6. DEVICE CONFIGURATION THROUGH THE WEB CLIENT
to configure the device, it will be necessary to connect to its web client, as it is not possible to configure iton the device itself as it lacks a screen
or button panel.
We will connect with the web browser to the device IP address, which will be the
10.0.0.253
as its settings are in factory default values.
5.1. Settings
Reader
About
Se�ngs
LIFT CONTROL
Relay Mode **
** Relay modes
Delay request
1000
Ac�va�on �me
5
Delay �me
0
0 Normally Open - 1 Normally Closed
1 Basic - 2 Advanced
Name
Block number
1
Unit number
1
Opera�on mode*
1
* Opera�on mode
0
Relays operation mode.
(0 Normally open - 1 Normally closed)
Unit name..
Block number. (1-98)
Group number. (1-5)
Operation mode.
(1 Basic - 2 Advanced)
Save configuration set.
5. DEVICE OPERATION
To be able to use the LCU-16/G+ it will be necessary to enable it in every device of the installation, you can visit the installer manual of the
different devices in the website of each prduct, accessing the “Downloads” dropdown..
There are two operation modes of the lift controller unit which will be detailed below:
- Basic mode:
In this mode the device only enables the corresponding relay to the floor where is located the device which the magnetic key that is pre-
sented in the keybuss is associated, or when a door opening after a call from the entry door panel.
- Advanced mode:
In the advanced mode, the lift controller unit enables the corresponding relays to the destination floor and origin floor. Those will be ena-
bled when a magnetic key presentation in the entry panel RFID reader (relays of the entry panel and of the apartment number enabled),
when a call to the lift from the apartment monitor (relay of the apartment floor number enabled twice), when invite your neighbor during
an intercom process (relay of the guest apartment number and relay of the host apartment number enabled) and when a door opening in
a call from the door entry panel (relays of the entry panel and of the apartment floor number enabled).
Delay request (ms).
(Only in advanced mode)
Activation time.
(Basic mode (s) - Advanced mode (ms )
Delay time.
(Basic mode (s) - Advanced mode (ms )
Explanatory graphic Activation-Time
Act.
t (s)
Act.
t (ms)
0
0
1
Delay time
Activation time
Activation time
Delay time
Delay
request
Basic Mode
Advanced Mode
Activation time (máx. 300s).
Delay time (máx. 120s).
Activation time (100 - 5000ms).
Delay time (100 - 5000ms).
Delay request (100 - 5000ms).