2
SAFETY PRECAUTIONS
- Hands-free monitor.
- 4,3
olo r
.
" TFT c
u screen
- Monitor with Wifi transmission for call forwarding to a smartphone
(no additional power supply
needed for WI-FI functionality)
.
.
-
for access and selection of menu function.
Function push buttons
- Monitor
.
with simple installation (non-polarised 2 wires bus)
-
.
User menu
.
-
.
Installer menu
.
-
.
Image and communication settings menu
.
-
50mA/12V
).
Output auxiliary call repeater (max.
dc
.
- "HZ" input for calls from apartment front door.
.
- Push buttons for door release 1 and 2.
.
-
eds.
Notification l
.
-
call
(1 to 128)
end of line.
Configuration switches to assign the
address
and
- Function codes to define whether the monitor is master or slave (default: master).
-
before installing or making modifications to the device.
Always disconnect the power supply
.
- The fitting and handling of these devices must be carried out by
.
authorised personnel
.
- The wiring must run at least
40 cm. away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
- Always follow the instructions contained in this manual.
CHARACTERISTICS
SYSTEM OPERATION
*
( )
*
( )
3
DESCRIP
MONITOR
TION
Monitor address (code) setup:
*
( )
*
( )
*
( )
INSTAL A
MONITOR
L TION OF THE
*
( )
Building / Villa (Nexa Door Panel)
*
( )
EN
EN
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that the
call is being made and
LED
will turn on. If vocal synthesis is enabled, a 'Call is in
door panel
progress' message appears indicating that a call is being made. At this moment, the apartment's
monitors receive the call. If another apartment is called by mistake, press the button for the correct
apartment and the first call will be cancelled.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon
displayed on the screen
green
. To view the
in
colour
image from slave monitors 2 or 3, press
. If the
one of the buttons of the monitor to display the image
call is not answered within 45 seconds,
LED
will turn off and the system will become free.
door panel
- To establish communication, press
icon
o
the screen. The icon
the button below
sh wn on
displayed on the screen in red colour, door panel LED
will turn off and the led
will turn on.
- Co
will last for 90 seconds or until
on-the-hook icon
mmunication
the button below
shown on the
screen is
door panel
pressed. When communication ends,
LED
will turn off and the system will
become free. If vocal synthesis is enabled, a 'Communication is finished' message will indicate that
the call is over.
-
, press the
corresponding icon
To open door
of the door panel
on
or
button below the
displayed
the screen
3
during the call or communication processes: one press will activate the lock release for
seconds and
LED
will also turn on for seconds. If vocal synthesis is enabled, a 'Door
door panel
3
is open' message will be indicated on the door panel.
-
and configuration
, see "TART W LITE/G2+" user manual
Detailed operation
of the monitor
4
.
1
2
For more information, see
“
TART 4
/G2+ user manual (code 50122
)
”
.
W LITE
639
https://doc.golmar.es/search/manual/50122639
ART W LITE/G2+
4
MONITOR
Dip1 Dip7:
-
Sets the monitor address (addresses to
).
1
2
1 8
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Dip8:
This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
Switch number:
1 2 3 4 5
6
7
:1 2 4 8 16 32 64
Value when ON
Table of values
Important:
Apartment 1 (Dip1 to ON & Dip2-Dip to OFF)
7
.
Important:
Apartment 2 (Dip1 - Dip to OFF).
1 8
7
1
2
3
ON
Example: 0 + 0+4+0+16+
= 20
0+0
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
Dip 8 a ON
1
2
3
ON
4
5
6
7
8
Dip 8 a OFF
Not :
e
To de
fi
ne whether the monitor is master or slave, entering the corresponding
“
Special code
”
:
"0550" Master (factory default),
1,
2
3
”
0551" Slave
“
0552" Slave or
“
0553" Slave .
For more information, see
“
TART 4
/G2+ user manual (code 50122
)
”
.
W LITE
639
https://doc.golmar.es/search/manual/50122639
ART W LITE/G2+
4
MONITOR
A.
.
Speaker
B.
Function buttons, access and selection of menu functions.
The function of each button is shown on the monitor screen with an
icon located just above each button (see
“
TART 4
LITE/G2+
”
W
manual).
Press to access 'Doctor mode' function (standby monitor):
- With the special code '0441' (Doctor mode) already entered
(see special codes i
), press
n manual
“
TART 4
LITE/G2+
”
W
the button for 1 sec. to activate/ deactivate the function.
- The push button led
will blink in white colour and the icon
will be displayed in the main menu if the function 'Doctor mode'
is activated and it will turn off if the function is deactivated.
C.
LED:
Monitor status
Yellow ON: Standby without notification.
Red ON:
“
Do not disturb
”
Mode a tivated.
c
D
. 4.3" TFT colour screen.
E.
Golmar use.
F.
.
Microphone
G.
people.
Raised dots for the visually impaired
In call
:
/communication
Above this raised dot is the 'Start/ nd communication' button.
E
Above these raised dots is the 'Door opening' button.
H.
Configuration switches.
I.
.
Installation terminals
J.
Wall mounting connector fixing (x4).
*
A
D
B
C
J
H
I
J
J
J
SA
GND
HZ
HZ
O
N
1
2
3
4
5
6
7
8
BUS
G
BUS
E
F
SA
OFF = 0
ON = 1
DIP 1 to 7
DIP 8
Monitor
address
EOL
resistor
GND
HZ
HZ
BUS
BUS
128
codes
Villa (Soul Door Panel)
Dip1 to Dip :
7
These assign the address of the monitor to call button on the door panel.
Switches - must remain in the OFF position.
2 7
See quick guide enclosed with the Kit Soul Art 4W Lite.
Note:
Apartment 1
Dip8:
This activates the end-of-line resistance in the ON position. Activate it in monitor where the bus cable ends.
Deactivate it only in intermediate monitors.
1
2
3
ON
4
5
6
7
8
Dip 8 a ON
1
2
3
ON
4
5
6
7
8
Dip 8 a OFF
Not :
e
To de
fi
ne whether the monitor is master or slave, entering the corresponding
“
Special
code
”
: "0550" Master (factory default),
1,
2
3
”
0551" Slave
“
0552" Slave or
“
0553" Slave .
1
2
3
ON
4
5
6
7
8