7
CONNECTION DIAGRAM
8
NOTICE
1. While connecting a new monitor to the splitter, experiencing a short period of time without display
might be expected. The splitter will do Automatic EDID learning which analyzes the newly connected
monitor to see if the EDID for the HDMI input is necessary to update!
2. Firmware update is proceed through Micro-USB
System firmware update
(1) Save the firmware file (.bin) & software in the same folder.
(2) Please try to adjust dip switch [pin1, pin 2]=[
↑
-
↑
]
(3) Connect the Micro-USB cable between PC and device
(4) Open firmware update software and then device will start to update firmware automatically.
(5) After update process is done, software will show
“Success” message and then be closed
automatically.
(6) Power cycle the device
Output 1 firmware update
(1) Please adjust dip switch [pin1, pin 2]=[
↓
-
↑
]
(2) Connect the Micro-USB cable between PC and device
(3) Open the firmware update software
(4) Set the correct COM port and baud rate (57600 is recommended)
(5) Click the FILE button to load firmware file (.hex or .bin file)
(6) Device power on
(7) Press Program MCU symbol to do firmware update
(8) Once update process is done, please power cycle the device and set the dip switch [pin 1, pin 2] to
[
↑
-
↑
]
(9) Power cycle the device