background image

INSTALLATION AND OPERATING INSTRUCTIONS

GOLDEN BLOUNT

EL GRANDE

MODEL HD5030-TV TOP-VENT FIREPLACE

CSA APPROVED FOR NATURAL GAS OR PROPANE GAS

IMPORTANT!  Read all instructions carefully before starting

installation.  Failure to follow these instructions may result in

property damage, personal injury or possible loss of life.

WARNING: If the information in these
instructions is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
death.

– Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

 – WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.

• Do not touch any electrical switch;

do not use any phone in your
building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions.

• If you cannot reach your gas

supplier, call the fire department.

– Installation and service must be

performed by a qualified installer,
service agency or the gas supplier.

The Flue Damper must be in the full
open position when burning the gas
logs.

This fireplace is to be burned only with
the gas log set supplied with the
fireplace.  Burning other items could
cause a fire hazard or injury.

For best results, Natural Gas pressure
should be 7" to 12" W.C. and 11" W.C.
for Propane Gas.

To simulate real wood burning, the gas
burner is designed to burn a yellow
flame.  It is normal for the logs to soot-
up.  The soot can be easily removed
with a vacuum cleaner or soft brush.

Check the label on the firebox to
assure the proper gas type.  Never
use anything but the correct gas type
for your fireplace.

This appliance complies with National
Safety and is tested and listed to ANSI
Z21.50A - 1998  as Vented Gas fireplaces.
Installation must conform to local codes.
In the absence of local codes,  installation
must conform with the current National
Fuel Gas Code, ANSI Z223.1.

Massachusetts State Code requires
damper to be welded open or removed.

9/05

MANUFACTURED BY:

4301 WESTGROVE DRIVE

ADDISON, TX  75001

INSTALLER/CONSUMER RETAIN THIS APPLIANCE

MANUAL WITH THE INSTALLED APPLIANCE

Summary of Contents for EL GRANDE HD5030-TV

Page 1: ...ualified installer service agency or the gas supplier The Flue Damper must be in the full open position when burning the gas logs This fireplace is to be burned only with the gas log set supplied with the fireplace Burning other items could cause a fire hazard or injury For best results Natural Gas pressure should be 7 to 12 W C and 11 W C for Propane Gas To simulate real wood burning the gas burn...

Page 2: ...odes and Safety Standards 4 Piping and Gas Pressure Requirements 5 Installation Instructions 6 Log Placement 11 Operating Guidelines 13 Lighting Instructions 15 Trouble Shooting 17 Replacement Parts 19 2 INSIDE ROOM FLUSH MOUNT CHASE CORNER MOUNT 44 INSTALLATION OPTIONS Figure 2 1 ...

Page 3: ...D5030 TV TOP VENT FIREPLACE INTERIOR VIEW Pan Burner Outside Air Control Knob Damper Control Lever Pilot Light Valve Access Panel 3 Gas Line Access Outside Air Port Outside Air Control Knob On Off Switch ...

Page 4: ...D REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC IT IS IMPERATIVE THAT THE UNITS CONTROL COMPARTMENT BURNERS AND CIRCULATING AIR PASSAGE WAYS BE KEPT CLEAN TO PROVIDE ADEQUATE COMBUSTION AND VENTILA...

Page 5: ...OPERATION OF THIS UNIT ON LP GAS WITHOUT AN APPROVED REGULATOR AT THE TANK WILL LEAD TO GAS LEAKS AT THE CONTROL VALVE WITH POSSIBLE FIRE OR EXPLOSION Include a manual shut off valve and union in the line so the control or heater may be disconnected for servicing Include a drip leg and a plugged 1 8 N P T tapping into the line also The tapping must be accessible for the test gauge connection immed...

Page 6: ...it If the fireplace is to be installed on carpeting tile or other combustible material other than wood flooring the fireplace must be placed upon a metal or wood panel extend ing the full width and depth of the unit Fireplace framing can be built before or after the fireplace is set in place Framing should be positioned to accommodate wall covering and fireplace facing material The fireplace frami...

Page 7: ... at least 36 above the highest point of the roof opening see below 3 The 10 Rule of Thumb is a guide for calculating chimney height that works under most conditions However many factors can cause the need for additional chimney height beyond what 10 Rule of Thumb would indicate Topographical factors can cause high pressure zones which prevent a chimney from drawing This can occur if the house is l...

Page 8: ...nished wall and the fireplace surround Top and Sides can only be sealed with non combustible material Only non combustible material can be applied as facing to the fireplace surround Figure 8 2 Hearth Extension A Hearth Extension may be installed But it is not required for vented gas fireplaces 8 STUD FINISHED WALL NON COMBUSTIBLE SEAL JOINT MANTLE 12 MIN TOP OF OPENING Figure 8 2 CONTROL KNOB DUC...

