If after starting the system it's considered that
     the audio volume isn't correct, proceed
     with the necessary adjustments as shown.
Use the included pan mechanism to adjust
     the telecamera position.

LOCK RELEASE INSTALLATION

nstalling the FA-PLUS and FA-PLUS/C power supplies.

I

DIN 46277

f

3,5 x  25

DIN-7971

 

f

3,5 x 25

DIN-7971

If the lock release will be installed in a metal door, use a
     

Ø3,5mm. drill and tap the hole. In case of wood door,

     use a 

Ø3mm. drill.

IMPORTANT: the lock release to be used must be of 12Vd.c.

If you are using a.c. lock releases, use one R-3 relay unit and
one TF-104 transformer to activate it, as it is shown on page 19.

M 4 x 8

f

3,5 x 25

 DIN-7972 

 DIN-963

DOOR PANEL INSTALLATION

POWER SUPPLY INSTALLATION

lace the nameplate labels.

P

lose the door panel.

C

Fix the door panel to the embedding box
     by using the supplied vandal resistant screws
     and the special screwdriver.

inal adjustments.

F

To install the power supply directly on the wall, drill two holes
     of 

Ø6mm. and insert the wallplugs.

     Fix the transformer with the specified screws.

The power supply can be installed on a DIN 46277 guide
     simply pressing it. To disassemble the power supply
     from the DIN guide, use a plain screwdriver to lever
     the flange as shown on the picture.
The FA-Plus/C model uses 6 units over DIN guide
     and 10 units the FA-Plus model.

IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power

supply is 10, and 50 units in case of a FA-Plus model.
Link power supplies to connect more units than the specified as it's shown
on page 19.

The power supply must be installed in a dry and
     protected place. It's recommended to protect
     the power supply by using a thermo-magnetic
     circuit breaker and to use a ground connection.

ock release installation.

L

Summary of Contents for 295 Series

Page 1: ...T300EN rev 0204 Instructions manual Audio and Video door entry system digital installation 295 Series...

Page 2: ...roubleshooting hints 29 INTRODUCTION First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar The commitment to reach the satisfaction of our cu...

Page 3: ...thout the visitor being aware of this To see the picture in a slave monitor press the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system wil...

Page 4: ...CD 295 2nd push buttons module CD 295 2nd push buttons module CD 295 L1 L2 CD1 CN2 CD2 CP L1 L2 CN1 CP CD L1 L2 CN1 CP CD 1 9 17 3 11 19 5 13 21 7 15 23 8 16 24 6 14 22 4 12 20 2 10 18 DOOR PANEL INS...

Page 5: ...eneral entrance panel this function can be activated in one door panel of each internal building Set to ON the switch number 2 for monitor or telephones programming Once the programming progress is fi...

Page 6: ...el C Fix the door panel to the embedding box by using the supplied vandal resistant screws and the special screwdriver inal adjustments F To install the power supply directly on the wall drill two hol...

Page 7: ...O Floor Door Stair PLATEA Plus 0000000000 N serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachmen...

Page 8: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L561 module for video installations E with twisted pair cable andling the end of line jumper H hang...

Page 9: ...e In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release pu...

Page 10: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description T positive ground audio d...

Page 11: ...slaves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished s...

Page 12: ...econd panel as shown on the diagram In case of more than two door panels wire them as the second is connected 1 00mm 2 50mm 0 25mm 0 25mm RG 59 RG 59 Terminal SECTIONS CHART 50m Distance 150m A A A D...

Page 13: ...M in out p d p d CV CV CTO CT For longer distances than the specified contact with your distributor ideo installation without coaxial cable v The installation diagram shows the connection of a video s...

Page 14: ...door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the di...

Page 15: ...connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminals 17...

Page 16: ...wiring from the door panel and to check a monitor or telephone directly connected to the door panel No shortcircuit will damage the connected units with the exception of a shortcircuit between CTO and...

Page 17: ...el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golma...

Reviews: