SUGGESTED PULSE SETTINGS
The chart below lists approximate pulses necessary to penetrate various materials. Settings vary greatly depend-
ing on imaging system used. Refer to imaging system instructions for more information.
The following is true when using film or digital systems that generate a positive image. If the radiograph is too
dark, the film is underexposed. If the radiograph is too light the film is overexposed. Underexposure can be cor-
rected by increasing the number of pulses and/or decreasing the distance between the imaging medium and the
XRS4. Overexposure can be corrected by reducing the number of pulses and/or increasing the distance between
the imaging medium and XRS4.
MATERIAL
PULSE SETTING
(24” BETWEEN X-RAY & IMAGER)
CARDBOARD / LIGHT WOOD / PLASTIC
2
LIGHT METAL
5-10
STEEL 1/4”
25
STEEL ½”
50
STEEL 1”
99
BRASS 1/8” to ¼”
50-99
Underexposed
Overexposed
Correct exposures (pulse setting)