Summary of Contents for X500A

Page 1: ...RALIAN MADE INSTALLATION PROCEDURE USER MANUAL SERVICE INSTRUCTION MODEL X500A I I I I I I Ii ELECTR CAL APPROVAL CS GAS APPROVAL SC 378 I Goldstein I ESTABLISHED t911 The Cooking Equipment Professionals www goldstaineswood com au I i ...

Page 2: ...e 8 CONTROLS Page 9 TECHNICAL INSTRUCTIONS Page 10 TECHNICAL DATA Page 11 12 13 ELECTRICAL CONNECTION Page 14 GUIDE FOR COOKING TIMES TEMP Page 15 CLEANING INSTRUCTIONS Page 16 17 PROBLEM SOLVING Page 18 19 20 WIRING DIAGRAM Page 21 22 CONNECTION DIAGRAM Page 23 BLOWER WHEEL FAN Page 24 DRAWINGS Page 25 SPARE PARTS Page 26 WARRANTY Page 27 BRANCHES Page 28 IM067B2 p2 ...

Page 3: ...STEIN GAS CONVECTION OVENS are designed to give long and satisfactory service and incorporate the best possible materials and workmanship Proper installation adjustment and preventative maintenance are vitally important if efficiency and appearance are to be maintained Read these instructions carefully as they contain important safety information regarding the installation use and maintenance of t...

Page 4: ...k check and level side to side first then front to back this is important as floors can be out 75mm of level ELECTRICAL CONNECTION The electric motor indicator light and related switch are all connected to a terminal block found at the top of the oven The supply cord must be plugged into a properly ground three prong receptacle Do not cut or remove the grounding prong from the plug Normal factory ...

Page 5: ...gulations of the local Gas Authority AS56011AG601 and any other authority having jurisdiction The appliance has been tested and preset before leaving our factory but small adjustments may be necessary to suit local conditions Correct operation of the appliance must be tested as part of the installation procedure Check Page 7 Commissioning Licensed Gas Fitter should make connection to main gas line...

Page 6: ... notify your dealer immediately B Check gas pressure at Test nipple on the outlet side of the 830 SIT Control The control pressure e g as on Page 12 should be 0 92 Kpa on Natural gas and 2 75 Kpa on LP gases When checking gas Test Point Pressure be sure other equipment on the same gas line is ON This will allow you to set the T P P while the oven is under a high load T P P can be adjusted using a ...

Page 7: ... ON GAS ADJUST GAS PRESSURE WITH THREE QUARTERS OF THE UNIT RUNNING ADJUST GAS PRESSURE NATURAL GAS 1 00 KPA as per pressure shown LPG 2 75 KPA on Rating P ate TURN ON ONE AT A TIME TO MAKE SURE ALL IS WORKING E G BURNER RADIANT GRIDDLE AND STEAMER SHOW CUSTOMER A HOW TO WORK EQUIPMENT B HOW TO CLEAN C HOW TO PULL IT APART E G TRAYS TRIVETS D ALSO WHAT NOT TO DO E G GREASE AND OIL IN CONTROLS CHEC...

Page 8: ...top of the goods allowing the heat to penetrate more quickly thus shortening the cooking time and permitting use of lower temperatures Cook the product in less time than it would take to bake in a Static or Normal oven Depending on the item and the type of pan used time saving may run from 20 to a high of 50 A damper lever on the control panel keeps steam in when you want moist heat but permits yo...

Page 9: ...dicate that it is in the setting mode it will stop after the button has been released and will display the set cooking time viii Press the button so that the green LED lights up This will start the cooking cycle which will operate until the set time has elapsed and the buzzer sounds m ix Cook Hold Press the button It will hold the oven temperature at 70 C after the cooking cycle finishes for up to...

Page 10: ...re in position Peel off all protective plastic and remove any glue with a solvent IMPORTANT READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE LIGHTING AND USE GAS INLET CONNECTION 19mrn NB BSP from below the appliance 6gram from the right hand side looking at the front of the appliance as shown on Page 11 Electrical connection is a two 2 metre Three 3 pin flexible lead as shown on Page 11 As from Ist ...

Page 11: ...ator Servo system pressure regulator Ignition restart interlock Inlet outlet pressure test point Illustrated on Page 12 13 CONVERSION TO L P GAS 2 3 4 5 6 7 Disconnect oven from gas electrical supply Install LPG governor as per AGA Code AS45631AG300 Change burner injector as per table Connect gas and electrical supply Start oven to see burner flame Set T P P as per table Step through installation ...

Page 12: ...so XS A FRONT VIEW SIDE VIEW TOP VIBN eo WATER NET QPI N q nm lain 1 GAS fN r 1 llnm B p J ELECTRICAL ON OVERALL DIMENSIONS OVEN IMrERIOR POWER CONNECTION J APPROXI NO WIDTH DEPTH HE WIOTH DEPTH HE GIn GAS ELECTR mm mm mm MJ 24OVItPH t 415V 3 5 PIN IM067B2 p12 ...

Page 13: ...i functions gas valve suitable gas for aJ ff ree families The valve may be used on automat ap cas All a tmen s can be made ore the top face and me valve can be moutAed in emy posAion I I I i I I I j SPECI P 1101 I I I I I I I I tMOB7B2 pl3 I I ...

Page 14: ...tions particu ty e th have been ca f ed out Noperly Carry out aa w ing according to the instructions of the me supe lc system and that of e appliance used I AH electric sa bi devices e g flame supetvIsK n I dt sw ch e must cut Use of plug 0 960 107 recommended Bm m I 2 B ck Common Ea u YeltowlGree I Two widng examples are shown below M T L h I I I I I IMO67B2 p14 I ...

Page 15: ...UCTS Sheet Cakes 16 x26 Biscuits Pie Crust Fruit Pies Custard Type Pies Meringue topping for pies ScoRes Muffins Danish Rolls Hamburger Buns 20 rain 8 12 rain 8 10 min 30 min 30 45 rain 8 10 min 8 10 min 12 15 rain 10 rain 20 min 160 175 200 180 150 160 160 175 200 160 175 160 MISCELLANEOUS PRODUCTS Baked Potatoes 250g Toasted Cheese Sandwiches Casseroles 12 x20 x2 pan Casseroles 12 x2O x4 pan Ric...

Page 16: ...nd damage of flare up during cooking Use a mild cleaner CAUSTIC cleaners ARE NOT TO BE USED otherwise warranty will be void When cleaning the stainless steel surface under NO circumstances should wool brushes or scraping implements of common steel be used on the stainless steel because ferrous particles can deposit on the stainless steel surface causing by their oxidation rust spots I Scotchbdte c...

Page 17: ...nt m panel with wrench Grasp blower and tip forward into oven compartment i With motor and panel inside remove cover plate in rear of motor m and disconnect wires 4 MOTOR LUBRICATION None required motor is self lubricating 5 MOTOR REPLACEMENT Follow step in No 3 in reverse 6 MICRO SWITCH REMOVAL Shut off main power supply Remove top nosing trim 4 screws and disconnect wires from micro switch top R...

Page 18: ...ion of pilot orifice c Cause Extreme over gassing of main Burners i d Cause Defective thermocouple I e Cause Defective safety shut off valve I 3 Burner goes out and flashes back a Cause Excessive aeration 4 I I a Yellow Flame Cause Too much gas to burner Remedy Clean pilot orifice Remedy Check burner jet orifice Governor adjustment Remedy Replace Remedy Replace Remedy Refer to Servicing instructio...

Page 19: ...uch top heat which results in Dark top of baked products and light bottom possibly not baked in centre a Cause Excessive BTU MJ input Remedy Check burner injector orifice for correct size also check governor pressure b Cause Under active flue or flue restriction Remedy Check for obstruction in flue way c Cause Remedy Thermostat calibration too high Re calibrate Uneven baking characteristics from s...

Page 20: ...re in place b Cause Unit not level front to back Dried out Product c Cause Too low a temperature Remedy Using spirit from front to back level up appliance by means of adjustab e feet Remedy Adjust thermostat accordingly b Cause Too long a baking time Remedy Adjust cooking time and temperature to suit product Check gas pressure I I IM067B2 p20 I ...

Page 21: ...OATI M I r v m 41 mw L m k t kr m D 01 XS SCHEMATIC WIRING DIAGRAM NGNe N T X500 E08 I O RI II ...

Page 22: ... l o PO i 4 3 I E 1 Ol o 6L q 2 TOL W O CAS G BRAHMA GAS CONTROL U IT o r s t WIRING DIAGRAM N T S CAS G 09 ...

Page 23: ...LUE n BLACK WHITE BROWN T N GRN YEL NO A AEI I ENT L DATe BY Specific In oM JtGNo TO dl e ro atk lrchange tl bb lead o IOL RAN CE50P O WF JE mr E EC CO TO A D llE CH CY SCAU Of 4 G NO o o l NTS EMO12 E1 ...

Page 24: ...Goldstein I 14 BLOWER WHEEL FAN I LU I IMO67B2 p24 ...

Page 25: ...Goldstein0 Ia I ls DRAWINGS I l IB MODEL XS00 A II 9 14 J 28 i 31 L29 39 40 33 32 41 MODEL VARIATION PARTS 27 IM067B2 p25 43 342 ...

Page 26: ...MTH00288 ESWS30W0 ESW520B0 ETMS3000 MFA00003 GBNX500 PF 00P33 GIJTP400 GIJTP225 GIJTPH00 DESCRIPTION TRAY CASSETTE FAN PANEL ASSEMBLY BLOWER WHEEL MOTOR 6 MF CAPACITOR MAIN SWITCH FILTER MICRO SAFETY SWITCH KNOB PC BOARD FEET SIS SIS HANDLE SOLENOID ELECTRODE WITH LEAD BURNER INJECTOR 1 70mm L P INJECTOR 2 60mm N G BRAHMA BOX RELAY TUNNEL DISPENSER CONTROL 830 ROUND SWITCH K THERMOCOUPLE DOOR GASK...

Page 27: ...his undertaking covers the provision of labour and parts for 12 months from the date of delivery to the purchaser This undertaking applies only to state capitals Remote areas are not covered by this commitment and special enquiries should be made N Travel time not covered by warranty To the maximum extent permitted by law any liability on Goldstein Eswood s part or on the part of its servants or a...

Page 28: ...Road Moorabbin Victoria 3189 Phone 93 9553 1488 Fax 03 9553 0785 Queensland Nautilus Complex Unit 12 210 Queensport Road Murarrie QId 4172 Phone 07 3890 1811 Fax 07 3890 1788 South Australia Suite 26 283 287 Sir Donald Bradman Drive Brooklyn Park South Australia 5032 Phone 08 8238 3423 Fax 08 8238 3400 Western Australia Unit 1 10 Wittenberg Drive Canning Vale Western Australia 6155 Phone 08 9456 0...

Reviews: