background image

I M P O RTA N T   S A F E T Y   I N S T RU C T I O N S

READ ALL INSTRUCTIONS BEFORE USE

3

English

WARNING

This symbol indicates the possibility of death or serious injury.

CAUTION

This symbol indicates the possibility of injury or damage to property.

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. Always read and
obey all safety messages.

This is the safety alert symbol. 

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “WARNING” or “CAUTION”. 
These words mean:

WARNING

To reduce the risk of fire, electric shock, or injury 

to persons when using this appliance, follow basic precautions, including the following:

• Do not attempt to repair or replace any part 

of your air conditioner unless it is specifically
recommended in this manual. All other services
should be referred to a qualified technician.

• If the power cord becomes worn or damaged,

the cord should only be replaced by a qualified
service technician using genuine replacement
parts.

• The air conditioner should be plugged into its

own grounded 15A, 60 Hz., 120 VAC circuit. 

• Do not plug other appliances into the same

outlet; it can overload the circuit and cause a fire
or electric shock. 

• Do not remove the round grounding prong from

the plug. It can result in the risk of electric shock. 

• This air conditioner is not designed for use by

young children. Young children should be
supervised to ensure that they do not play with
or climb on the air conditioner. 

• Be sure all packaging materials are removed

from the air conditioner before use. It can result
in personal injury.

• Do not disassemble or modify the air conditioner

or the power cord. It can result in the risk of
electric shock or fire.

• Do not place the power cord or air conditioner

near a heater, radiator, or other heat source. It
can result in the risk of electric shock or fire.

• Do not use this or any appliance near flammable

gases or liquids or other combustibles, such as
gasoline, benzene, thinner, etc. It can result in
the risk of electric shock or fire.

• Make sure the power cord is plugged firmly and

completely into the outlet. It can result in the risk
of electric shock or fire.

• Do not start or stop operation by plugging in or

unplugging the power cord. It can result in the
risk of electric shock.

• If the air conditioner is making unusual sounds or

is emitting smoke or an unusual odor, unplug it
immediately. It can result in the risk of electric
shock or fire.

• Do not use if the electrical socket is loose or

damaged. It can result in the risk of electric
shock or fire.

• Do not operate with wet hands or in a damp

environment. It can result in the risk of electric
shock.

• Do not use this or any electrical appliance if you

smell gas. It can result in the risk of fire or
explosion.

• Turn off and unplug the air conditioner before

cleaning to avoid the risk of electric shock.

• Do not clean the unit with water. Water can enter

the unit and damage the insulation, creating a
shock hazard. If water enters the unit, unplug it
immediately and contact Customer Service. It
can result in the risk of electric shock. 

• Use two or more people to lift and install the

unit. Failure to do so can cause back injury or
other injuries.

BASIC SAFETY PRECAUTIONS

Summary of Contents for GP120CE

Page 1: ...référence future Lisez et suivez toutes les règles et les instructions relatives à la sécurité avant d utiliser ce produit Model Modèle CLIMATISEUR MOBILE English Français To contact Goldstar 24 hours a day 7 days a week 1 800 243 0000 US 1 888 542 2623 Canada Or visit us on the Web at Pour contacter Goldstar 24 heures par jour 7 jours par semaine appelez le 1 800 243 0000 US 1 888 542 2623 Canada...

Page 2: ......

Page 3: ...n the air conditioner Be sure all packaging materials are removed from the air conditioner before use It can result in personal injury Do not disassemble or modify the air conditioner or the power cord It can result in the risk of electric shock or fire Do not place the power cord or air conditioner near a heater radiator or other heat source It can result in the risk of electric shock or fire Do ...

Page 4: ... not operate the air conditioner if the room temperature is below 18 C 65 F Do not position the air conditioner so that pets or house plants are exposed to the direct air flow It can result in the risk of injury to pets or house plants This air conditioner is designed for normal household use Do not use for cooling pets foods precision machinery or art objects Do not drink the water from the drain...

Page 5: ......

Page 6: ...onvenient grip when lifting the air conditioner The remote control allows you to adjust the temperature and operate most functions of the air conditioner from across the room Swiveling casters allow you to move the air conditioner easily on most floor surfaces Used when water is full or free of using long time Before moving the unit drain the internal water collection tank completely by using bott...

Page 7: ...eration of functions is the same when using the remote or the control panel unless otherwise stated POWER Operation begins when this button is pressed and stops when you press the button again MODE Press this button to select COOL DRY FAN mode FAN SPEED Adjusts the circulation fan speed between HIGH MID LOW fan speed TIMER Press this button to set TIMER ON TIMER OFF or NO TIME UP DOWN LCD Display ...

Page 8: ...e or objects that could block the vent openings Make sure that any items that could be blown over or damaged by the airflow from are out of the path BEFORE USING YOUR AIR CONDITIONER 3 Do not remain in the direct airflow from the air conditioner for extended periods of time To prevent damage or injury to pets and plants make sure they are not exposed to direct airflow from the air conditioner When...

Page 9: ...e only alkaline batteries Do not use rechargeable batteries When replacing batteries always replace both batteries with new batteries Do not mix old and new batteries If the air conditioner will not be used for an extended period of time remove the batteries from the remote Lift up the Control Panel Slide the Remote into place for storage 1 2 Remote Control Control Panel CAUTION 噝 If the liquid fr...

Page 10: ......

Page 11: ...the specification of this product Do not replace or prolong it with your own private hose as this could cause mal function WARNING 1 2 SELECTION OF INSTALLATION LOCATION Install the unit on a flat and dry place For best performance allow at least 50cm of air space on all sides of the unit for good air circulation ...

Page 12: ......

Page 13: ...nents are used for window venting Not all components are used for every installation EXHAUST COMPONENTS 13 4 Type A Screws 10 Type B Screws Security Bracket 1 Type B Foam Seal non adhesive 2 Type C Foam Seals Adhesive type Shorter Flexible Venting Hose Window Installation Kit includes 2 Window Vent Panel and 2 Extension Panels 2 Type A Foam Seals adhesive Vent Panel Small Extension Panel Large Ext...

Page 14: ... the large extension panel For window openings from 737mm to 914mm use the window vent panel and both extension panels Vent Panel 457mm 457mm Vent Panel 464mm 610mm Small extension panel Vent Panel Large extension panel Vent Panel Large extension panel Vent Panel 610mm 737mm Large extension panel Vent Panel 737mm 914mm Large extension panel Vent Panel Small extension panel Small extension panel 46...

Page 15: ...two extensions 6 type B screws Two vent panels and two extensions 9 type B screws Type B screws INSTALLATION IN VERTICAL SLIDING WINDOWS INSTALLATION IN VERTICAL SLIDING WINDOWS INSTALLATION INSTRUCTIONS English 4 Cut the foam seal B Non adhesive type to the window width Stuff the foam seal B between the glass and the window to prevent air and insects from getting into the room Extension panel if ...

Page 16: ...ecurity bracket with a type B screw as shown Type B screw Security Bracket INSTALLATION INSTRUCTIONS 16 6 Insert the oval end of the diffuser into the window installation kit until the locking tabs engage Secure in place with four Type A screws Type A screws ...

Page 17: ...m seal B Non adhesive type 4 Cut the foam seal B Non adhesive type to the window height Stuff the foam seal B between the glass and the window to prevent air and insects from getting into the room 3 Extension panel if required Vent Panel Type B screws 17 Carefully close the window Secure the vent panel in place with 4 type B screws plus one screw for each extension Vent panel only 4 type B screws ...

Page 18: ...e B screw Security bracket 18 6 Insert the oval end of the diffuser into the window installation kit until the locking tabs engage Secure in place with four of the included screws Type A screws Type B screw INSTALLATION INSTRUCTIONS INSTALLATION IN CASEMENT STYLE WINDOWS ...

Page 19: ...r personal injury WARNING 噝 噝 To prevent damage to the finishi do not use gasoline benzene thinner etc or any abrasive cleansers to clean the air conditioner the may damage the finish Never pour water onto or into the unit it could damage internal components and create a shock and fire hazard The air filter should be cleaned every two weeks depending on indoor air quality more frequent cleaning ma...

Page 20: ......

Page 21: ... air conditioner in a cool dry location away from direct sunlight extreme temperatures and excessive dust Remove the batteries from the remote Before using the air conditioner again Make sure the filter and drain cap are in place Check the cord to make sure it is in good condition with no cracks or damage Place new batteries in the remote Install the air conditioner as described in the Installatio...

Page 22: ... there is sufficient clearance around the not cool properly air conditioner and that the air inlet and outlet are not blocked by furniture curtains etc The air filter is dirty Clean the air filter at least every two weeks See the Care and Cleaning section The room is very hot or not enough When first turned on allow the air conditioner time allowed for cooling sufficient time to cool the room Cold...

Page 23: ...e auto stop protection Unit abnormal protection to avoid occurrence of unit damage KHQ FRLO VHQVRU IHHOV FRLO WHPSHUDWXUH LV ć the unit will stop and display E4 to defrost and fan speed is low KHQ FRLO WHPSHUDWXUH UXQV XS WR ć the unit will re cool TROUBLESHOOTING English 23 Cautions Switch off the unit and unplug it immediately if anything abnormal happens Then contact a qualified electrician ...

Page 24: ...TY DOES NOT APPLY TO 1 Service trips to your home to deliver and pickup install instruct or replace house fuses or connect house wiring or plumbing or correction of unauthorized repairs 2 Damage to the product caused by accident pest fire floods or acts of God 3 Repairs when your GOLDSTAR product is used in other that normal single family household use or contrary to the instructions outlined in t...

Page 25: ... d évent et panneaux d extension de fenêtre 3 Installation dans les fenêtres coulissant verticalement 3 S 3 Installation dans les fenêtres coulissant horizontalement 3 W Fonctionnement Avant d utiliser votre climatiseur 3X 3Y Utilisation des contrôles 3Z En cas de panne Avant d appeler le service 4 4 Garantie Information pour inscrire votre produit 4 Entretien et nettoyage Nettoyage du boîtier X N...

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ...nde vous permet d ajuster la température et de régler la plupart des fonctions de votre climatiseur à distance Un support de télécommande est inclus pour le rangement pratique Les poignées intégrées vous donnent une bonne prise pour soulever votre climatiseur Les roulettes pivotantes vous permettent de bouger votre climatiseur facilement sur la plupart des surfaces de planchers Avant d enlever l a...

Page 30: ...uton pour sélectionner le mode Cool Refroidissement Dry Séchage ou Fan Ventilation FAN SPEED vitesse du ventilateur TIMER Appuyez sur ce bouton pour mettre la minuterie en marche pour arrêter la minuterie ou pour fonctionner en mode sans minuterie UP DOWN HAUT BAS Afficheur ACL NOTE 3 Le réglage des fonctions est le même que l on utilise la télécommande ou le panneau de sauf autrement indiqué cont...

Page 31: ...aux plantes assurez vous qu ils ne sont pas exposés directement au courant d air en provenance de votre climatiseur Quand vous utilisez votre climatiseur en même temps qu une cuisinière une cheminée ou un autre appareil de combustion assurez vous que suffisamment d air frais entre dans la chambre N utilisez jamais votre climatiseur dans des espaces hermétiquement clos avec ce genre d appareils Ce ...

Page 32: ...s alcalines AAA neuves dans le compartiment à piles en vous assurant de respecter la bonne polarité Remettez le couvercle du compartiment à piles en vous assurant que le taquet de verrouillage cliquette en place NOTES Utilisez uniquement des piles alcalines N utilisez jamais de piles rechargeables Quand vous remplacez les piles remplacez toujours les deux piles par des piles neuves N e mélangez pa...

Page 33: ...lateur Lorsque l appareil est hors tension appuyez sur le bouton Timer Minuterie pour mettre la minuterie en marche Appuyez sur les boutons Up Haut ou Down Bas pour régler le temps de 30 minutes à 24 heures Le clignotant Timer on Minuterie en marche s allumera La température ne peut pas être réglée N utilisez pas la conduite d évacuation d air 5 Minuterie arrêtée Lorsque l appareil est sous tensio...

Page 34: ...rformance laisser de 50cm pouces de chaque côté de l appareil afin d assurer une bonne circulation d air 1 2 La longueur du tuyau d évacuation est conçue spécialement pour se conformer aux spécifications de ce produit ATTENTION Ne la remplacez pas ou ne la rallongez pas avec un autre tuyau car cela pourrait entraîner un fonctionnement incorrect 34 ...

Page 35: ...avec le tuyau installé Vous pouvez enlever le tuyau pour nettoyer ou ranger votre climatiseur le cas échéant Renversez les étapes ci dessous pour enlever le tuyau et le diffuseur Insérez l adaptateur situé à la grande extrémité du tuyau dans le trou situé à l arrière de votre climatiseur 35 Français ...

