Installation
ART 7W/G2+ MONITOR
Installation terminals (K)
For ease of installation, the installation terminals are removable and supplied in a separate bag. Once the
terminals are wired, place them in position.
BUS BUS
,
: communications bus (non-polarised).
24V,
: local power input.
GND
SA GND
,
: auxiliary call repeater output (maximum 50mA/12V).
HZ HZ
,
: apartment front door button input:
Note: ART 7W/G2+ monitor 'V.01 + No. 6539 and V.02' or later:
Connect only on the master monitor. The signal received is then
transmitted to the slave monitors in the same apartment through the BUS.
SA
GND
HZ
HZ
BUS
BUS
24V
GND
ON
1
2
3
4
5
6
7
8
Configuration switches (R)
Master
Slave 1
Slave 2
Slave 3
Switches 6 and 7:
These define whether the monitor is master or slave. Each apartment must have one master
monitor, and only one. In the case of apartments with more than one monitor, the monitor with Wi-Fi transmitter
should always be the master.
Switch 8:
This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
Switches 1 to 5:
Sets the monitor address (addresses
to 3 ).
1
2
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Avoid dusty or smoky environments or locations near sources of heat.
3. Pass the installation wires through the middle hole and connect them to the removable terminals as shown in the
wiring diagrams. Before connecting the removable terminals to the monitor, configure the switch as indicated
below.
2. If you are going to use an embedding box to pass the wiring through, make sure that it is in line with the holes
corresponding to the box model chosen and fix the connector. If you prefer to fix the connector directly to the
wall, make four 6mm holes at the points indicated (A), insert the wall plugs supplied and screw in the connector.
4. Connect the removable terminals to the monitor and place the monitor in front of the connector, making sure the
fixings line up. Move the monitor downwards to secure it.
For proper installation, use the template supplied with the product.
1. Position the top of the template at a height of 1.65m.
ART
MONITOR
7W/G2+
Note: HZ push button function mode (ART 7W/G2+ monitor
"V.0
or later):
5"
When HZ push button is pressed will
be call tone and activate the output of auxiliary call repeater with standby monitor call process
m
ation
process HZ tone with lower audio level
process and "Do not disturb" mode
,
, com unic
(
), intercom
.
Important:
Up to 8 monitors/
apartments with push button "HZ" activated at the same time (with system and monitors in standby).
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
4
5
6
7
8
1
2
3
ON
Example: 0+ 0+4+0+16 = 20
Switch number:
1
2
3
4
5
Val
ON:1
2
4
8 16
ue when
Table of values
4
5
6
7
8
Important:
Apartment 1 (Dip1 to ON & Dip2-Dip5 to OFF)
ART 7W/G2+ monitor
.
with V.04 and later
Important:
Apartment 32 (Dip1 - Dip5 to OFF)
*
Villa (Soul Door Panel)
*