Goldmund Mimesis 15 User Manual Download Page 11

 

GOLDMUND MIMESIS 15 

– Acoustic Processor - 11 

REMOTE CONTROL 

 
Your Mimesis 15 has a built-in remote control for volume, balance and input selection. 
The Mute circuit can also be activated via the remote. To mute or un-mute the Mimesis 15 
with the remote, 

press the “MUTE/STBY” key briefly. 

To put the Mimesis 15 

in Standby mode, press the “MUTE/STBY” key continuously until the 

Mimesis 15 goes to Standby (indicated via the Standby Led on the front panel). 
 
The VOL+ and VOL- keys adjust the general volume. 
The  4  balance  keys  (for  details  on  the  remote  control  see  chapter  12,  p.16)  control  the 
Left/Right and Front/Rear balance, maintaining a constant overall volume.  
To  activate  this  balance  control,  first,  press  t

he  “BAL”  key  on  the  remote  control.  Then, 

adjust the balance, using the balance keys, Left/Right (4 & 6), Front/Rear (3 & 5) only with 
multichannel signal. 
Note: Adjustment can be done when the led on the “Bal. On” key is lit. 
 
Any RC5 coded remote-control emitter can control the Mimesis 15. The codes are available 
upon request. Most of the programmable transmitter units available have the capabilities to 
drive the Mimesis 15 as a standard digital processor, for all the specified functions. 
 

Note:

  The  Mimesis  15  can  be  controlled  by  the  iGoldmund  System,  please  refer  to  the 

iGoldmund manual for more detail. 
 
 
 

CLEANING

 

 
 
Always disconnect the power cord from the wall socket before cleaning your processor. 
To  clean  the  metal  of  the  processor,  always  use  a  very  soft,  clean,  damp  cloth  to  avoid 
scratching the surface. Dampen with water or a mild detergent solution. Avoid abrasive or 
harsh cleansers (e.g. products containing sodium carbonate). 
 
 
 
 
 

Summary of Contents for Mimesis 15

Page 1: ...USER MANUAL GOLDMUND MIMESIS15 Acoustic Processor...

Page 2: ...e reproduction of sound and image At Goldmund we strive to lead in the creation development and manufacture of the industry s most advanced technologies for audio and home theater systems The guiding...

Page 3: ...IES 5 2 UNPACKING 5 3 PROCESSOR LOCATION COOLING 6 4 POWER SUPPLY 6 5 FIRST INSTALLATION CONNECTIONS 7 6 HOME THEATER CONFIGURATION 10 7 FRONT PANEL FUNCTIONS 10 8 REMOTE CONTROL 11 9 CLEANING 11 10 T...

Page 4: ...nly careful use can provide all the satisfaction you are expecting All handling must be performed according to the following instructions to avoid deterioration of the processor Nevertheless if the in...

Page 5: ...keep the time integrity that the best systems may provide Goldmund recommends using the digital Goldmund Lineal cable Cables in special lengths can also be ordered from your retailer 2 UNPACKING You w...

Page 6: ...a shelf or on a piece of furniture where the processor is isolated from vibrations of mechanical components such as the CD transport itself You must also be careful to locate your Mimesis 15 in a ver...

Page 7: ...turned ON via the back panel power switch the unit accomplishes a self test run via its internal software then a software routine successively tests the modules inside the machine If any abnormal fun...

Page 8: ...sound quality of your audio system A standard configuration is available from the Goldmund Universal Configurator with corresponding speakers Please contact your authorized Goldmund retailer to assis...

Page 9: ...figuration loaded Please contact your authorized Goldmund retailer to assist you to set up your unit To play audio files from a computer to a Mimesis 15 1 Connect the USB cable from the computer to th...

Page 10: ...e contact your authorized Goldmund retailer for the configuration of your Mimesis 15 for home theater applications 7 FRONT PANEL FUNCTIONS 7 1 INPUT SOURCE SELECTION The back panel inputs are selected...

Page 11: ...on the remote control Then adjust the balance using the balance keys Left Right 4 6 Front Rear 3 5 only with multichannel signal Note Adjustment can be done when the led on the Bal On key is lit Any...

Page 12: ...l and remote control adjustable level control with 65dB range and 0 05dB accuracy in the 0 34dB range REMOTE CONTROL RC5 Standard remote system compatible with standard programmable remote control tra...

Page 13: ...250V slow blow SIZE AND WEIGHT 440 W x 404 D x 130 H mm Weight 12kg WARRANTY 3 years parts and labor Information and product specifications contained in this manual are subject to change without prio...

Page 14: ...rs heaters stoves or other appliances including amplifier that produce heat 9 Power sources Connect the appliance to a power supply only of the type described in the operating instructions or marked o...

Page 15: ...ation requirements 16 Unplug this apparatus during lightning storms or when unused for long periods of time 17 Objects and liquid entry Take care not to let objects or liquids fall into the product 18...

Page 16: ...ive Balance 2 Mute Standby 3 Front Balance 4 Left Balance 5 Rear Balance 6 Right Balance 7 Volume Up 8 Volume Down A Analog Input 1 B Analog Input 2 C Analog Input 3 D Digital Input 4 E Digital Input...

Reviews: