47
ACCESS CONTROL PROGRAMMING
46
ACCES CONTROL PROGRAMMING
nter and exit from
E
programming.
rogramming structure
P
and sequence.
To enter into the programming menu, press key symbol and enter
the installer PIN code (factory default: 271828)
or the user PIN code (factory default: 314159).
To exit from the programming menu press key symbol at any moment.
On both cases, the module will reproduce 5 fast acoustic tones.
To program the access control functions, it will be necessary to enter the function field
followed by the corresponding value. Sometimes, this value will be predefined
(i.e. relay 1 contact type) and sometimes will be selected by the installer.
Once into programming mode, the programming sequence is as follows:
If a wrong value has been introduced, press cancel key (C). The keypad will reproduce 1 large
acoustic tone. If cancel key has been pressed during the introduction of the function field,
even after the confirming tones, the function field must be entered again; if cancel key
has been pressed during the introduction of the function value, introduce a new value.
Enter the function field to be programmed: this is a
2 digits code. The module will reproduce a 2 slow
acoustic tones.
Enter the value of the function under programming.
Once the value has been entered, the module
will reproduce a 4 slow acoustic tones.
Enter the next function field to be programmed or
press key symbol to exit from the programming mode.
or
4
1
5
1
3
9
8
2
8
1
8
2
8
1
7
1
2
1
1
5
1
3
9
9
C
C
C
C
C
2
4
unction fields and values.
F
The module is delivered with factory default values: for security reasons, the relay activation
codes are delivered with a non valid value. For a proper system operation, check that
all the values match your requirements.
It's not necessary to program the functions in the same order as they are shown.
It defines the lenght of the relay activation codes.
Accepted lengths are 4, 5 or 6 digits.
Factory default: 4 digits.
Any modification of this value will delete
the existing relay activation codes.
It defines the 1st activation code of the relay n.1.
Enter a code according with the number of digits
defined on 00 field.
It defines the 2nd activation code of the relay n.1.
Proceed as detailed on 11 field.
It defines the 3rd activation code of the relay n.1.
Proceed as detailed on 11 field.
It defines the 4th activation code of the relay n.1.
Proceed as detailed on 11 field.
It defines the 5th activation code of the relay n.1.
Proceed as detailed on 11 field.
It defines the 6th activation code of the relay n.1.
Proceed as detailed on 11 field.
5
6
*
4
*
or
or
0
1
2
3
4
5
6
0
1
1
1
1
1
1
Continue