to the burners Contact a qualified se...

Page 7: ...nts Ensure the area is clean and free of dirt and debris REPLACING OR CLEANING FILTER IMPORTANT NOTE Never operate unit without a filter installed as dust and lint will build up on internal parts resu...

Page 8: ...RICA ANTES DEL MANTENIMIENTO SERVICING B14933 36 SAFETY LABELS NOTE If safety labels are missing or illegible contact the installing dealer To obtain the proper safety labels the Model and Serial Numb...

Page 9: ...rveau et meme la mort Cette ventilation est n cessaire pour viter le danger d intoxication au CO pouvant survenir si un appareil produisant du monoxyde de carbone continue de fonctionner au sein de la...

Page 10: ...10 THIS PAGE LEFT BLANK INTENTIONALLY...

Page 11: ...r reproductive harm are known to the This product contains fiberglass insulation State of California to product could expose California to cause known by the State of contains a chemical Fiberglass in...

Page 12: ...se cancer birth defects or other reproductive harm are known to the This product contains fiberglass insulation State of California to product could expose California to cause known by the State of co...

Page 13: ...13 SAFETY LABELS because some gas is heavier than air and will...

Page 14: ...14 THIS PAGE LEFT BLANK INTENTIONALLY...

Page 15: ...15 THIS PAGE LEFT BLANK INTENTIONALLY...

Page 16: ...16 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com...

Reviews: