GOLDMUND T1000 NextGen - Universal Power Amplifier - 9
3
AMPLIFIER CONTROLS
3.1
MANUAL OPERATION
On the front plate of the GOLDMUND TELOS 1000 NextGen amplifier you will find only two
POWER keys.
The two POWER keys have to be activated simultaneously to power the amplifier on.
This security feature is provided to avoid accidental POWER ON or POWER OFF.
As soon as the amplifier is connected to mains power, the orange indicator on the front
panel will blink briefly every 3 seconds.
Push both buttons of the front panel simultaneously in order to turn on the amplifier.
As soon as the amplifier is fully powered the green indicator will light steadily and the menu
will be displayed.
If the digital input is not used, the orange led is off, showing there is no lock and the
amplifier remains muted until a lock is found. The led will turn on as soon as the TELOS
1000 NextGen receives a digital input.
In analog mode (XLR & RCA) the orange led is always on.
By pressing the right key once, the amplifier is put in Operate mode “Unmute”, by pressing
the right key once again, the amplifier returns to the menu “Muted” state.
The amp may be POWERED OFF by pressing the two POWER keys simultaneously at
anytime.
Power On Process:
•
Progressive charge of high power
capacitors to limit peak current on
AC line.
•
Switch on high power supply on
output stage.
•
Wait stabilization of high power
supply.
Power Off Process:
•
Push both buttons simultaneously
in order to turn off the amplifier.
•
As
soon
as
the
amplifier's
capacitor bank is fully discharged
the yellow indicator will blink briefly
every 3 seconds.