background image

Service and Repair Form

 

The name of the owner 

 

 ……………………………………………………………………………

 

 

Date

 ……………………………………………………………………………….

 

 

Detector/Model

 

…………………………………………………………………………………

 

 

Serial No

 

…………………………………………………………………………………….. 

 

 

The seller company

 

………………………………………………………………………… 

 

 

Buying Date

 ……………………………………………………………………….. 

 

 

Delivered piece(s)  

 

………………………………………………………………….. 

 

…………………………………………………………………………………………
…….. 

 

 
Address 

……………………………………………………………………………………….. 

 

…………………………………………………………………………………………
…….. 

 

 

Telephone (…..)……………………………………..…………………………… 

 

 
GSM:.…………………………………………………………………………………

 

Fax:……………………………………………………………………………… 

 

E-mail  

………………………………

@

……………………………………………………. 

 

 

Problem description

(Please write the problem that causes your device to not 

work.)  

 

……………………………………………………………………………………. 

 

…………………………………………………………………………………….

 

 

…………………………………………………………………………………….

 

Summary of Contents for GT18+

Page 1: ...Goldstar GT18 User guide ...

Page 2: ...Buttons 7 Menu Settings 8 Programs 9 GR Program 10 Delay Program 11 Auto dynamic Searching 12 Pointing target 12 Explicationing the target 13 14 Gold program 15 Grapich Screen 15 Metal Discriminator 16 Parasite Causes and Solution 17 18 Graphics of Depth 19 Technique of Excavation 20 Charging the Battery 20 Warranty and Maintenance ...

Page 3: ...setted very often which puts the user in difficult situations The products has been tested in many fields within the scope of Gold Technology Research and Development First of all it is tested by master users in many soil conditions and released after many tests and stages Despite that the comments of our users are important for us In this sense the entire Research and Development process is carri...

Page 4: ...rd harsh Soil conditions DLY Great stability for collective metal searching Gold program Program for only gold Various sounds Graphic bar and oscilloscope screen Different frequency setting around electricity and high voltage Working Frequency 1000 Hz 1khz Working Voltage 12V 7Ah battery Bar indicator for Signal strength Metal conductivity value between 0 99 2 level of screen brightness Protection...

Page 5: ...GoldStar 5 Package Content Main Unit Carrying Bag 38 cm Coil 90 cm Header Charger Headphones External Battery User Manual 2 Years Warranty Additional equipment 45 cm coil 120x120 cable 2x2 Pipe Header ...

Page 6: ...o this wrong it can still work but there will be soil influence pay attention to this 5 Switch on off You should press this button for 2 3 seconds to open after connecting the battery When you switch it off you should press it for 4 5 seconds 6 Screen Setting After the device is switched on if you cannot see anything on the screen you can use this button to set up the screen and you will be able t...

Page 7: ...he brightness of screen It has 2 stages Zero ve Soil Setting Zero It resets the device Also helpful to get rid of parasites ZERO in Delay Program You only need to press zero button once in DLY delay mode You will see a Zero text near to the battery icon That means it is ready Especially in delay auto1 mode if the signal balance is broken down you only need to press the Zero In auto3 mode it resets...

Page 8: ...cts the stability Level 4 for Sensitivity is recommended FIL Setting for Filter It has 5 stages Removes the parasite effects As filter got high a little bit delay will be in signals but it enables clear signals If the FIL is 0 it means it is disabled We recommend you to set it up in the level 4 in closed places and near to the electiricity cables In delay and ground mode level 3 is recommended TRS...

Page 9: ... Delay Delay has a ground effect and is deeper than the ground program You should keep a distance between ground and coil in Delay program Take the distance between coil and ground as a reference when you reset the device in Delay Program Dont move it up or down when you reset When you move the coil down to ground device gives increasing signal sound During the search keep the device in constant h...

Page 10: ...ll be on the screen Now open GR1 mode by pressing GR Button Set the device AUTO3 SNS5 FİL3 TRS7 Soil setting button should be looking up If there is parasite find the optimal frequency Now you can lower the coil to the ground If there is metal on the ground it will give sound so check if it gives sound reaction on a ground where there is no metal If there is reaction set the device sns4 trs6 If th...

Page 11: ... bit turn it right until you get less reaction When you set your coil you can start using it by keeping the distance If you do not have ground effect while starting the first adjustment you do not need to turn the soil setting button Move slowly take your time Change your frequency setting if there is unnecessary increase in magnetic environments where parasite may be very high Or you can set your...

Page 12: ...mall waste will give a double tone mixed sound When you swing from four directions on the target even one aspect of it giving a doubled sound indicates that it is worthless Although there are sometimes mistakes you will get rid of many unnecessary targets with the right results This will save both time and effort It will give a fuller breathing sound in precious bulk metals Auto4 5 resets faster b...

Page 13: ... the strength of the signal increases When the target reaches the center of the coil the signal strength decreases When the cable encounters directly under the other pipe the signal increases again These signals indicate that there is a small metal on the surface Metals in this signal are generally between 0 50 cm 2 Short time weak signal The sound given in this table is not a double sound but aga...

Page 14: ...al should increase and eventually cut off The main thing is the noticeable increase in the signal tone and the decrease when you leave the target To be able to understand this you need over time with experience 5 Extending signal mineral signal If the signal does not stop at all but continues for a long time this is the sound from a mineral It may be longer in the Dly program It is usually caused ...

Page 15: ...ad small aluminum It will be useful for individualists Your chances of reaching the target that will save some inert metals will increase in the fields where only one coin gold is there In this mode soil effect small brick chips are removed Graphic Screen When you hold down the Gr Button for 2 seconds the bar screen closes and returns to the graphic display Whichever program you are in this does n...

Page 16: ...ns Dense mineral Bulk coins Bulk coins will usually value between 50 70 However it should be interpreted taking into account the sound separation If the sound is full signal is not doubled it should be considered If it gives a doubled sound it will be iron even if it gives this number range Between 00 75 00 99 Silver or copper coins over 7 grams are included in this group In addition bulky objects...

Page 17: ...r filter settings to 4 especially in urban environments near high voltages The parasite will drop 2 Magnetic and mineral effects of soil It is impossible to completely get rid of the mineral and magnetic effects in the soil The two biggest problems in the soil in pulse devices are that the device is affected by soil changes and dense tiles The tiles show an iron mineral effect Brick effect increas...

Page 18: ...eral stones and tiles will be greatly reduced But metalized slags cannot be expected to cut because this is the purpose of the metal detector Is it on the metal surface Is it deep 1 Examine the bar indicator on the screen Where you get a signal the bars are 1 2 levels and if the signal is a little wide it is deep 2 Hold the target with the big coil again with the small coil If it gives a strong si...

Page 19: ...l 100 CM 110 CM 120 CM 30X30 Steel metal 200 CM 240 CM 300 CM 50X50 METAL 250 CM 350 CM 400 CM GR1 GROUND GR1 AUTO3 sns5 fil3 trs7 Coils Metal Object 38 cm 45 cm 90cm coil 7grm Gold 22MM 27CM 27cm X Coin27 MM 33 CM 33cm X 10X10 Copper 80 cm 90 cm 110 CM 10x10 Coins 75CM 80 CM 90 CM 30X30 Steel METAL 150 CM 160 CM 190 CM 50X50 METAL 190CM 200 CM 225 CM Not In GR Program under soil test are deeper t...

Page 20: ...ll coils 4 If you cannot receive any signal with small coils you should confirm by using big coils If the signal is not received it could be mineral or brick pile If you receive stronger signals repeat the steps above You will get comfortable with this as you use the device Charging the battery Gold technology takes care to use the best selection for battery and its adapter because battery and cha...

Page 21: ...ansportation costs for sending the detector are the responsibility of the device owner The fact that this section is stamped by the company is a warranty certificate If the device will not be used for a long time recharge the battery pack every month Do not pick up the device when it is damp and keep away the device from humid conditions WARNING For the detection of mines and ammunition in the sec...

Page 22: ... Form The name of the owner Date Detector Model Serial No The seller company Buying Date Delivered piece s Address Telephone GSM Fax E mail Problem description Please write the problem that causes your device to not work ...

Page 23: ......

Reviews: