GoBeam 5100 Quick Installation Guide
UM000018 Rev 1.0
6.
Ground the GoBeam 5100 Unit
Connect the 10 AWG
grounding cable
before connecting any
other cables. When
removing the GoBeam
5100, the grounding
cable should be the
last cable removed.
Connecter la prise de terre 10 AWG avant de connecter tout autre
câble. Pendant la désinstallation du GoBeam 5100, la prise de terre
doit être le dernier câble retiré.
7.
Connect the Ethernet PoE
Pin # Signal
1 Data
2 Data
3 Data
4 48V
(+)
5 48V
(+)
6 Data
7 48V
(-)
8 48V
(-)
8.
Connect the 1Gbps Network Connection
When using 1Gbps Network
connection, use the Eth 1000
port as shown.
Pin # Signal Color
1 BI_DA+ white & green
2 BI_DA-
green
3 BI_DB+ white & orange
4 BI_DC+ blue
5
BI_DC- white & blue
6 BI_DB-
orange
7 BI_DD+ white & brown
8 BI_DD-
brown
Eth 1000 Port
1G Network Cable