background image

Model

 

GLS5-912GSB1-C2

Auxiliary

 

Semi

 

rapid

 

x2

Rapid

Wok

 

TOTAL

 

NHGC

 

NATURAL

 

GAS

 

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

UNIVERSAL

 

LPG

 

0

.

9

1

.

8

+

0

.

8

4

.

0

6

.

5

17

.

2

45

1

.

0

1

.

0

1

.

0

0

.

53

0

.

69

1

.

02

+

0

.

5

3

.

6

6

.

5

17

.

2

44

.

6

2

.

75

2

.

75

2

.

75

1

.

18

1

.

55

10

.

8

1

.

0

0

.

9

10

.

8

2

.

75

Model

 

GLS3-924GSB1

Auxiliary

 

Wok

 

x

 

2

 

TOTAL

 

NHGC

 

NATURAL

 

GAS

 

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

UNIVERSAL

 

LPG

 

0

.

9

1.8+0.8

4

.

0

17

.

2

38.4

1

.

0

1

.

0

0

.

53

1.02+0.5

3

.

6

17.2

38

2

.

75

2

.

75

Model

 

GLS2-923GSB1

 Wok

TOTAL

 

NHGC

 

NATURAL

 

GAS

 

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

UNIVERSAL

 

LPG

 

1.8+0.8

17

.

2

34.4

1.02+0.5

17.2
34.4

1

.

0

2

.

75

Model

 

GLS4-619GSB1-C2

Auxiliary

 

Semi

 

rapid

 

x2

Wok

 

TOTAL

 

NHGC

 

NATURAL

 

GAS

 

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

UNIVERSAL

 

LPG

 

0

.

9

1

.

18

1

.

8

+

0

.

8

4

.

0

6

.

5

17

.

2

34

.

2

1

.

0

1

.

0

1

.

0

0

.

53

0

.

69

1

.

02

+

0

.

5

3

.

6

6

.

5

17

.

2

33

.

8

2

.

75

2

.

75

2

.

75

Model

 

GLS4-919GSB2-C1
GLS4-919GSB2-C2

Auxiliary

 

Semi

 

rapid

Rapid

Wok

 

TOTAL

 

NHGC

 

NATURAL

 

GAS

 

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

Injector

 

Dia

(

mm

)

MJ

/

h

Test

 

point

 

kPa

UNIVERSAL

 

LPG

 

0

.

9

1

.

18

1

.

8

+

0

.

8

4

.

0

6

.

5

17

.

2

38

.

5

1

.

0

1

.

0

1

.

0

0

.

53

0

.

69

1

.

02

+

0

.

5

3

.

6

6

.

5

17

.

2

38

.

1

2

.

75

2

.

75

2

.

75

1

.

55

10

.

8

1

.

0

0

.

9

10

.

8

2

.

75

Description

Explanation

Zone

 

indicators

These

 

show

 

which

 

zone

 

is

 

under

 

control

.

Flame

 

power

Flame

 

power

 

of

 

the

 

zones

,         

is

 

the

 

lowest

 

and

          

is

 

the

 

highest

The

 

hotplates

 

are

 

fitted

 

with

 

mains

 

powered

 

electronic

 

spark

 

ignitors

so

 

must

 

be

 

connected

 

to

 

mains

 

power

 

supply

 (

i

.

e

nominal

 

220

 - 

240

 

V

 

ac

to

 

operate

If

 

power

 

is

 

not

 

available

the

 

hotplate

 

will

 

still

 

work

 

but

 

the

 

burners

 

will

 

have

 

to

 

be

 

lit

 

with

 

a

 

match

 

or

 

similar

Depressing

 

the

 

gas

 

control

 

knob

 

of

 

any

 

burner

 

will

 

activate

 

the

 

spark

 

ignition

 

for

 

all

 

burners

To

 

light

 

the

 

burner

turn

 

the

 

gas

 

control

 

knob

 

to

 

the

 

High

 

Flame

 

setting

 

of

 

the

 

burner

 

to

 

be

 

lit

while

 

at

 

the

 

same

 

time

 

depressing

 

the

 

gas

 

control

 

knob

 

to

 

activate

 

the

 

spark

 

ignition

Once

 

the

 

burner

 

is

 

alight

 

continue

 

to

 

depress

 

the

 

gas

 

control

 

knob

 

for

 

5

 – 

10

 

seconds

 

to

 

allow

 

the

 

flame

 

safeguard

 

to

 

activate

If

 

when

 

you

 

release

 

the

 

gas

 

control

 

knob

the

 

burner

 

flame

 

goes

 

out

 

the

 

flame

 

safeguard

 

has

 

not

 

heated

 

up

 

enough

 

so

 

repeat

 

the

 

ignition

 

procedure

 

after

 

waiting

 

1

 

minute

 

for

 

gas

 

to

 

disperse

If

 

problems

 

with

 

burner

 

lighting

 

persist

refer

 

to

 

the

 

TROUBLESHOOTING

 

section

 

of

 

these

 

instructions

If

 

power

 

is

 

not

 

available

light

 

a

 

match

 

or

 

similar

then

 

turn

 

the

 

gas

 

control

 

knob

 

for

 

the

 

burner

 

to

 

be

 

lit

to

 

the

 

High

 

Flame

 

setting

Once

 

again

 

if

 

problems

 

with

 

burner

 

lighting

 

persist

refer

 

to

 

the

 

TROUBLESHOOTING

 

section

 

of

 

these

 

instructions

When

 

burner

 

lights

adjust

 

desired

 

flame

 

height

On

 

finishing

turn

 

control

 

knob

 

to

 

off

 

position

 

marked

 

with

 

a

 

black

 

DOT

BURNER

 

AND

 

UTENSIL

 

CHOICE

The

 

maximum

 

utensil

 (

pan

diameters

 

in

 

millimetres

 (

mm

for

 

each

 

burner

 

are

1

For

 

Natural

 

Gas

 

hotplates

 

 Auxiliary

 (

small

and

 

Semi

-

Rapid

 (

medium

) = 

195

 

mm

 

 Rapid

 (

large

) = 

230

 

mm

 

 DCC

 (

wok

) = 

300

 

mm

 

2

For

 

Universal

 

LPG

 

hotplates

 

 Auxiliary

 (

small

), 

Semi

-

Rapid

 (

medium

and

 

Rapid

 (

large

) = 

195

 

mm

 

 DCC

 (

wok

) = 

300

 

mm

 

Issue Date :- 23/05/2017

Issue Date :- 23/05/2017

Start using your appliance

Summary of Contents for GLS2-923GSB1

Page 1: ...contains important information including safety installation points which will enable you to get the most out of your appliance Please keep it in a safe place so that it is easily available for future...

Page 2: ...dren who because of their physical sensory or mental capabilities or their inexperience or ignorance are not able to use the device safely should not use this device without supervision or instruction...

Page 3: ...g onto it The edge of the glass ceramic can be damaged by being knocked by the cookware Cookware made of cast iron cast aluminum or with damaged bottoms can scratch the glass toughened if pushed acros...

Page 4: ...pid Burner Aux Auxiliary Burner Tempered glass Trivet Control knobs Wok R Aux SR 3 Tempered glass Trivet Control knobs Model No Wok Wok Burner R Rapid Burner SR SemiRapid Burner Aux Auxiliary Burner W...

Page 5: ...installation Before cutting into any bench tops ensure the minimum clearances to walls adjacent surfaces and overhead surfaces required by the relevant gas appliance installation code see above will c...

Page 6: ...se outlet GPO in accordance with relevant electrical standards and or codes of practice applicable The power supply cord supplied must not touch against any hot surfaces and must be placed so that its...

Page 7: ...orised personnel may convert the hotplate from Natural gas to Universal LPG or from Universal LPG to Natural gas Contact the manufacturer or agent as required Wiring diagram for 5 Gas connection Insta...

Page 8: ...ronic spark ignitors so must be connected to mains power supply i e nominal 220 240 V ac to operate If power is not available the hotplate will still work but the burners will have to be lit with a ma...

Page 9: ...PANEL e to W a to TRIVETS UTENSIL SUPPORTS a a BURNERS W a a item to S T S T Wok it Gas Conversion ULPG NG kit The ULPG to NG conversion kit contains T Jet 0 9mm Semi Rapid Jet 1 18mm Rapid Jet 1 55mm...

Page 10: ...tains T T 0 53mm Semi Rapid Jet 0 69mm Rapid Jet 0 9mm Wok Jet 0 50mm IN 1 02mm OUT Converting to a gas type to T kit a 2 to 2 Changing the jets 1 2 a to kit 3 kit to Setting the minimum level 1 2 3 t...

Page 11: ...Semi rapid Rapid Wok 0 90 1 18 1 55 0 8 1 8 4 0MJ h 6 5MJ h 10 8MJ h 17 2MJ h 34 4 38 4 34 2 45 38 5 38 5 31 FAULT POSSIBLE CAUSE REMEDY Check plugged in and switched on Check mains circuit breaker C...

Page 12: ...of acceptable quality and the failure does not amount to a major failure 1 8 You must provide proof of your purchase of the Goldline product and the date of purchase in order to obtain the benefit of...

Reviews: