background image

Air Cooled Wok-All Models May 2011 

16 

            

 

 

11.  

WARRANTY 

 

 
 
 
Installation  must  be  carried  out  according  to  local  regulations  by  qualified  trade 
persons. 
 
Isolating  switch(es),  shut-off  valves  etc  must  be  within  easy  reach  of  the  machine 
for future service and maintenance requirements.   
 
If  in  doubt  call  GOLDSTEIN/ESWOOD  or  their  representative  for  further 
information.  No responsibility will be accepted for defects or damages by improper 
installation, for changes to the product not authorised by GOLDSTEIN/ESWOOD or 
for operation outside the technical specifications.  
 
GOLDSTEIN/ESWOOD warrants their products to be free from defects in material 
and  workmanship  under  “normal  use  and  service”.    This  does  not  include  normal 
wear  and  tear  of  parts.    GOLDSTEIN/ESWOOD  will  repair  or  replace  any  parts, 
which  in  GOLDSTEIN/ESWOOD’s  sole  judgement  are  defective  in  material  or 
workmanship, in accordance with the warranty offered. 
 
This  undertaking  covers  the  provision  of  labour  and  parts  for  12  months  from  the 
date  of  delivery  to  the  purchaser.    This  undertaking  applies  only  to  state  capitals.  
Remote areas are not covered by this commitment and special enquiries should be 
made.  

(Note: Travel time not covered by warranty). 

 

“To the maximum extent permitted by law, any liability on Goldstein/Eswood’s part 
or on the part of its servants or agents for loss or damage of any kind whatsoever in 
connection with the products, including liability for or in respect of any claim arising 
out of contract, negligence or statute, shall not, in any event, exceed $100” 

 
Labour under warranty is supplied free of charge during normal working hours, 
Monday to Friday.  Should warranty work be requested outside of our normal 
working hours a labour charge will be applied equivalent to a normal hour rate, 
without out of hours penalty rates.  (Refer to last page of this manual for your 
closest branch for warranty repair services).

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

Summary of Contents for CWA

Page 1: ...OKING RANGE AIR COOLED AIR COOLED AIR COOLED AIR COOLED PROUDLY AUSTRALIAN MADE INSTALLATION PROCEDURE USER MANUAL SERVICE INSTRUCTION CW CW CW CWA A A A ALL MODELS ALL MODELS ALL MODELS ALL MODELS ESTABLISHED 1911 The Cooking Equipment Professionals www goldsteineswood com au ...

Page 2: ...5 3 COMMISSIONING Page 6 4 CLEANING MAINTENANCE OF CHINESE WOK Page 7 5 CONVERSIONS INSTRUCTIONS Page 8 6 HOURLY GAS CONSUMPTION Page 9 7 OVERALL DIMENSIONS WEIGHTS Page 9 8 PROBLEM SOLVING Page 10 9 FLOW CONTROL TAP ASSEMBLY Page 11 10 DRAWINGS SPARE PARTS Page 12 13 14 15 11 WARRANTY Page 16 12 BRANCHES Page 17 ...

Page 3: ...e long and satisfactory service and incorporate the best possible materials and workmanship Proper installation adjustment and preventative maintenance are vitally important if efficiency and appearance are to be maintained Read these instructions carefully as they contain important safety information regarding the installation use and maintenance of the appliance RECEIVING INSPECTION Check crates...

Page 4: ...rs due to exceeding 250Mj Note AFTER ANY MAINTENANCE OR ADJUSTING OF GAS CONNECTED COMPONENTS A GAS LEAK TEST MUST BE CARRIED OUT TO ENSURE THERE ARE NO GAS LEAKING HAZARDS Adequate ventilation must be provided by a hood with vent and exhaust fan Check the rating plate to ensure appliance is suitable for the gas supply to which it will be connected and for information relative to gas input pressur...

Page 5: ...ust always be greater than the drain outlet from the appliance Drain connection is 51 mm BSP 4 All gas equipment MUST have an exhaust hood as per AS5601 AG601 5 WATER CONNECTION The unit is fitted with a flow controlled timer tap to control the flow of water to the swivel arm at the rear The appliance must be connected to a cold water supply with pressure between 2 and 5 bar 300 kPa to 750 kPa ...

Page 6: ...o suit local conditions Ensure that the pressure at the pressure test point on the manifold is as per the rating plate If the two values are not the same use a screwdriver to adjust the pressure regulator turning screw clockwise will increase the pressure Flame Failure Turn the control knob to low and check that the flame size has decreased substantially If flame has not decreased then using a sma...

Page 7: ...llages should be immediately cleaned up For the cleaning of the stainless steel or vitreous enamel surfaces use hot soapy water and a soft cloth Never use an abrasive cloth A CLEANER THAT IS COMPATIBLE WITH ALUMINIUM MUST BE USED ON THE EQUIPMENT OTHERWISE THE GAS PIPING WITHIN THE UNIT WILL BE DAMAGED AND THIS WILL AUTOMATICALLY VOID THE WARRANTY SERVICE An authorised person must handle any servi...

Page 8: ... Adjust needle valve to achieve desired pilot flame size 3 Disconnect regulator from gas supply line disconnect natural gas regulator from gas line reconnect LPG regulator on line 4 Reset pressure test point on manifold 5 Adjust burner aeration if applicable Relevant required gas pressure for use in conversion Natural 1 0 kPa W G L P 2 5 kPa W G AN AUTHORISED GAS FITTER MUST CARRY OUT GAS CONVERSI...

Page 9: ...47 1 05 1 75 Mongolian 90 1 10 16 off 75 0 68 16 off Duck Bill 120 1 20 18 off 105 0 7 18 of Side burner 26 2 35 1 off 25 1 4 1 off 7 OVERALL DIMENSIONS WEIGHTS BURNER Height mm Width mm Depth mm Weight kg CWA1 1280 650 850 55 CWA1B2 1280 960 850 90 CWA2 1280 1200 850 100 CWA2B2 1280 1510 850 135 CWA3 1280 1875 850 145 CWA3B2 1280 2180 850 180 ...

Page 10: ...egulator Clean or replace c Look at ports on burner may be blocked clean or drill out d Burner may be blocked inside pull out and clean e Check injector size Rating plate 2 Flame too high a Check gas pressure on TPP on Manifold behind S S front should be 1 0 kPa NG 2 5 kPa LPG b Only part of burner works Clean ports or injectors c Check size of injector on Rating Plate 3 Water not draining from tr...

Page 11: ...mbly 1 You will receive the unit with the plastic nozzle removed Fig 1 2 The nozzle consists of 4 parts 3 Place all parts inside the nozzle but for the washer which goes over the threaded area in fig 1 4 Screw in nozzle with internal parts and assembly is complete fig 3 Fig 1 Fig 2 Fig 3 ...

Page 12: ...Air Cooled Wok All Models May 2011 12 22 17 16 15 19 12 11 7 21 9 20 18 13 5 4 2 3 1 14 8 10 6 24 23 25 26 10 DRAWING SPARE PARTS MODEL CWA CWA2 CWA3 CWA B2 CWA 282 CWA 3B2 ...

Page 13: ...ER NG 9 WW 00P04 PILOT BRACKET FOR JET BURNER 10 GPICWA01 PILOT NG 11 WW 00A02 TOP RING 12 WW 00P11 STRAINER 13 WW 00P21 SUPPORT BRACKET FOR DRIP TRAY 14 MTAC0600 WATER SPOUT 15 WW 2 P08 TOP TRAY 16 WW 2 P09 HEAT SHIELD 17 CW 00P07 SHELF BRACKET 18 WW 00P10 WATER HOLDER 19 WW 00A01 TOP RING ASSY 20 WW 00P15 PILOT BRACKET 21 CW 00P20 LEG BRACKET 22 CW 00T02 S S LEGS 23 GPI00002 2 WAY PILOT FOR DUCK...

Page 14: ...Air Cooled Wok All Models May 2011 14 2 1 8 12 11 10 9 3 4 13 5 6 7 MODEL VARIATION PARTS NEW CHINESE WOK SIDE BURNERS CWW2 10 DRAWING SPARE PARTS MODEL CW B2 BOILING TOP ...

Page 15: ... N21 3 GBNSP001 BURNER SUPPORT BRACKET 4 GTCI0600 THERMOCOUPLE 600mm 5 GTCI0450 THERMOCOUPLE 450mm 6 PFPTA001 ALUMINIUM FRONT PILOT TUBE 7 PFPTA002 ALUMINIUM REAR PILOT TUBE 8 GIJBT INJECTOR BOILING TOP 9 PF 00P33 AIR INLET CONTROL 10 GTR00002 TRIVET PF66 11 GBNCWL00 BURNER CW SIDE LONG 12 GBNCWS00 BURNER CW SIDE SHORT 13 GPI00001 SINGLE PILOT ...

Page 16: ... in material or workmanship in accordance with the warranty offered This undertaking covers the provision of labour and parts for 12 months from the date of delivery to the purchaser This undertaking applies only to state capitals Remote areas are not covered by this commitment and special enquiries should be made Note Travel time not covered by warranty To the maximum extent permitted by law any ...

Page 17: ...ld New South Wales 2164 Phone 02 9604 7333 Fax 02 9604 5420 Victoria Queensland 47 Stubbs Rd Nautilus Complex Kensington Unit 12 Victoria 3031 210 Queensport Road Murrarie Qld 4172 Phone 03 9372 6577 Phone 07 3890 1811 Fax 03 9372 6477 Fax 07 3890 1788 Western Australia Unit 2 9 Meares Way Canning Vale Western Australia 6155 Phone 08 9456 0559 Fax 08 9456 0554 ...