OPERATION
Continued from previous page.
10
VESTA7 SE GB2 - VESTA7 SE GB2/H MONITOR
1.
Doctor mode function (automatic door opening):
6
'
'
The 'doctor mode' function enables lock release 1 to be activated automatically 7 seconds after making a call from the
door panel without having to establish communication or press door release 1 button
. The main monitor will display
the door panel image without alerting the visitor. The call ends after 40 seconds and the channel is free. If there is an
M-IP-GB2 memory module, it will automatically take a photo or record a video 4 seconds after receiving a call from the
door panel (for video, a 16GB Class 10 MicroSD card is required,
) and the LED of button
will blink
indicating that a photo/video is pending viewing.
not supplied
Descrip
n:
tio
Enabling 'doctor mode':
To enable doctor mode, enter function code [9018] in the installer menu (see pp. 22 and 24).
Activating 'doctor mode':
To activate doctor mode, the monitor must be in standby mode. Then press button
for 6 seconds, the LED of
button
will blink to indicate that the doctor mode function is activated.
Deactivating 'doctor mode':
To deactivate doctor mode, the monitor must be in standby mode. Then press button
for 6 seconds, the LED of
button
will turn off to indicate that the doctor mode function is activated.
Important:
When deactivating 'do not disturb' mode (with the monitor's 'doctor mode' activated), the status LED will blink and the
'doctor mode' function will be reactivated.
When activating 'do not disturb' mode (with the monitor's 'doctor mode' activated), the status LED will change from
blinking to fixed and the 'doctor mode' function will be cancelled.
1.5 Answering a call from the door panel and showing cameras (DQ-CAM-GB2 module required):
When a call is received, the monitor(s) will play a melody and show the door panel image on the master monitor without
alerting the visitor. If there is an M-IP-GB2 memory module, it will automatically take a photo or record a video (for
video, a 16GB Class 10 MicroSD card is required,
) and the LED of button
will blink indicating that a
photo/video is pending viewing. To answer the call, press button
. If the monitor is a Vesta2 SE GB2/H with icon
on the front, make sure that the hearing aid is 20cm away from the monitor to ensure maximum audio quality during
communication with the door panel.
not supplied
.
Communication will last for one and a half minutes or until button
or
is pressed again.
In call or communication: selects from the door panel the image of the camera(s) in ascending mode and in
carousel (DQ-CAM-GB2 module required).
Viewing the image of the door panel or camera(s) from the
monitor enables the opening of door 1/2 and audio with the door panel in case of communication.
Note:
DS-1
00:30
DS-1
00:30
01
Start/stop communication.
To open door 1, press the door release button during
the call: one press will activate the lock release for
5 seconds.
To open door 2, press the door release button during
the call: one press will activate the lock release for
5 seconds.
[ ]
9018