Model
GLS5-912GSB1-C2
Auxiliary
Semi
rapid
x2
Rapid
Wok
TOTAL
NHGC
NATURAL
GAS
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
UNIVERSAL
LPG
0
.
9
1
.
8
+
0
.
8
4
.
0
6
.
5
17
.
2
45
1
.
0
1
.
0
1
.
0
0
.
53
0
.
69
1
.
02
+
0
.
5
3
.
6
6
.
5
17
.
2
44
.
6
2
.
75
2
.
75
2
.
75
1
.
18
1
.
55
10
.
8
1
.
0
0
.
9
10
.
8
2
.
75
Model
GLS3-924GSB1
Auxiliary
Wok
x
2
TOTAL
NHGC
NATURAL
GAS
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
UNIVERSAL
LPG
0
.
9
1.8+0.8
4
.
0
17
.
2
38.4
1
.
0
1
.
0
0
.
53
1.02+0.5
3
.
6
17.2
38
2
.
75
2
.
75
Model
GLS2-923GSB1
Wok
TOTAL
NHGC
NATURAL
GAS
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
UNIVERSAL
LPG
1.8+0.8
17
.
2
34.4
1.02+0.5
17.2
34.4
1
.
0
2
.
75
Model
GLS4-619GSB1-C2
Auxiliary
Semi
rapid
x2
Wok
TOTAL
NHGC
NATURAL
GAS
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
UNIVERSAL
LPG
0
.
9
1
.
18
1
.
8
+
0
.
8
4
.
0
6
.
5
17
.
2
34
.
2
1
.
0
1
.
0
1
.
0
0
.
53
0
.
69
1
.
02
+
0
.
5
3
.
6
6
.
5
17
.
2
33
.
8
2
.
75
2
.
75
2
.
75
Model
GLS4-919GSB2-C1
GLS4-919GSB2-C2
Auxiliary
Semi
rapid
Rapid
Wok
TOTAL
NHGC
NATURAL
GAS
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
Injector
Dia
(
mm
)
MJ
/
h
Test
point
kPa
UNIVERSAL
LPG
0
.
9
1
.
18
1
.
8
+
0
.
8
4
.
0
6
.
5
17
.
2
38
.
5
1
.
0
1
.
0
1
.
0
0
.
53
0
.
69
1
.
02
+
0
.
5
3
.
6
6
.
5
17
.
2
38
.
1
2
.
75
2
.
75
2
.
75
1
.
55
10
.
8
1
.
0
0
.
9
10
.
8
2
.
75
Description
Explanation
Zone
indicators
These
show
which
zone
is
under
control
.
Flame
power
Flame
power
of
the
zones
,
is
the
lowest
and
is
the
highest
.
The
hotplates
are
fitted
with
mains
powered
electronic
spark
ignitors
,
so
must
be
connected
to
mains
power
supply
(
i
.
e
.
nominal
220
-
240
V
ac
)
to
operate
.
If
power
is
not
available
,
the
hotplate
will
still
work
but
the
burners
will
have
to
be
lit
with
a
match
or
similar
.
Depressing
the
gas
control
knob
of
any
burner
will
activate
the
spark
ignition
for
all
burners
.
To
light
the
burner
,
turn
the
gas
control
knob
to
the
High
Flame
setting
of
the
burner
to
be
lit
,
while
at
the
same
time
depressing
the
gas
control
knob
to
activate
the
spark
ignition
.
Once
the
burner
is
alight
continue
to
depress
the
gas
control
knob
for
5
–
10
seconds
to
allow
the
flame
safeguard
to
activate
.
If
when
you
release
the
gas
control
knob
,
the
burner
flame
goes
out
the
flame
safeguard
has
not
heated
up
enough
so
repeat
the
ignition
procedure
after
waiting
1
minute
for
gas
to
disperse
.
If
problems
with
burner
lighting
persist
,
refer
to
the
TROUBLESHOOTING
section
of
these
instructions
.
If
power
is
not
available
,
light
a
match
or
similar
,
then
turn
the
gas
control
knob
for
the
burner
to
be
lit
,
to
the
High
Flame
setting
.
Once
again
if
problems
with
burner
lighting
persist
,
refer
to
the
TROUBLESHOOTING
section
of
these
instructions
.
When
burner
lights
,
adjust
desired
flame
height
.
On
finishing
,
turn
control
knob
to
off
position
marked
with
a
black
DOT
.
BURNER
AND
UTENSIL
CHOICE
The
maximum
utensil
(
pan
)
diameters
in
millimetres
(
mm
)
for
each
burner
are
:
1
.
For
Natural
Gas
hotplates
Auxiliary
(
small
)
and
Semi
-
Rapid
(
medium
) =
195
mm
Rapid
(
large
) =
230
mm
DCC
(
wok
) =
300
mm
2
.
For
Universal
LPG
hotplates
Auxiliary
(
small
),
Semi
-
Rapid
(
medium
)
and
Rapid
(
large
) =
195
mm
DCC
(
wok
) =
300
mm
Issue Date :- 23/05/2017
Issue Date :- 23/05/2017
Start using your appliance