www.goldenseauv.com
11
11. Troubleshooting Tips
11.1 What to do if the device doesn’t work?
1. Ensure the device is plugged into a working wall socket.
2. Ensure the plug is wired correctly and terminal well-connected.
3. If you still have issues with the device, please contact your local dealer or our
customer service for assistance.
11.2 How often should the UV tube be replaced?
1. The UV tube is the core of the product, it should be replaced after 9000 hours of use
to maintain the germicidal efficacy.
2. The UV tube is defected if it flashes, please contact your local dealer or our customer
service to order a new UV tube. For replacing the UV tube, please refer to the
instructions in this user manual.
3. After use for a period of time, it is normal to find some black spots on both sides of
the UV tube.
11.3 The Audio alarm signal and LED indicator signal for this product:
Status
Audio Alarm
Power Indicator
Standby
-
Green indicator on
Delayed
Start
Beeping for 2 minutes regularly
(frequency increase in the
countdown 10 seconds)
Red indicator flashing for 2 minutes
regularly (frequency increase in the
countdown 10 seconds)
Lamp
Strike
UV Lamp on after 15 seconds
when the beeping stops
Red indicator on after beeping stops
Emitting
(working)
Single Beeping every 10 seconds Red indicator on
Motion
Detected
Dual beeping every 10 seconds
Red & Green indicators flashing
End of
Cycle
Triple beeping every 10 seconds
(in 30 seconds)
Green indicator on
Summary of Contents for UVL220