Page 9: ... and reattach clip with 2 screws 2 Locate left panel retaining clip and remove 2 screws and set clip and screws aside Position left panel against left wall and reattach clip with 2 screws 3 Repeat Step 2 for right panel installation EXHAUST DIVERTER INSTALLATION The Exhaust Diverter prevents exhaust gases from entering the room 1 Locate screws attached to front side top of interior firebox and rem...

Page 10: ... Spread glowing embers over main burner pan and CEBB tube Note Be sure to create a gap between the main burner pan s glowing embers thus enhancing a front curl of flame from the main burner 4 Pour black rock around sides of pan for picture frame effect Note On L P models be careful not to pour black rock over brass air mixer attached to burner pan 5 Position log grate against rear wall of fireplac...

Page 11: ...LOG PLACEMENT FOR MODEL HD5030 TV LOG SET STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 11 ...

Page 12: ...STEP 7 STEP 8 FINAL ARRANGEMENT 12 ...

Page 13: ...ELINES Upon completing the gas line connection WARNING CHILDREN AND ADULTS SHOULD a small amount of air will be in the lines BE ALERTED TO THE HAZARDS OF HIGH When first lighting the pilot light it will SURFACE TEMPERATURE AND SHOULD STAY take a few minutes for the lines to purge AWAY TO AVOID BURNS OR CLOTHING themselves of this air Once the purging IGNITION YOUNG CHILDREN SHOULD BE is complete t...

Page 14: ...haracteristics is necessary CAUTION THE LOGS CAN GET VERY HOT HANDLE ONLY WHEN COOL MAINTENANCE INSTRUCTIONS IMPORTANT THE APPLIANCE AREA MUST BE KEPT CLEAR AND FREE FROM COMBUSTIBLE MATERIALS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS Visually inspect pilot periodically Brush or blow away any dust or linen accumulations If pilot orifice is plugged disassembly may be required to remove any fo...

Page 15: ...ss controls open valve access panel 3 Turn the control to the OFF position To do this you must turn the knob clockwise to the pilot position and then press in and continue turning clockwise to the OFF position 4 WAIT FIVE 5 MINUTES TO CLEAR OUT ANY GAS If you then smell gas STOP Follow B in the safety information above If you don t smell gas go to next step 5 The pilot does not require accessing f...

Page 16: ... Telephone gas company and fire department Ask instructions Before hanging up give your name address and phone number DO NOT go back into building If your L P tank runs out of fuel turn off gas at the appliance After L P tank Is refilled appliance must be re lit according to manufacturer s instructions If the gas control has been exposed to WATER in any way DO NOT try to use it It must be replaced...

Page 17: ...at electrode off pilot and trigger the red button again If pilot lights an improper gas air mixture caused the bad lighting and a longer purge period is recom mended If pilot will not light check gap at electrode and pilot should be 1 8 inch to have a strong spark If OK replace pilot C No gas or low gas 1 Check remote shut off pressure valves from fireplace Usually there is a valve near the firepl...

Page 18: ...nd TP terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position pilot lit and ON OFF switch OFF Replace faulty generator if reading is below specified minimum B Defective valve 1 Connect the millivolt meter probes to the TH TP and TP terminals on the gas valve Turn knob to pilot position depress and light pilot light If meter reading is greater ...

Page 19: ...lve knob to ON Place ON OFF switch to ON Check with millivolt meter at generator terminals Millivolt meter should read greater than 100 m v If the reading is OK and the burner does not come on replace the gas valve E Plugged burner orifice 1 Check burner orifice for stoppage and remove F Wall switch or wires 1 Follow corrective action in A 1 defective above check switch and wiring Replace where de...

Page 20: ...mopile 26 HD 126 Volcanic Rock 10 HD 110 Pilot Assembly Bracket 27 HD 127 Temp Limit Switch 11 HD 111 Burner Orifice NAT 28 HD 128 Damper Switch 12 HD 112 Burner Orifice LP 29 HD 129 Silica Sand NAT 13 HD 113 Burner Pan Assembly 30 HD 130 Glowing Embers 14 HD 114 Log Grate Optional Parts Specify Finish 15 HD 115 Step 1 Left Log 31 HD 131 Left Glassdoor Bifold 16 HD 116 Step 1 Right Log 32 HD 132 R...

Page 21: ... FIRST YEAR AFTER INSTALLA TION GOLDEN BLOUNT MAY DISCHARGE ITS ENTIRE WARRANTY LIABILITY BY REFUNDING THE PRICE OF THE PRODUCT PRODUCTS MADE BY OTHER MANUFACTURERS SOLD WITH THE FIREPLACE OR THEREAFTER ARE NOT COVERED BY THIS LIMITED WARRANTY THE USE OF OTHER UNAUTHORIZED COMPO NENTS WILL MAKE THIS WARRANTY NULL AND VOID THIS LIMITED WARRANTY WILL BE VOID IF THE APPLIANCE IS NOT INSTALLED BY A QU...

Reviews: