![Goodix GT911 Programming Manual Download Page 14](http://html1.mh-extra.com/html/goodix/gt911/gt911_programming-manual_2243136014.webp)
GOODIX CONFIDENTIAL
Reproduction and/or distribution of this document in whole or in part is strictly prohibited without written consent of GOODIX.
14
0x8140
R
Product ID ( first byte
,
ASCII )
0x8141
R
Product ID ( second byte
,
ASCII )
0x8142
R
Product ID ( third byte
,
ASCII )
0x8143
R
Product ID ( forth byte
,
ASCII )
0x8144
R
Firmware version ( HEX. low byte )
0x8145
R
Firmware version ( HEX. high byte )
0x8146
R
x coordinate resolution ( low byte )
0x8147
R
x coordinate resolution ( high byte )
0x8148
R
y coordinate resolution ( low byte )
0x8149
R
y coordinate resolution ( high byte )
0x814A
R
Vendor_id ( ID of the current module )
0x814B
R
Reserved
0x814C
R
Reserved
0x814D
R
Reserved
0x814E
R/W
buffer status
large detect
Proximity
Valid
HaveKey
number of touch points
0x814F
R
track id is 32, indicates the signal is proximity sensing signal
0x8150
R
PxyOk
Reserved
0x8151
R
PxyOk
Reserved
0x8152
R
Reserved
0x8153
R
Reserved
0x8154
R
Reserved
0x8155
R
Reserved
0x8156
R
Reserved
0x8157
R
track id
0x8158
R
point 1 x coordinate (low byte)
0x8159
R
point 1 x coordinate (high byte)
0x815A
R
point 1 y coordinate (low byte)
0x815B
R
point 1 y coordinate (high byte)
0x815C
R
Point 1 size (low byte)
0x815D
R
point 1 size (high byte)
0x815E
R
Reserved
0x815F
R
track id
0x8160
R
point 2 x coordinate (low byte)
0x8161
R
point 2 x coordinate (high byte)
0x8162
R
point 2 y coordinate (low byte)
0x8163
R
point 2 y coordinate (high byte)
0x8164
R
point 2 size (low byte)
0x8165
R
point 2 size (high byte)
0x8166
R
Reserved
0x8167
R
track id