5. SPEAKER CONNECTIONS 

 
 

Usable in any type of configuration, the Logos Sub has a built-in amplifier with both 
analogue and digital inputs and a built-in input crossover.  
The amp connecting panel provides two additional switches to select the analogue or 
digital inputs and which channel of the SPDIF signal is used. 
The only connections needed are the Power cord and the interconnect linking the 
Logos Sub to the output of the preamplifier, or in digital, the digital link cable for 
SPDIF input.  
The Logos Sub may receive two analogue cables if one only one Subwoofer is used 
so the right and left channels may be mixed automatically inside the crossover. 
 

ATTENTION : If you use 2 Subwoofer in analogue, you have only one cable that 
can be connected to any of the two available RCA inputs. In such a case, 
always leave the unused input on each Logos Sub with a short-circuiting plug 
mounted

ATTENTION : In most configurations, the ground wire from AC plug must 
absolutely be lifted on all amplifiers and on the Logos Sub connection to the 
AC line. Otherwise a bad ground loop may make amplifiers oscillate and be 
destroyed. 

 
The Logos Sub is automatically powered ON when it receives modulation. 
For a Home-Theatre connection, several possibilities are accessible. 
The connection is different if the speakers are used in a multi-channel system or in a 
2 channels system : 

 
A. Connection in a Multi-Channel system : 

 
If used in a multi-channel system :  

  One Logos Sub may be connected to the Suwoofer channel, either in analogue or 

digital. 

  2 x Logos Sub may also be connected in parallel to the sub-woofer channel in 

analogue. 

  To match the Logos or Logos Mini speaker in frequency response, use the 

position 2 (center) of the crossover frequency adjustment. Level adjustment 
depends on the room acoustics.  

  The higher position of the crossover is set for higher crossover frequencies 

(around 80Hz). Do not use it for linear response but only to emphasize the low 
frequency effects.  

  The leftmost first position provides a 35Hz cutoff frequency and is used to 

complement a system based on the Goldmund Epilogue 1 speakers. 

 
 

Summary of Contents for LOGOS SUB

Page 1: ...THE GOLDMUND LOGOS SUB SUB BASS SPEAKER SYSTEM USER MANUAL ...

Page 2: ...THE GOLDMUND LOGOS SUB SUB BASS SPEAKER SYSTEM USER MANUAL ...

Page 3: ...nd use can provide the satisfaction you are expecting The installation instructions must be scrupulously carried out and the mentioned precautions taken to get the expected result and to avoid to deteriorate the speaker If the unused input is not short circuited properly as indicated below warranty does not apply Nevertheless if the instructions are perfectly carried out you will notice that the s...

Page 4: ...weight the Logos Sub may still be moved easily for acoustic setup Be only careful to not damage the grills which should be attached only when the speaker is set in its final position 3 SELECTING THE LOGOS SUB LOCATION A very rigid floor is very important for the optimal sonic result of your Logos Sub speaker Select a position of the speaker to have the most rigid possible coupling with the floor S...

Page 5: ...lug must absolutely be lifted on all amplifiers and on the Logos Sub connection to the AC line Otherwise a bad ground loop may make amplifiers oscillate and be destroyed The Logos Sub is automatically powered ON when it receives modulation For a Home Theatre connection several possibilities are accessible The connection is different if the speakers are used in a multi channel system or in a 2 chan...

Page 6: ... subwoofer in analogue connect one analogue input of the subwoofer to the right channel and the other to the left channel of the preamplifier Frequency adjustment see the above section 6 RUNNING IN FOR THE LOGOS SUB The Logos Sub like any other top quality speaker needs several days playing music before providing the top sonic quality it is built to provide The few first hours can be very frustrat...

Page 7: ...nd 25cm passive radiator mounted in phase Bandwidth Low Frequency Cutoff 21 Hz 3dB Electronic Crossover 3 separate low pass crossover frequencies 35Hz 50Hz 80Hz 24dB per octave slope Master level control Bass Load Passive radiator Size and Weight Weight of one sub woofer 40 kg Size of one sub woofer 32 cm H x 32 cm W x 32 cm D ...