Page 36: ...és comme évents de fenêtre Tous les éléments ne sont pas utilisés pour chaque installation ÉLÉMENTS DE SORTIE Ensemble dʼinstallation de fenêtre comprend un panneau dʼévent de fenêtre et 2 panneaux dʼextension 4 vis de type A 10 vis de type B Support de sécurité 1 joint en mousse de type B non adhésif 2 joints en mousse de type A adhésif Panneau d évent Petit panneau d extension Grand panneau d ex...

Page 37: ...e de 464mm à 610 mm utilisez le panneau d évent de fenêtre et le petit panneau d extension Pour les ouvertures de fenêtre de 610mm à 737 737 utilisez le panneau d évent de fenêtre et le grand panneau d extension Pour les ouvertures de fenêtre de 737mm à 914 mm utilisez le panneau d évent de fenêtre et les deux panneaux d extension Panneau d évent Grand panneau d extension Panneau d évent Petit pan...

Page 38: ...itre et la fenêtre pour éviter de laisser l air et les insectes 2 Fermez soigneusement la fenêtre Fixez en place le panneau d évent à l aide de 4 vis de type B plus une vis pour chaque panneau d extension Panneau d évent uniquement 4 vis de type B Panneau d évent et un panneau d extension 5 vis de type B Panneau d évent et deux panneaux d extension 6 vis de type B Deux panneaux d évent et deux ext...

Page 39: ...support de sécurité à l aide d une vis de type B comme l indique la figure Vis de type B Support de sécurité Vis de type A 6 Insérez l extrémité ovale du diffuseur dans l ensemble d installation de la fenêtre jusqu à ce que les taquets de verrouillage entrent Fixez en place à l aide de quatre vis de type A 39 ...

Page 40: ...ilisez Extension panel if required Vent Panel Rain shield Type B screws Joints en Mousse B Non adhésif 4 Coupez le joint en mousse B non adhésif sur la hauteur de la fenêtre Insérez le joint B entre la vitre et la fenêtre pour éviter de laisser l air et les insectes Fermez soigneusement la fenêtre Fixez en place le panneau d évent à l aide de 4 vis de type B plus une vis pour chaque panneau d exte...

Page 41: ... INSTRUCTIONS D INSTALLATION Vis de type B Support de sécurité INSTALLATION DANS LES FENÊTRES COULISSANT HORIZONTALEMENT Insérez l extrémité ovale du diffuseur dans l ensemble d installation de la fenêtre jusqu à ce que les taquets de verrouillage entrent Fixez en place à l aide de quatre vis de type A comprises 41 ...

Page 42: ......

Page 43: ...erne d eau est plein l afficheur ACL clignotera P2 et l appareil s arrêtera automatiquement Quand le réservoir intérieur de collecte d eau est plein le climatiseur s arrête de fonctionner jusqu à ce que le réservoir soit vidé Débranchez le climatiseur débranchez le tuyau de sortie de l arrière et amenez le climatiseur dans un endroit qui convient pour la vidange ou à l extérieur Vous pouvez égalem...

Page 44: ...es et à la poussière Avant de se remettre à utiliser le climatiseur Assurez vous que le filtre et le capuchon du drain sont à leur place Vérifiez le cordon d alimentation pour vous assurer qu il est en bonne condition et qu i ne soit ni endommagé ni craqué Mettez des piles neuves dans la télécommande Installez votre climatiseur de la manière indiquée dans les Instructions d installation 1 2 3 X 2 ...

Page 45: ......

Page 46: ...ment de l appareil arrêt automatique Protection contre les anomalies de l appareil pour prévenir l endommagement de l appareil Lorsque le détecteur du serpentin détecte que la température du serpentin HVW GH HW OD YLWHVVH GX YHQWLODWHXU HVW EDVVH RUVTXH OD WHPSpUDWXUH GX VHUSHQWLQ DWWHLQW Attention Arrêtez l appareil et débranchez le immédiatement si quelque chose d anormal se passe Puis contactez...

Page 47: ...cement de service à domicile pour livrer ou cueillir installer instruire ou remplacer un fusible ou rebrancher le câblage résidentiel ou la plomberie ou corriger une réparation non autorisée 2 Aux dommages au produit causés par accident vermine incendie inondation ou actes de Dieu 3 Aux réparations lorsque le produit GOLDSTAR est utilisé à des fins autres que normales utilisation résidentielle uni...

Page 48: ...Printed in China ...

Reviews: