D
escription of the TEKNA S PLUS monitor.
D
escription of the connection terminals.
I
nstallation of the terminal
DESCRIPTION
INSTALLATION
DESCRIPTION
Avoid dusty or smoky environments or locations near sources of heat.
The monitor can be fixed to an electrical embedding box or directly to
the wall.
I
mportant:
For further information, see the TTekna S
Plus manual (code 50122251).
WIRING DIAGRAM
1
2
3
Monitor for the Plus system with button and coded panels.
F
unction buttons.
With the monitor in standby and the handset on the hook: One long 2-
second press activates 'ringtone volume' mode, with a tone indicating
the current volume selected. Then each long 2-second press (before
5 seconds elapse) selects a volume level: maximum, no volume 'night
mode,' minimum and medium, and so on (carousel mode). Note: The
'night mode' status LED blinks red.
With the monitor in standby (handset on or off the hook), call or
communication: One long 3-second press turns off the monitor. Then
one short 1-second press turns on the monitor.
OPERATION
-
To establish communication, lift the handset of the monitor, and the monitor's
status LED (green) and the door panel's LED
will illuminate.
Communication with hearing aids
: The handset of the monitor enables
communication with hearing aids equipped with T-mode. Note: Set the
hearing aid switch to the T position, making conversation possible (inductive
loop).
-
Call reception: During call reception, the image will appear on the monitor(s)
and the status LED on the master monitor will illuminate (green). If the call is
not answered within 45 seconds, the master monitor's status LED will
illuminate (red), LED
on the door panel will turn off and the channel will
become free.
-
The communication will last for one and a half minutes or until the handset is
replaced. After communication, the monitor's status LED will illuminate
(red), the door panel's LED will turn off and the channel will be free.
-
To open the door, press door release button
during the call or
communication processes: one press will activate the lock release for 3
seconds and LED
will also illuminate for 3 seconds.
I
https://doc.golmar.es/search/manual/ 50122328
MPORTANT:
For further information about the door panel, sections, distances, wiring diagrams, etc., see the T632 Plus P/T manual.
FA-Plus/C or FA-Plus
SEC
PRI
~
~
Mains
+ +
-
-
*
Place this power supply as
close as possible to the
first monitor.
Access panel
M =Master.
D
Mesh
V
in-
A
in
A
out
V
in+
V
out-
V
out+
CN1
+
- +
CV1
CV2
-
10
1
9
2
8
3
7
4
6
5
CN3
DC lock
release
M
SW1
SW2
1.60m
Screws supplied with
he embedding box.
Embedding box
Location
Remember to remove the protective covering from
the front of the monitor once installation is
complete.
Surface
With the monitor in standby and the handset on the hook: This makes a
panic call to the guard units configured to receive such calls.
With the monitor in standby and the handset off the hook: It enables a
normal call to the main unit to be made.
During call reception and communication processes, it enables the lock
release to be activated.
This activates auxiliary device 'A1' with the monitor in standby (handset
on or off the hook), call, communication or intercom.
In advanced programming mode, the default functions of function
buttons
and
can be changed (see the TTekna S Plus manual).
( )
*
Audio communication.
Digital communication.
Door bell button input.
Input for auxiliary door opening button.
Intercom function.
Output for 2nd camera activation.
Output (negative) for auxiliary device activation
(max. consumption 50mA).
Output (negative) for auxiliary call repeater
(max. consumption 250mA).
A :
D :
HZ- :
AP+ :
INT :
2C
A1 :
SA :
CN3 connection terminals:
Negative, positive (18Vdc power supply).
Video signal input through coaxial cable.
Coaxial cable
.
shield
Video signal output through coaxial cable.
Balanced video signal (through twisted pair).
–
:
Vin :
:
Vout :
, +
–
Vp, Mp :
CN2 connection terminals:
_
A
D
HZ
-
+
SA
2C A1
_
AP+
INT
With the handset off the hook: This activates the intercom (in the same
apartment); one long press until a confirmation tone can be heard will
call all of the monitors in the apartment. To call individual devices,
press the button once to call the 'master' monitor, twice to call 'slave 1'
and so on up to 5 presses to call 'slave 4.' This only functions if no call
or communication is in progress. Note: With Tekna Plus monitors (see
the TTekna S Plus manual).
With the monitor in standby and the handset off the hook: It enables
audio and video communication with the door panel to be established
if it has its auto switch-on function activated. This only functions if no
communication is in progress.
In call: A slave monitor enables the image of the door panel to be captured.
With the monitor in standby and the handset on the hook: This enables
the image from the door panel configured as main to be viewed (if the
bus is busy, the status LED of the monitor will indicate so with a few
quick blinks).
Remove the JP1 jumper
from all of the distributors
except the last.
A
_
+
D
V
in
V
out
CN4
E
E
D1
D1
D2
D2
+
+
D4L-PLUS
D4L-PLUS
JP1
JP1
S
S
A
_
+
D
V
in
V
out
Tekna S Plus
A
_
+
D
V
in
V
out
A
_
+
D
V
in
V
out
(1)
(1)
x
4 30
a.
b.
c.
d.
e.
f.
g.
i.
h.
Handset.
Communication with hearing aids. Set
the hearing aid switch to position T.
Function/programming buttons.
Telephone cord.
Brightness control.
4.3
”
TFT colour screen.
Colour control.
Advanced programming LED.
Cord connector.
Monitor status LED (two-colour):
-
No volume (night mode):
-
Communication: Green LED ON.
RJ-45 connector (installation with
UTP cable).
CN3 connection terminals.
-
In standby: LED illuminated red.
-
Call: LED illuminated green
(master monitor).
-
Auto spy if Bus busy:
LED blinking red rapidly.
-
Doctor mode: LED blinking
green.
LED blinking red.
Connector fixings.
CN4 connector (end of line jumper).
JP1 jumper, remove in video
installation with twisted pair (see
the TTekna S Plus manual, code
50122251).
SW1 configuration switches.
CN2 connection terminals.
j.
p.
o.
m.
k.
n.
q.
l.
k
q
m
n
p
o
JP1
1 2 3 4 5 6 7 8 9 10
CN2
CN3
SW1
l
k
f
75
Ω
TEKNA-S PLUS
11742126
V XX
.
15090200000
SN
ADDRESS
INTER
A1
SLAVE MASTER
ATENCIóN
Alta tensión. No abrir la tapa.
Manipular sólo por personal
de
vicio técnico.
l ser
WARNING.
GOLMAR S.A
High Voltage. Don´t open cover
C/ Silici, 13
Handle only by technical service
08940 - SPAIN
ESCALERA
STAIR
PISO
FLOOR
PUERTA
DOOR
CN4
CN4
Tekna S Plus
CN4
Tekna S Plus
CN4
Tekna S Plus
M
M
M
M
( )
*
( )
*
a
b
c
d
j
i
h
g
e
+
_
Vin
MP
Vout
VP
Shield
*
( )
*
( )